• 제목/요약/키워드: pressure transducer

검색결과 329건 처리시간 0.026초

압력 센서 개발 및 내연기관의 피스톤 링 사이 가스압력 측정 (Development of Pressure Transducer and Measurement of Inter-Ring Gas Pressure in Internal Combustion Engine)

  • 윤정의;이귀영
    • 한국자동차공학회논문집
    • /
    • 제4권1호
    • /
    • pp.75-85
    • /
    • 1996
  • The gas pressure acting on the rings in internal combustion engine influences the friction, wear and HC emission. In order to understand their characteristics, it is necessary to measure the interring gas pressure during engine operations. In this study, miniature type pressure transducer was developed to measure inter-ring gas pressure. And measurements of cylinder and inter-ring gas pressure were made on a gasoline engine running at full and part load conditions. Finally the characteristics of inter-ring gas pressure variation during engine operation were obtained form analysis of measured date.

  • PDF

설계변수들의 상호효과를 고려한 Flextensional 트랜스듀서의 최적설계 (Optimal Design of a Flextensional Transducer Considering All the Cross-coupled Effects of the Design Variables)

  • 강국진;노용래
    • 한국소음진동공학회논문집
    • /
    • 제13권5호
    • /
    • pp.364-374
    • /
    • 2003
  • The performance of an acoustic transducer is determined by the effects of many design variables. and mostly the influences of these design variables are not linearly independent of each other To achieve the optimal performance of an acoustic transducer, we must consider the cross-coupled effects of the design variables. In this study with the FEM. we analyzed the variation of the resonance frequency and sound pressure of a flextensional transducer in relation to Its design variables. Through statistical multiple regression analysis of the results, we derived functional forms of the resonance frequency and sound pressure in terms of the design variables, and with which we determined the optimal structure of the transducer by means of a constrained optimization technique, SQP-PD. The proposed method can reflect all the cross-coupled effects of multiple design variables, and can be utilized to the design of general acoustic transducers.

결합형 유한요소-경계요소 기법을 사용한 심해저용 압전형 유연성 쏘나 변환기의 시뮬레이션 (Simulation of a piezoelectric flextentional deep-water sonar transducer using a coupled FE-BEM)

  • 장순석;이제형;안흥구;최현호
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1999년도 학술발표대회 논문집 제18권 1호
    • /
    • pp.218-223
    • /
    • 1999
  • A piezoelectric flextentional deep-water sonar transducer has been simulated using a coupled FE-BEM. The dynamics of the sonar transducer is modelled in three dimensions and is analyzed with extern리 electrical excitation conditions as well as external acoustic pressure loading conditions. Different results are available such as steady-state frequency response for RX and TX, displacement modes, directivity patterns, back-scattering patterns, resonant frequencies, bandwidths, quality factors, transmitting voltage (TV) responses, input receiving sensitivity (RS) responses. White the present barrel-stave typed sonar transducer of the piezoelectric material is being simulated, the external surface of the transducer is modified in order to allow the same water pressure to be applied to the inner and the outer surfaces of the transducer. With this modification for deep-water application, the resonance frequency of the modified flextentional sonar transducer becomes much lower than that of the unmodified flextentional sonar transducer. The results of the present sonar transducer modelling are also compared with those of a commercial package such as ATILA.

  • PDF

비미분형 맥동검출변환기 개발 (Developed of non-differential pulse detection)

  • 김현규;한상휘;이용동;박영배;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.573-576
    • /
    • 1998
  • In this paper, we devised pulse detection transducer that has non-differential characteristics for pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever. Therefore the pressure pulse signal can obtain by the developed transducer. As the results of experiment, the developed transducer has a good linearity at pressure to voltage conversion and acan detect non-differential pulse signal from chongu artery.

  • PDF

선미선저(船尾船底)에 미치는 추진기(推進器) 유기압력(誘起壓力) -선체표면(船體表面)에 붙인 압력변환기(壓力變換器)로 계측(計測)되는 압력(壓力)으로부터의 한 분리방법(分離方法)- (Propeller Induced Pressure on Bottom Surface of Stern -A Method of Seperation from the Measured Pressure with Pressure Transducer attached on Hull Surface.)

