• Title/Summary/Keyword: pressure injection

Search Result 2,438, Processing Time 0.03 seconds

A study on the application of DOE for optimization of blending oil with non-esterified biodiesel fuel at partial engine load (부분부하에서 비에스테르화 바이오디젤 5% 혼합유의 성능최적화를 위한 실험계획법 적용에 관한 연구)

  • Kim, Hee-Jung;Koh, Dae-Kwon;Yang, Ju-Ho;Koh, Sung-Wi;Kim, Yeong-Sik;Jeong, Tae-Young;Jung, Suk-Ho
    • Journal of Power System Engineering
    • /
    • v.20 no.2
    • /
    • pp.51-57
    • /
    • 2016
  • Non-esterified biodiesel fuel is cheaper than esterified that because of a simple manufacturing process that only consists of filtering. Applicability of this on diesel engine with electronic control system was accomplished, then optimization adopting a fractional factorial design and response surface methodology was carried out at 25% and 50% of engine load in this study. Pressure of common rail and injection timing mainly effected on responses as specific fuel oil consumption and nitrogen oxides regardless of engine load. Estimations were 310.3 g/kWh of specific fuel oil consumption and 237 ppm of nitrogen oxides at 25% load, and 233.2 g/kWh of specific fuel oil consumption and 730 ppm of nitrogen oxides at 50% load. Tests to verify these estimations were accomplished and as the results, specific fuel oil consumption was 300.4 g/kWh and NOx was 277 ppm at 25% load and 236.8 g/kWh and 573 ppm at 50% load.

A Study on the Characteristics of Ignition and Combustion, in a Diesel Spray Using Multi-Component Mixed Fuels (다성분 혼합연료를 이용한 디젤분무의 착화연소특성에 관한 연구)

  • Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.120-127
    • /
    • 2007
  • The purpose of this study is experimentally to analyze that the fuel mass fractions of multi-component mixed fuels have an effect on the characteristics of spray ignition and combustion under the ambient conditions of diesel combustion fields. The characteristics of ignition and combustion were investigated by chemiluminescence images and direct photography. The experiments were conducted in the RCEM(rapid compression expansion machine) with optical access. Multi-component fuels mixed with i-octane, n-dodecane and n-hexadecane are injected in RCEM by the electronic control of common rail injector. Experimental conditions set up 42, 72 and 112 MPa in injection pressure, 700, 800 and 900 K in ambient gas temperature. The results show that the ignition delay was dependent on high cetane number. In case of low ambient temperature, the more low boiling point fuels were mixed, the lower luminance regime had a remarkable effect and also shortened diffusion combustion by increasing heat release rate.

Numerical Investigation of Factors affecting Photoresist Stripping Process on the ITO Surface using the Spray Method (노즐 분사 방식의 ITO 표면 포토레지스트 박리과정 요인의 수치해석)

  • Kim, Joon Hyun;Lee, Joon Hyuck;Kang, Tae Seong;Joo, Gi-Tae;Kim, Young Sung;Jeong, Byung Hyun;Lee, Dae Won
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.26 no.2
    • /
    • pp.158-165
    • /
    • 2017
  • This study investigated spraying factors applicable to stripper usage. Cyclodextrine, as environment-friendly material, was included in the stripper composition. An efficient spray technology was applied for the Photoresist strip. For industrial applications, stripping requires a temperature below $50^{\circ}C$, a strip time within 50 s, and chemically stable activation. Spraying factors were organized considering many conditions-orifice diameter, working pressure (inlet speed), spray distance, and spray angle. For commercial practicability, the flow rate was limited to 3 L/min. The nozzle parameters were nozzle orifice diameter of 1.8-2.2 mm, spray distance of 40-60 mm, and injection speed of 0.7-1.2 m/s. Through the thermal spray movement of the fluid, the thermal boundary layer for a chemical reaction just above the ITO-glass surface and momentum region for sufficient agitation (above 4 m/s) was achieved.

Intracordal Cartilage Injection For Vocal Fold Augmentation : Results for 2 Years

