• 제목/요약/키워드: pressure reduction

검색결과 2,658건 처리시간 0.028초

수중 음향재료의 반향음 감소성능 연구 (A Study on the Echo Reduction Performance of Underwater Acoustic Material)

  • 서영수;함일배;정우진
    • 한국소음진동공학회논문집
    • /
    • 제24권11호
    • /
    • pp.868-875
    • /
    • 2014
  • The requirement of acoustic material which is used in underwater environment more increases. The material is used to reduce acoustic signature and radiate noise for underwater vehicle. Underwater acoustic material was made by viscoelastic material such as rubber and polyurethane etc. The mechanical and acoustic characteristics of these material change with hydrostatic pressure. In order to improve an acoustic performance according to hydrostatic pressure, several kinds of scatterers were added to viscoelastic material. In this paper, acoustic modelling and analysis techniques of underwater acoustic material with hydrostatic pressure were introduced and proposed. The specimens for pulse tube test were made and echo reductions were calculated and measured with hydrostatic pressure. Also the characteristics of echo reduction of the specimens with hydrostatic pressure were obtained and discussed.

심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로- (Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment-)

  • 정연희;양영모
    • 한국의류학회지
    • /
    • 제36권11호
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.

임계압력 근처에서의 환형관 채널에 대한 열전달 특성 연구 (Heat Transfer Characteristics of an Annulus Channel Cooled with R-134a Fluid near the Critical Pressure)

  • 홍성덕;천세영;김세윤;백원필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2094-2099
    • /
    • 2004
  • An experimental study on heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with the increase of the system pressure For a fixed inlet mass flux and subcooling, the CHF falls sharply at about 3.8 MPa and shows a trend toward converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall because the CHF occurred at remarkably low power levels. In the pressure reduction transient experiments, as soon as the pressure passed through the critical pressure, the wall temperatures rise rapidly up to a very high value due to the occurrence of the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, then tends to decrease gradually.

  • PDF

金屬錯이온의 폴라로그래피的 파라미터에 미치는 壓力의 影響 (Effect of High Pressure on Polarographic Parameters of Metal Complex Ion)

  • 이흥락;배준웅;윤종훈
    • 대한화학회지
    • /
    • 제31권5호
    • /
    • pp.444-451
    • /
    • 1987
  • 에틸렌디아민, 프로필렌디아민 및 디에틸렌트리아민의 구리(II), 카드뮴(II) 및 아연(II)착이온의 桓元에 대하여 압력에 따른 폴라로그래피적 파라미터의 依存性을 조사하였다. 水銀滴下電極, 고인수은전극 및 나선형 백금선을 각각 作業電極, 基準電極 및 補助電極으로 사용하였다. 압력이 1기압에서 1,500기압으로 증가함에 따라 금속착이온의 還元半波電位는 陰電位 쪽으로 이동하였으며, 擴散電流는 상당히 커졌다. 이러한 현상은 전해질용액의 물리적 성질 곧 密度, 粘性度, 誘電常數, 電氣傳導度 등이 압력이 증가함에 따라 커지기 때문이다. 압력을 증가시키면 log plot의 기울기 값이 커지므로 환원반응의 可逆性은 나빠지고 있다. 25$^{\circ}$C ~ 35$^{\circ}$C의 온도범위에서 측정한 확산전류의 溫度係數가 압력을 증가시켜도 2%정도이므로 高壓下에서 폴라로그래피적 환원반응은 擴散支配的이다. 또 실험압력 범위내에서 금속착이온의 확산전류와 농도 사이에는 線形關係가 성립하였다.

  • PDF

수치해석에 의한 지중 구속압과 말뚝-지반 경계면 강도감소계수 관계 분석 (A Study on the Correlation Evaluation of Confining Pressure and Pile-Soil Interface Strength Reduction Factor Using Numerical Analysis)

  • 이태겸;한중근;홍기권;유승경
    • 한국지반신소재학회논문집
    • /
    • 제23권1호
    • /
    • pp.9-16
    • /
    • 2024
  • 본 연구에서는 지중 구속압과 말뚝-지반 경계면 전단 특성의 관계를 평가하기 위하여 기존의 실험결과와 강도감소계수가 적용된 해석 결과를 비교하였다. 유한요소해석에서 말뚝-지반 경계면의 전단거동 모사는 강도감소계수를 적용하였다. 해석 결과, 세립분 함유율이 증가할수록 구속압의 영향이 낮아지면서 최대 인발저항력은 감소하였다. 이 해석결과의 경향은 기존 실험 결과와 유사한 것으로서, 경계면 강도감소계수가 적용된 유한요소해석 모델은 적절하게 모사된 것으로 평가되었다. 경계면 강도감소계수의 변화를 분석한 결과, 구속압 50kPa의 경우에는 세립분 함유율이 증가할수록 경계면 강도감소계수의 증가가 확연하게 나타난 반면에, 구속압이 100kPa 및 150kPa의 경우에는 그 증가폭이 낮은 것을 알 수 있었다. 따라서 말뚝-지반 경계면의 전단 거동을 평가하기 위한 유한요소해석은 구속압과 세립분 함유율이 고려되어야 한다.