  • 조규종
    • 대한조선학회지
    • /
    • 제7권1호
    • /
    • pp.1-12
    • /
    • 1970
  • The propeller induced pressure fluctuation around a ship's stern is one of the interesting problems from viewpoints of the noise and vibration. Most of the experimental works on the subject employ pressure transducer attached on hull surface near the propeller. In the technique, the measured pressure includes the hydrodynamic pressure transducer attached, if they exit. Hence, the separation of the additional pressure due to vibration from the measured pressure is essential for the determination of true values of the propeller induced pressure. In this paper, to contribute to the separation method, the author investigated the additional hydrodynamic pressure as below, based on the numerical calculation. (1) Hydrodynamic pressure on the body surface of two dimensional cylinders of some mathematical sections such as ellipse, rectangle, Lewis form of hypotrocoidal charactor and curvilinear-element section with chines oscillating vertically at high frequency in a free surface. (2) Hydrodynamic pressure on the surface of the shell plate in local vibration in an ideal fluid.

  • PDF

압전식 압력센서에서 발생하는 열충격 효과 정량화 (Quantification of Thermal Shock in a Piezoelectric Pressure Transducer)

  • 이석환;최욱;배충식
    • 한국자동차공학회논문집
    • /
    • 제13권5호
    • /
    • pp.96-103
    • /
    • 2005
  • One of the major problems limiting the accuracy of piezoelectric transducers fur cylinder pressure measurements in an internal combustion (IC) engine is the thermal shock. Thermal shock is generated from the temperature variation during the cycle. This temperature variation results in contraction and expansion of the diaphragm and consequently changes the force acting on the quartz in the pressure transducer An empirical equation for compensation of the thermal shock error was derived from consideration of the diaphragm thermal deformation and actual pressure data. The result indicate that the thermal shock equation provides reliable correction based on known surface temperature swing.

모터링 압력측정을 통한 상사점 결정방법에 관한 연구 (A study on TDC crank angle determination by motoring pressure measurement)

  • 한정옥;이영주;김승수
    • 오토저널
    • /
    • 제10권6호
    • /
    • pp.39-47
    • /
    • 1988
  • A disk photo sensor system was constructed and installed on engine for the crank angle measurement. Statically measured TDC crank angle data were compared with those obtained from engine motoring. Two groups of cylinder pressure data were compared each other, one measured by pressure transducer mounted flush on the combustion chamber and the other obtained with the help of spark plug type adaptor. A simple analysis on the gas flow in the spark plug type pressure transducer displayed reasonably good agreement with those from engine motoring tests. In various firing tests, the IMERs obtained from the spark plug type pressure transducer turned out to be higher than those from the flush mounted one at low engine speed while those two were nearly the same at high engine speed. As the engine load decreased the relative difference in IMEP measurement between the two types tended to be enlarged.

  • PDF

총안 맥진을 위한 맥동검출기 개발에 관한 연구( I ) (A Study on the Radial Pulse Detection System for the Total Macjin( I ))

  • 김규상;양승렬;한순천;박영배;김정국;허웅
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 하계종합학술대회 논문집
    • /
    • pp.551-554
    • /
    • 1999
  • In this paper, we developed a radial pulse transducer that has strain-gauge cantilever type load cell for total pulse detection on chongu arterial. The transducer consist of load cell and driving electronic circuits. Load cell consist of cantilever and two metal film strain gauge. The Pressure signal from chongu artery is delivered to load cell using artery rider that attached to cantilever Therefore the pressure signal convert to voltage signals by the developed transducer As the results of experiment, the developed transducer has very good linearity at pressure to voltage conversion. The total pulse detection transducer can detected three kinds of chongu artery pulse with conveniently.

  • PDF

Development of a High Power Ultrasonic Transducer for Steel Pickling Process

  • Han, Chang-Soo;Kim, Jeong-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.65.3-65
    • /
    • 2001
  • In order to apply for pickling line in cold rolling process, a high power magnetostrictive ultrasonic transducer was developed. The transducer is expected to overcome the shortcomings of conventional high power ultrasonic transducers. The transducer consists of Fe-Co-V alloy sheets for the magnetostrictive material, an ultrasonic horn made of Hastelloy to withstand acid solution, and electric driving circuit. In the development, the transducer was designed with the theoretical and numerical methods such as finite element method, and was characterized with experimental water tanks. The developed transducers turned out to be able to generate the sound pressure up to 20,000 Pa, and to be suitable for application ...

  • PDF

대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석 (Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model)

  • 최호선
    • 정보학연구
    • /
    • 제8권1호
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF