• Title/Summary/Keyword: pressure ratio

Search Result 5,715, Processing Time 0.036 seconds

Effect of slope with overburden layer on the bearing behavior of large-diameter rock-socketed piles

  • Xing, Haofeng;Zhang, Hao;Liu, Liangliang;Luo, Yong
    • Geomechanics and Engineering
    • /
    • v.24 no.4
    • /
    • pp.389-397
    • /
    • 2021
  • Pile foundation is a typical form of bridge foundation and viaduct, and large-diameter rock-socketed piles are typically adopted in bridges with long span or high piers. To investigate the effect of a mountain slope with a deep overburden layer on the bearing characteristics of large-diameter rock-socketed piles, four centrifuge model tests of single piles on different slopes (0°, 15°, 30° and 45°) were carried out to investigate the effect of slope on the bearing characteristics of piles. In addition, three pile group tests with different slope (0°, 30° and 45°) were also performed to explore the effect of slope on the bearing characteristics of the pile group. The results of the single pile tests indicate that the slope with a deep overburden layer not only accelerates the drag force of the pile with the increasing slope, but also causes the bending moment to move down owing to the increase in the unsymmetrical pressure around the pile. As the slope increases from 0° to 45°, the drag force of the pile is significantly enlarged and the axial force of the pile reduces to beyond 12%. The position of the maximum bending moment of the pile shifts downward, while the magnitude becomes larger. Meanwhile, the slope results in the reduction in the shaft resistance of the pile, and the maximum value at the front side of the pile is 3.98% less than at its rear side at a 45° slope. The load-sharing ratio of the tip resistance of the pile is increased from 5.49% to 12.02%. The results of the pile group tests show that the increase in the slope enhances the uneven distribution of the pile top reaction and yields a larger bending moment and different settlements on the pile cap, which might cause safety issues to bridge structures.

Risk Factors and Clinical Outcomes of Brain Reperfusion Injury after Mechanical Thrombectomy for Ischemic Stroke (기계적 혈전제거술을 시행한 허혈성 뇌졸중 환자의 뇌재관류 손상 위험요인과 임상결과)

  • Moon, Ji Hyun;Choi, Hye-Ran
    • Journal of Korean Biological Nursing Science
    • /
    • v.23 no.3
    • /
    • pp.217-226
    • /
    • 2021
  • Purpose: The aim of this study was to investigate the risk factors for brain reperfusion injury in ischemic stroke patients and to analyze the clinical outcomes. Methods: A retrospective study was conducted in 168 patients who underwent mechanical thrombectomy. The data were analyzed using descriptive statistics, t-test, Mann-Whitney U test, Chi-Square test, Fisher's exact test, and logistic regression with IBM SPSS/WIN 24.0. Results: Brain reperfusion injury occurred in 67 patients (39.9%) with a low favored outcome (𝛘2=6.01, p=.014). On multivariable analysis, blood urea nitrogen (Odds ratio [OR]=1.14, 95% Confidence interval [CI]=1.06-1.23), aphasia (OR=6.16, CI=1.62-23.40), anosognosia (OR=4.84, CI=1.13-20.79), presence of both aphasia and anosognosia (OR=7.33, CI=1.20-44.60), and time required to achieve targeted blood pressure (OR=1.00, CI=1.00-1.00) were identified as risk factors for brain reperfusion injury. A statistically significant difference was detected in clinical outcomes, including hemorrhagic transformation (𝛘2=6.32, p=.012), intensive care unit length of stay (Z=-2.08, p=.038), National Institute of Health Stroke scale score at discharge (Z=-3.14, p=.002), and modified Rankin Scale score at discharge (Z=-2.93, p=.003). Conclusion: This study identified the risk factors and presented the clinical outcomes of brain reperfusion injury. It is necessary to consider these risk factors for evaluating the patients and to establish nursing interventions and strategies.