엡셋팅에 의한 냉간 압접의 결합 기구와 결합강도 (The bonding mechanism and bond strength of cold pressure welding)

  • 한인철;김재도
    • Journal of Welding and Joining
    • /
    • 제8권3호
    • /
    • pp.31-38
    • /
    • 1990
  • The bonding mechanism and bond strength were investigated for the cold pressure welding of Al to Al, Cu to Cu and Al to Cu by upsetting. A phenomenon of bonding betweenthe metallic components has been observed by a scanning electron microscope and metallurgical microscope. A modified equation for bond strength with respect to the reduction of height shows reasonably a good agreement with the experimental data. When the values of the hardening factor and threshold deformation for the given materials could be determined, the theoretical bond strength can be calculated.

  • PDF

업셋팅 을 이용한 냉간압접 에 대한 연구 (Study on the cold pressure welding by upsetting)

  • 안기원;김재도
    • Journal of Welding and Joining
    • /
    • 제3권2호
    • /
    • pp.27-34
    • /
    • 1985
  • The mechanical properties and bonding mechanism of aluminum, copper and mild steel have been determined in cold pressure welding. The brittle cover layer to be established by scratch-brushing plays an important role in bond strength and has an influence on the threshold of deformation. The cold pressure welding was achieved at 54% of height reduction in A1-A1, 75% in Cu-Cu, 56% in Al-Cu, and 74% in Cu-steel. The height reduction at which the bond strength of weld interface was the same as the tensile strength of base metal should be over 76% in Al-Al, 82% in Cu-Cu, and 78% in Al-Cu.

  • PDF

경락마사지가 근막동통 증후군의 동통과 자각증상 감소에 미치는 효과 (The Effect of Meridian Massage on the Reduction of Pain and Subjective Symptoms of Myofascial Pain Syndrome)

  • 성경숙;정향미
    • 재활간호학회지
    • /
    • 제6권2호
    • /
    • pp.248-256
    • /
    • 2003
  • Purpose: This research was for checking the effect of meridian massage on the reduction of pain and subjective symptoms of myofascial pain syndrome. Method: The method of the research was interruptive time series design. The research objects are 25 hospital workers with myofascial pain syndrome at B hospital in Busan from July 22, 2002 to August 18, 2002. SPSS Win 10.0 was used for data analysis, paired t-test and repeated measures ANOVA for hypothesis test. Result: The recipients of meridian massage felt less pain than before(F=12.587, p=.000). The recipients of meridian massage felt less often than before (F=6.705, p=.001). The recipients of meridian massage got lower score on subjective symptoms of myofascial pain than before(F=12.857, p=.000). The recipients of meridian massage had lower blood pressure than before(systolic blood pressure; t=4.697, p=.000, diastolic blood pressure; t=3.426, p=.002). The recipients of meridian massage did not get the lower number of pulse than before(t=0.33, p=.744). Conclusion: The above results show that meridian massage is effective on the reduction of pain and subjective symptoms of myofascial pain syndrome and makes stable the blood pressure. Therefore meridian massage can be apply as the effective intervention for the reduction of pain and subjective symptoms of myofascial pain syndrome.

  • PDF

풍동시험과 CFD를 통한 방풍망의 풍속저감 효과 (Effects of an Anti-wind Net on Wind Velocity Reduction by a Wind Tunnel Test and CFD)

  • 염성현;강승희;김승희;이상봉;김민영
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.355-360
    • /
    • 2011
  • This study was carried out to analyze the installation effect of an anti-wind net on reducing wind velocity which was used to protect orchards as well as single-span plastichouses. The pressure drop through three types of anti-wind net was measured in a subsonic wind tunnel. The wind reduction through the anti-wind facility for several sets in respect to three types of the net and heights of the facility ranging from 3 to 11 m was analyzed by using computational fluid dynamics (CFD). The measured data showed that the pressure drop increased as an equation of the second degree of the inlet wind velocity. Numerical computations exhibited that the effect of wind reduction definitely augmented as the net size became smaller and increased with the height of the facility being heightened to some extent. For the typical and widely used anti-wind facility with a height of 5 m and a net size of 4mm, the amount of wind reduction came up to 5.1 m/s for the inlet wind velocity of 20 m/s, and also 7.6 and 10.1 m/s for the inlet wind velocities of 30 and 40 m/s, respectively. In case for the orchard's longitudinal length to be within about 200 m, the appropriately effective height of the facility was predicted to be 5 m. Finally, the negative total pressure on the top face of the single-span plastichouse certainly reduced for all the cases with the anti-wind facility being installed. In particular, the reduction of the negative total pressure was more considerable as the inlet wind velocity increased.

중대형 굴삭기 유압시스템의 압력 맥동 저감 연구 (A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-large Excavator)

  • 김영현;주원호
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.18-23
    • /
    • 2011
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.