• 제목/요약/키워드: pressure waveform

검색결과 160건 처리시간 0.025초

3차원 로봇 맥 영상 분석기의 5단계 가압 맥파 분석에 의한 고혈압 환자의 현맥(弦脈) 연구 (A study on wiry pulse in hypertensive patients analyzed at 5 levels of applied pressure using 3 dimensional pulse imaging analyzer)

  • 강희정;권영상;김달래;김경철;임윤경
    • Korean Journal of Acupuncture
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2010
  • Objectives: The purpose of this study is to gain the objective indicators for the classification of hypertension by oriental medical pulse diagnosis, through finding out the parameters which can distinguish the pulse of hypertensive patient from that of normal subject, and characterizes the wiry pulse of hypertension. Methods: 30-59 yr, male, 946 healthy volunteers and 35 hypertensive patients were enrolled in this study. All the hypertensive patients were taking medicine to control the blood pressure and the blood pressure of the hypertension group was not statistically different from that of the normal healthy group. Data were acquired using 3 dimensional pulse imaging analyser(DMP-3000, DAEYOMEDI, KOREA) and analysed according to the age bands and the applied pressure levels. Results: 1. RAI/t, w/t and t2/t decreased with the levels of applied pressure and increased with age in the normal healthy group, not in the hypertension group. 2. RAI/t, w/t, t2/t were significantly higher in the hypertension group than the normal healthy group in the 30-age band, and elasticity coefficient was higher in the hypertension group than the normal healthy group in the 40-age band. 3. Researches on the patients without hypotensive agents are needed to figure out whether these parameters are the components of hypertensive wiry pulse. Conclusions: Analysing the radial pulse at 5 applied pressure levels using 3 dimensional pulse imaging analyser may be useful to differentiate the pulses of the hypertensive patients from those of the normal subjects, and characterize the hypertension.

실측진동파형을 이용한 비탈면 발파진동 해석 사례 (A Case Study on the Blasting Analysis of Slope Using Monitored Vibration Waveform)

  • 박도현;조영곤;전석원
    • 화약ㆍ발파
    • /
    • 제24권2호
    • /
    • pp.41-50
    • /
    • 2006
  • 화약을 이용한 지반굴착은 진동 및 소음 등의 공해가 필연적으로 수반되기 때문에 민원발생 및 주변 구조물에 영향을 미칠 수 있다. 특히, 발파작업 구간 부근에 지장물이 위치하게 되는 경우, 발파진동에 대한 안정성 평가는 매우 중요한 항목이 된다 발파진동안정성 평가 시 기존에는 시험발파를 통하여 대상지역의 발파진동식을 추정하고, 거리 및 장약량을 고려한 단순평가법이 많이 사용되어 왔으나, 이는 대상지역의 지형 및 지반조건을 현실적으로 고려하지 못한 방법이다 이를 보완하기 위해 최근에는 대상지역의 지형 및 지반조건을 연속체 또는 불연속체로 모사한 동적수치해석법이 적용되고 있다. 일반적으로 터널이나 비탈면 발파진동 수치해석시에는 다수의 발파공 모델링이 현실적으로 거의 불가능하여, 단일발파공, 특히 심발공에서 추정된 발파압력을 최종 굴착면에서의 등가압력으로 환산하여 발파하중으로 적용하게 된다. 이와 같은 이론적인 계산식이나 경험식에 의해 추정된 발파압력을 이용한 방법은 단일 발파공에서의 폭발압력에 대해 연구된 결과로서, 폭발상태를 이상적인 것으로 가정하고 폭발에너지를 구하게 된다. 따라서, 최종 굴착면에 적용된 등가압력은 지반조건을 고려하지 못하여 동일한 단면 및 발파조건에서는 동일한 발파하중이 산정된다. 즉, 기존의 발파하중 산정법은 대상지역의 지반조건을 고려하지 못하여, 해석결과의 신뢰도를 저하시키는 원인이 된다. 본 사례연구에서는 발파하중 산정 및 해석결과의 신뢰도를 제고하기 위하여, 대상지역의 시험발파시 획득된 실측진동파형을 이용한 발파하중 산정법을 통하여 비탈면 발파굴착시 주변 지장물의 안정성 평가를 수행하였다.

공명 발성, 악센트 기법 및 혀끝 트릴에 대한 전기성문파형과 공기역학적 특성 비교 (Comparisons of Aerodynamic and EGG Waveform Characteristics Under Resonant Voice, Accent Method, and Tongue-tip Trills)

  • 송윤경;심현섭;최홍식
    • 대한후두음성언어의학회지
    • /
    • 제11권2호
    • /
    • pp.146-160
    • /
    • 2000
  • The current study aimed to establish rationales for using three different voice therapies (resonant voice, accent method, and tongue-tip trills) by comparing the aerodynamic, and vocal fold closure characteristics under three therapies. A total of 8 male under/graduate students(tenors) participated as subjects. In order to compare aerodynamic characteristics, air flow rates and subglottal pressures were measured using Phonatory function analyzer under three therapy conditions. The characteristics of vocal fold closure patterns also were examined by comparing closed quotients(CQ) measured by Electroglottograph(EGG) under three therapy conditions. However, maximum phonation time (MPT) was measured under only resonant voice and tongue-tip trills using Aerophone II. The results are summarized as follows : 1) CQ, subglottal pressure and MPT decreased significantly under resonant voice as compared with throat voice, but the air flow rate increased significantly under resonant voice. 2) CQ decreased significantly under accent method as compared with throat voice, but both air flow rate and subglottal pressure increased significantly under accent method. 3) Both CQ and MPT decreased significantly under tongue tip trills as compared with throat voice, but air flow rate and subglottal pressure increased significantly under tongue-tip trills. Clinical implications of results were discussed in light of differential effects of three voice therapies.

  • PDF

불평등전계중에서 임펄스전압에 대한 $SF_6$ 기체의 전구방전과정의 분석 (Analysis of Predischarge Processes of $SF_6$ Gas Stressed by lmpulse Voltages under Nonuniform Electric Field)

  • 이복희;이경옥;이창준;백승권
    • 한국전기전자재료학회논문지
    • /
    • 제13권1호
    • /
    • pp.85-93
    • /
    • 2000
  • In this paper, the predischarge propagation processes of SF\ulcorner gas stressed by impulse voltages under nonuniform electric field perturbed by a needle protrusion are described. The statistical and formative time-lags and the time interval between leader pulses were investigated on the basis of the predischarge current measured in the gas pressure range of 0.1~0.5 MPa. The predischarge current is closely related to the waveform, amplitude and polarity of applied votages, the gas pressure and the gap geometry. Both the positive and negative predischarge processes in nonuniform electric field develop in a regime of stepwise leader propagation leading to electrical breakdown. The mean of the time interval between leader pulses gives about a factor of 10 higher for the negative than for the positive leader current puls-es. According as the gas pressure increases, the statistical time-lag was almost unchangeable, but the formative time-lag was gradually decreased.

  • PDF

버퍼의 넓이가 다른 스너버의 수치해석 비교 (The CFD Analysis Comparison of Several Snubbers with different Buffer Width)

  • 이경환;심규진;이용훈;정한식;정효민
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.38-43
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. The system usually comprises bottle volume, called snubber. Snubber is one of the most important parts in hydrogen compressing system. It has installed reciprocating hydrogen compressor. One of these components is snubber which has function to reduce pulsation waveform and to remove the impurities in the hydrogen gas. A snubber has an inclined plate as a buffer, which is installed inside snubber. When the pressure loss and the pulsation of pressure within a snubber is minimized, the snubber could get more applicability. Therefore, a study to find an optimum geometric size on a several snubbers which have different buffer width, has been conducted using a numerical analysis.