Cardiac Dysfunction Is Not Associated with Increased Reintubation Rate in Patients Treated with Post-extubation High-Flow Nasal Cannula

  • Sim, Jae Kyeom;Choi, Juwhan;Oh, Jee Youn;Min, Kyung Hoon;Hur, Gyu Young;Lee, Sung Yong;Shim, Jae Jeong;Lee, Young Seok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.4
    • /
    • pp.332-340
    • /
    • 2022
  • Background: Cardiac dysfunction patients have long been considered at high risk of reintubation. However, it is based on past studies in which only conventional oxygen therapy was applied after extubation. We investigated association between cardiac dysfunction and reintubation rate in situation where high-flow nasal cannula (HFNC) was widely used during post-extubation period. Methods: We conducted a retrospective observational cohort study of patients treated with HFNC after planned extubation in medical intensive care unit of single tertiary center. Patients were divided into normal function group (ejection fraction [EF] ≥45%) and cardiac dysfunction group (EF <45%). The primary outcome was reintubation rate within 72 hours following extubation. Results: Of 270 patients, 35 (13%) had cardiac dysfunction. Baseline characteristics were similar in both groups. There were no differences in the changes in vital signs between the two groups during the first 12 hours after extubation except diastolic blood pressure. The reintubation rates were 20% and 17% for cardiac dysfunction group and normal function group, respectively (p=0.637). In a multivariate Cox regression analysis, cardiac dysfunction was not associated with an increased risk of reintubation within 72 hours following extubation (hazard ratio, 1.56; p=0.292). Conclusion: Cardiac dysfunction was not associated with increased reintubation rate within 72 hours when HFNC is immediately applied after planned extubation.

Design and heat transfer optimization of a 1 kW free-piston stirling engine for space reactor power system

  • Dai, Zhiwen;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2184-2194
    • /
    • 2021
  • The Free-Piston Stirling engine (FPSE) is of interest for many research in aerospace due to its advantages of long operating life, higher efficiency, and zero maintenance. In this study, a 1-kW FPSE was proposed by analyzing the requirements of Space Reactor Power Systems (SRPS), of which performance was evaluated by developing a code through the Simple Analysis Method. The results of SAM showed that the critical parameters of FPSE could satisfy the designed requirements. The heater of the FPSE was designed with the copper rectangular fins to enhance heat transfer, and the parametric study of the heater was performed with Computational Fluid Dynamics (CFD) software STAR-CCM+. The Performance Evaluation Criteria (PEC) was used to evaluate the heat transfer enhancement of the fins in the heater. The numerical results of the CFD program showed that pressure drop and Nusselt number ratio had a linear growth with the height of fins, and PEC number decreased as the height of fins increased, and the optimum height of the fin was set as 4 mm according to the minimum heat exchange surface area. This paper can provide theoretical supports for the design and numerical analysis of an FPSE for SRPSs.

Fabrication of surface-enhanced Raman scattering substrate using black silicon layer manufactured through reactive ion etching (RIE 공정으로 제조된 블랙 실리콘(Black Silicon) 층을 사용한 표면 증강 라만 산란 기판 제작)

  • Kim, Hyeong Ju;Kim, Bonghwan;Lee, Dongin;Lee, Bong-Hee;Cho, Chanseob
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.4
    • /
    • pp.267-272
    • /
    • 2021
  • In this study, Ag was deposited to investigate its applicability as a surface-enhanced Raman scattering substrate after forming a grass-type black silicon structure through maskless reactive ion etching. Grass-structured black silicon with heights of 2 - 7 ㎛ was formed at radio-frequency (RF) power of 150 - 170 W. The process pressure was 250 mTorr, the O2/SF6 gas ratio was 15/37.5, and the processing time was 10 - 20 min. When the processing time was increased by more than 20 min, the self-masking of SixOyFz did not occur, and the black silicon structure was therefore not formed. Raman response characteristics were measured based on the Ag thickness deposited on a black silicon substrate. As the Ag thickness increased, the characteristic peak intensity increased. When the Ag thickness deposited on the black silicon substrate increased from 40 to 80 nm, the Raman response intensity at a Raman wavelength of 1507 / cm increased from 8.2 × 103 to 25 × 103 cps. When the Ag thickness was 150 nm, the increase declined to 30 × 103 cps and showed a saturation tendency. When the RF power increased from 150 to 170 W, the response intensity at a 1507/cm Raman wavelength slightly increased from 30 × 103 to 33 × 103 cps. However, when the RF power was 200 W, the Raman response intensity decreased significantly to 6.2 × 103 cps.

Analysis of Si Etch Uniformity of Very High Frequency Driven - Capacitively Coupled Ar/SF6 Plasmas (VHF-CCP 설비에서 Ar/SF6 플라즈마 분포가 Si 식각 균일도에 미치는 영향 분석)

  • Lim, Seongjae;Lee, Ingyu;Lee, Haneul;Son, Sung Hyun;Kim, Gon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.4
    • /
    • pp.72-77
    • /
    • 2021
  • The radial distribution of etch rate was analyzed using the ion energy flux model in VHF-CCP. In order to exclude the effects of polymer passivation and F radical depletion on the etching. The experiment was performed in Ar/SF6 plasma with an SF6 molar ratio of 80% of operating pressure 10 and 20 mTorr. The radial distribution of Ar/SF6 plasma was diagnosed with RF compensated Langmuir Probe(cLP) and Retarding Field Energy Analyzer(RFEA). The radial distribution of ion energy flux was calculated with Bohm current times the sheath voltage which is determined by the potential difference between the plasma space potential (measured by cLP) and the surface floating potential (by RFEA). To analyze the etch rate uniformity, Si coupon samples were etched under the same condition. The ion energy flux and the etch rate show a close correlation of more than 0.94 of R2 value. It means that the etch rate distribution is explained by the ion energy flux.

Sevoflurane with opioid or dexmedetomidine infusions in dogs undergoing intracranial surgery: a retrospective observational study

  • Marquez-Grados, Felipe;Vettorato, Enzo;Corletto, Federico
    • Journal of Veterinary Science
    • /
    • v.21 no.1
    • /
    • pp.8.1-8.11
    • /
    • 2020
  • This study reports the clinical use of two sevoflurane-based anesthetic techniques in dogs undergoing craniectomy. Twenty-one animals undergoing elective rostrotentorial or transfrontal craniectomy for brain tumor excision, anesthetized with sevoflurane, were enrolled in this retrospective, observational study. Anesthetic records were allocated to two groups: Sevo-Op (sevoflurane and short acting opioid infusion): 8 dogs and Sevo-Dex (sevoflurane and dexmedetomidine infusion): 13 dogs. Average mean arterial pressure (MAP), heart rate, end-tidal carbon dioxide, end-tidal sevoflurane and intraoperative infusion rates during surgery were calculated. Presence of intra-operative and post-operative bradycardia, tachycardia, hypotension, hypertension, hypothermia, hyperthermia was recorded. Time to endotracheal extubation, intraoperative occurrence of atrioventricular block, postoperative presence of agitation, seizures, use of labetalol and dexmedetomidine infusion were also recorded. Data from the two groups were compared with Fisher's exact test and unpaired t tests with Welch's correction. Odds ratio (OR) and 95% confidence interval (CI) were calculated for categorical variables. Intra-operatively, MAP was lower in Sevo-Op [85 (± 6.54) vs. 97.69 (± 7.8) mmHg, p = 0.0009]. Time to extubation was longer in Sevo-Dex [37.69 (10-70) vs. 19.63 (10-25), p = 0.0033]. No differences were found for the other intra-operative and post-operative variables investigated. Post-operative hypertension and agitation were the most common complications (11 and 12 out of 21 animals, respectively). These results suggest that the infusion of dexmedetomidine provides similar intra-operative conditions and post-operative course to a short acting opioid infusion during sevoflurane anesthesia in dogs undergoing elective rostrotentorial or transfrontal intracranial surgery.

SCR facility design for the selective catalyst performance of mixed gas

  • Woohyeon, Hwang;Kyung-Ok, Lee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.1
    • /
    • pp.121-127
    • /
    • 2023
  • In this study, the design conditions and CFD analysis results are compared and reviewed in SCR that can optimally reduce nitrogen compounds. To this end, it was analyzed and compared using CFD to see if the design criteria were satisfied for the shell and tube areas of the boiler. In the SCR system, the analysis area is the gas/air heat exchanger on the shell side, and eight tubes of the gas/air heat exchanger on the tube side. Through CFD analysis, the gas velocity distribution on the primary catalyst side of the SCR system was designed to be 2.4%, and the NH3/NOx molar ratio distribution was 3.7%, which satisfied the design criteria. In addition, the uniformity of the temperature distribution was confirmed and the required condition of 260℃ or higher was satisfied. The angle of the gas entering the catalyst met the design conditions at 2.9 degrees, and the pressure loss that occurred also satisfied the design requirements. Through this CFD analysis, it was confirmed that it was designed and operated by satisfying the design conditions required for each area.

Antenatal Care Services and Incidence of Low Birth Weight: A Comparison of Demographic and Health Surveys in 4 ASEAN Countries

  • Miftahul, Arsyi;Besral, Besral;Milla, Herdayati;Revati, Phalkey
    • Journal of Preventive Medicine and Public Health
    • /
    • v.55 no.6
    • /
    • pp.559-567
    • /
    • 2022
  • Objectives: This study aimed to assess the effect of complete coverage and content of available antenatal care (ANC) on the incidence of low birth weight (LBW) in 4 countries belonging to the Association of Southeast Asian Nations (ASEAN). Methods: Measures of complete coverage and content of ANC services included the frequency of ANC visits and the seven service components (blood pressure measurement, iron supplementation, tetanus toxoid immunization, explanations of pregnancy complications, urine sample test, blood sample test, and weight measurement). The complete coverage and content of ANC services were assessed as high if more than 4 ANC visits and all seven components were delivered. Multivariable logistic regression with complex survey designs was conducted using Demographic Health Survey data from the 4 ASEAN countries in question from 2014 to 2017. Results: The proportion of LBW infants was higher in the Philippines (13.8%) than in Indonesia (6.7%), Cambodia (6.7%), or Myanmar (7.5%). Poor ANC services were associated with a 1.30 times higher incidence of LBW than a high level of complete coverage and content of ANC services (adjusted odds ratio [aOR], 1.30; 95% confidence interval [CI], 1.11 to 1.52). In addition, the risk of LBW was higher in the Philippines than in other countries (aOR, 2.25; 95% CI, 2.01 to 2.51) after adjusting for mothers' demographic/socioeconomic factors, health behaviors, and other factors. Conclusions: In sum, complete coverage and content of ANC services were significantly associated with the incidence of LBW in Indonesia, Cambodia, and Myanmar. The Philippines did not show statistically significant results for this relationship, but had a higher risk of LBW with poor ANC.

The Size Distribution of Free Water Paths in Heartwood of Softwood by Centrifugal Method - The Difference between Earlywood and Latewood - (원심법에 의한 침엽수 심재부 유효수분이동경로의 반경분포 - 조재와 만재의 비교 -)

  • Park, Jong Su;Chun, Su Kyoung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.61-70
    • /
    • 2003
  • The size distribution of the free water paths between earlywood and latewood for six species in the heartwood of softwoods was estimated from the amount of dehydrated free water under various centrifugal fields, such as 2,200, 3,300, 4,800 and 6,900 rpm. The centrifugal method is based on the concept that water movement occurs by the balance of centrifugal force and water potential by meniscus. Water stops where the pressure differential is zero. In the centrifugal field, only two factors affect water movement in wood, that is, centrifugal force and water potential. Also, the water permeability was evaluated from the relationship between the water saturation ratio after the centrifugal treatment and the measure of water potential in specimen. The results showed that Cryptpmeria japonica had clear peaks at 0.70 ㎛ in earlywood and at 0.50 ㎛ in latewood. Tsuga sieboldii and Larix kaemferi had peaks at 0.50 and 0.30 ㎛ in both earlywood and latewood, respectively. Abies firma showed peaks at 0.70 ㎛ in earlywood and at 0.30 ㎛ in latewood. The water permeability of earlywood was higer than that of latewood for all softwoods except Pseudotsuga menziesii.