• Title/Summary/Keyword: pressure tap

Search Result 74, Processing Time 0.018 seconds

Size measurement of electrosprayed droplets using shadowgraph visualization method (Shadowgraph 가시화 기법을 활용한 정전분무액적의 크기 측정)

  • Oh, Min-Jeong;Kim, Sung-Hyun;Lee, Myong-Hwa
    • Particle and aerosol research
    • /
    • v.13 no.4
    • /
    • pp.151-158
    • /
    • 2017
  • Electrostatic precipitator is widely used to remove particulate matters in indoor air and industrial flue gas due to low pressure drop and high collection efficiency. However, it has a low collection efficiency for the submicrometer sized particles. Electrospraying is a potential method to increase the particle charging efficiency, which results in increased collection efficiency. Although particle charging efficiency is highly dependent upon droplet size, the effective measuring method of the droplets is still uncertain. Tap water was electrosprayed in this study, and the images of electrosprayed droplets were taken with a high speed camera coupled with several visualization methods in order to measure the droplets size. The droplet size distribution was determined by an image processing with an image-J program. As a result, a droplet measured by a laser visualization, had a half size of that by a Xenon light visualization. In addition, the experimentally measured droplet sizes were a good agreement with the predicted values suggested by $Fern{\acute{a}}ndez$ de la Mora and Loscertales(1994).

Analysis of Hydrodynamic Similarity in Three-Phase Fluidized Bed Processes (삼상유동층 공정에서 수력학적 Similarity 해석)

  • Lim, Ho;Lim, Hyun-Oh;Jin, Hae-Ryoung;Lim, Dae-Ho;Kang, Yong
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.790-797
    • /
    • 2011
  • Hydrodynamic similarity was analyzed by employing scaling factor in three phase fluidized beds. The scaling factor was defined based on the holdups of gas, liquid and solid particles and effectivity volumetric flux of fluids between the two kinds of fluidized beds with different column diameter. The column diameter of one was 0.102 m and that of the other was 0.152 m. Filtered compressed air, tap water and glass bead of which density was 2,500 kg/$m^3$ were used as gas, liquid and solid phases, respectively. The individual phase holdups in three phase fluidized beds were determined by means of static pressure drop method. Effects of gas and liquid velocities and particle size on the scaling factors based on the holdups of each phase and effective volumetric flux of fluids were examined. The deviation of gas holdup between the two kinds of three phase fluidized beds decreased with increasing gas or liquid velocity but increased with increasing fluidized particle size. The deviation of liquid holdup between the two fluidized beds decreased with increasing gas or liquid velocity or size of fluidized solid particles. The deviation of solid holdup between the two fluidized beds increased with increasing gas velocity or particle size, however, decreased with increasing liquid velocity. The deviation of effective volumetric flux of fluids between the two fluidized beds decreased with increasing gas velocity or particle size, but increased with increasing liquid velocity. The scaling factor, which was defined in this study, could be effectively used to analyze the hydrodynamic similarity in three phase fluidized processes.

Size Verification of Small and Large Bubbles in a Bubble Column (기포탑에서 작은기포와 큰기포의 크기 구별)

  • Seo, Myung Jae;Jin, Hae-Ryong;Lim, Dae Ho;Lim, Ho;Kang, Yong;Jun, Ki-Won
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.304-309
    • /
    • 2012
  • Size verification of small and large bubbles in a bubble column was investigated by employing the dynamic gas disengagement (DGD) method and dual electrical resistivity probe (DRP) method, simultancously. The holdups of large and small bubbles in the bubble column in a given operating condition were obtained by means of the DGD method by measuring the pressure drop variation in the column with a variation of time after stopping the gas input into the column. The size and frequency of bubbles were measured by the DRP method in the same operating condition, from which the bubble holdup of each range of size was obtained. The verification of size in determining the large or small bubbles was decided by comparing the holdups of large or small bubbles measured by the DGD method with that measured by the DRP method. Filtered compressed air and tap water were used as a gas and a continuous liquid medium. The diameter and height of the bubble column were 0.102 m and 1.5 m, respectively. The demarcation size between the large and the small bubbles in the bubble column was 4.0~5.0 mm; the demarcation size was about 5.0 mm when the gas velocity was in the relatively low range, but about 4.0 mm when the gas velocity was in the relatively high range, within this experimental conditions.

Interaction between Renin-Angiotensin and Endothelium-Derived Nitric Oxide Systems in Two-Kidney, One Clip Hypertensive Rats

  • Ahn, Hyun-Tack;Nah, Kook-Joo;Lee, Jong-Un
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.33-41
    • /
    • 1996
  • The present study was aimed to investigate the role of endothelium-derived nitric oxide (NO) in the control of renin release and to examine if NO is implicated in the development of two-kidney, one clip (2K1C) hypertension. Male Sprague-Dawley rats $(150{\sim}200\; g)$ were constricted at the left renal artery. They were then supplemented with $N^{G}-nitro-L-arginine\;methyl\;ester\;(L-NAME,\; 5mg/100\;mL)$ or with L-arginine hydrochloride (400 mg/100 mL) in the drinking water. The control group was supplied with normal tap water. The sham-clipped rats were operated as in 2K1C rats except for that no clip was made. The kidneys were taken to examine in vitro release of renin at days 7 and 14 following clipping the renal artery. Northern blot analysis was also done to assess the expression of renin gene in the kidney. In sham-clipped rats, L-NAME caused a sustained increase of the blood pressure, whereas L-arginine was without effect. Neither L-NAME nor L-arginine-supplementation significantly affected the development of hypertension in 2K1C rats. Plasma renin concentration (PRC) measured on day 28 did not significantly differ among the L-NAME, L-arginine and control groups either in 2K1C or in sham-clipped rats. Renin contents (RRC) in the clipped kidney were increased, while those in the contralateral kidney were decreased. The release of renin in vitro from cortical slices was also enhanced in the clipped kidney, whereas it was attenuated in the contralateral. Comparing the RRC and in vitro release, the latter was more rapidly decreased than the former in the contralateral kidney. The renin mRNA levels in the contralateral kidney were almost at their nadir at days 7 and 14 in 2K1C rats. It is suggested that NO does not affect the development of 2K1C hypertension in which the renin-angiotensin system has been activated. The data also confirm that RRC and renin gene expression are increased in the clipped kidney and suppressed in the contralateral kidney in 2K1C rats.

  • PDF