  • PDF

Experimental research on 2 stage GM-type pulse tube refrigerator for cryopump

  • Park, Seong-Je;Ko, Jun-Seok;Hong, Yong-Ju;Kim, Hyo-Bong;Yeom, Han-Kil;Koh, Deuk-Yong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.29-33
    • /
    • 2010
  • The experimental results of the 2 stage Gifford-McMahon(GM) type pulse tube refrigerator (PTR) or cryopump are presented in this paper. The objectives of his study are to develop design technology of the integral type 2 stage PTR which rotary valve is directly connected to he hot end of the regenerator and acquire its improved performance. Design of the 2 stage PTR is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program for the design of pulse tube refrigerators. The fabricated PTR has U-type configuration and incorporates orifice valve, double-inlet valve and reservoir as phase control mechanism. Rotary valve is used to make pulsating pressure and is directly connected to inlet of $1^{st}$ stage regenerator. From experiments, cooling performance map and pressure waveform at each point were measured for different operating frequencies. Experimental results show the best cooling performance with 2 Hz operation in spite of small pressure amplitude. The lowest temperatures of the 2 stage PTR were 16.9 K at the second stage and 58.0 K at the first stage. The cooling capacities achieved were 14.4 W at 79 K, the first stage and 3.6 W at 29 K, the second stage.

Seismic performance evaluation of agricultural reservoir embankment based on overtopping prevention structures installation

  • Bo Ra Yun;Jung Hyun Ryu;Ji Sang Han;Dal Won Lee
    • 농업과학연구
    • /
    • 제50권3호
    • /
    • pp.469-484
    • /
    • 2023
  • In this study, three types of structures-stepped gabion retaining walls, vertical gabion retaining walls, and parapets-were installed on the dam floor crest to prevent the overflow of deteriorative homogeneous reservoirs. The acceleration response, displacement behavior, and pore water pressure ratio behavior were compared and evaluated using shaking-table model tests. The experimental conditions were set to 0.154 g in consideration of the domestic standard and the seismic acceleration range according to the magnitude of the earthquake, and the input waveform was applied with Pohang, Gongen, and artificial earthquake waves. The acceleration response according to the design ground acceleration increased as the height of the embankment increased, and the observed value were larger in the range of 1.1 to 2.1 times the input acceleration for all structures. The horizontal and vertical displacements exhibited maximum values on the upstream slope, and the embankment was evaluated as stable and included within the allowable range for all waveforms. The settlement ratio considering the similarity law exhibited the least change in the case of the parapet structure. The amplification ratio was 1.1 to 1.5 times in all structures, with the largest observed in the dam crest. The maximum excess pore water pressure ratio was in the range of 0.010 - 0.021, and the liquefaction evaluation standard was within 1.0, which was considered very stable.

PPG 및 ECG 센서를 이용한 혈압추정 기법 개발 (Development of Blood Pressure Estimation Methods Using The PPG and ECG Sensors)

  • 박현문;이정철;황태호
    • 한국전자통신학회논문지
    • /
    • 제14권6호
    • /
    • pp.1257-1264
    • /
    • 2019
  • 기존의 Cuff 기반의 혈압(Blood Pressure)측정 방법은 연속적인 실시간 혈압측정에는 한계를 갖는다. 이러한 이유로 ECG와 PPG 센서 신호를 상호융합한 다양한 혈압추정이 이루어졌다. 그러나 PPG 중심에 측정기법은 AC 노이즈, 작은 맥동, 비박동 등의 많은 문제를 지니고 있다. 본 논문은 ECG와 PPG 관계에 발생하는 맥파전달시간(PTT)과 맥파속도(PWV)를 이용하여 혈압을 추론기법이다. 신호 피크를 이용하는 HRF(Height Ratio Features)에 비해, 본 제안방식은 ECG, PPG의 최고점 혹은 최저점을 사용한 시차를 이용해 추정하기 때문에 PPG 센싱 시그널의 오류에도 안정적인 추출이 가능한 장점이 있다. 본 논문에서 제안 방법을 이용하여 25만 회의 혈압측정의 결과 ±28.5%의 정확도를 갖는 혈압 추정기법을 제시할 수 있었다.

5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석 (Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

요골동맥 직경 변화에 따른 맥파 측정 시스템 개발 (Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation)

  • 이전;우영재;전영주;이유정;김종열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.