  • Lee, Byung-Joo;Wang, Soo-Geun;Goh, Eui-Kyung;Chon, Kyon-Myong;Roh, Hwan-Jung;Lee, Il-Woo
    • Proceedings of the KSLP Conference
    • /
    • 2003.11a
    • /
    • pp.181-181
    • /
    • 2003
  • Objectives : Vocal fold augmentation using injectable material is an easy and simple operation. This study is to evaluate the histology of minced and injected autologous auricular cartilage and fat graft in the augmentation of unilateral vocal fold paralysis using a canine model for two years. Study Design : A prospective study with the contralateral side of the larynx used as the control Methods : Twelve dogs were operated. At first, a piece of auricular cartilage was harvested from ear and minced into tiny chips with a scalpel and scissors. And also, a piece of fat tissue was harvested from inguinal area and minced into tiny chips with a scalpel and scissors. The minced cartilage and fat-paste (0.2ml) was injected using a pressure syringe into the paralyzed thyroarytenoid muscle under direct laryngoscopy. Two animals were sacrificed at 3 days, three at 3 weeks. two at 3 months. one at 6 months, one at 12 months, three at 24 months. Each dog underwent laryngectomy and serial coronal sections of paraffin blocks from the posterior part of the vocal fold were made. Result : There was no significant complication perioperatively and during follow-up. There was acute inflammatory findings in the graft at 3 days and 3 weeks. Only a very small proportion of the injected cartilage was absorbed due to the degenerative change and the overall volume was preserved even when the cells died out. The injected cartilage remained in the larynx until 24 months. Conclusion : The autologous cartilage implant using auricular cartilage was the ideal vocal cord augmentative material for the treatment of glottic incompetence.

  • PDF

Study on the Spray Behavior from Swirl and Fan Spray Type Gasoline Injectors Impinging on the Constant Temperature Flat Plate (스월형 및 팬스프레이형 고압직분식 가솔린 분사기의 상온 평판에서의 분무 충돌 특성에 관한 연구)

  • Kim, Chong-Min;Kang, Shin-Jae;Kim, Man-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.2
    • /
    • pp.100-106
    • /
    • 2006
  • The behavior of spray impinging on the inclined constant temperature flat plate was experimentally investigated. To clarify the wall effect of a high pressure DISI injector, a relative angle of the inclined wall to a spray axis was varied. Spray penetration along the wall was observed optically and it was compared with that of a Fan spray type and Swirl type spray. To evaluate various spray motion quantitatively, a spray path penetration which describe the development of a spray tip along the wall was newly introduced. To observe the structure of an impinging spray, it was visualized by a controlled stroboscope light and its visualized image was captured on an CCD camera. Using the digital image of impinging spray $H_x$ and $R_x$ was extracted to clarify the structure of impinging spray. The main parameter of the relative position of the wall was the inclined angle which was defined as the angle was varied from $0^{\circ}$ (vertical impingement) to $60^{\circ}$ at the same condition.

Fault Reactivation Modeling Using Coupled TOUGH2 and FLAC3D Interface Model: DECOVALEX-2019 Task B (TOUGH2-FLAC3D Interface 모델을 통한 단층 재활성 모델링: DECOVALEX-2019 Task B)

  • Park, Jung-Wook;Park, Eui-Seob;Lee, Changsoo
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.335-358
    • /
    • 2020
  • We present a numerical model to simulate coupled hydro-mechanical behavior of fault using TOUGH-FLAC simulator. This study aims to develop a numerical method to estimate fluid injection-induced fault reactivation in low permeability rock and to access the relevant hydro-mechanical stability in rock as part of DECOVALEX-2019 Task B. A coupled fluid flow and mechanical interface model to explicitly represent a fault was suggested and validated from the applications to benchmark simulations and the field experiment at Mont Terri underground laboratory in Switzerland. The pressure build-up, hydraulic aperture evolution, displacement, and stress responses matched those obtained at the site, which indicates the capability of the model to appropriately capture the hydro-mechanical processes in rock fault.

General Pharmacology of SB-31$\circledR$ (SB-31$\circledR$의 일반약리작용)

  • 박우규;천혜경;권경자;윤여생;신화섭;공재양
    • Biomolecules & Therapeutics
    • /
    • v.5 no.4
    • /
    • pp.369-375
    • /
    • 1997
  • General pharmacological effects of SB-31$^{R}$, the extracts of Pulsatilla koreana, were investigated in mice, rats and guinea-pigs. Intravenous injection of SB-31 (3 and 6 ml/kg) produced almost no effect on central nervous system no effects on the general symptom and behaviors of mice, spontaneous locomotor activity, pentobarbital- induced sleeping time , rotared performance , electroshock and pentylenetertrazole -induced seizures, acetic acid-induced writhing and normal body temperature in mice. SB-31 showed little effects on the spontaneous movement of the isolated ileum and contraction induced by agonists in isolated ileum, suggesting no influence on autonomic nervous system. Administration of SB-31 also did not show any effect on blood pressure in conscious rats. However, a slight decrease in heart rate was observed at high doses (6 and 10 ml/kg) of SB-31 in conscious rats. Similarly, a slight increase in respiratory rate was observed at 6 m1/kg of SB-31 in anesthetized rats. SB-31 did not produce any effect at the dose of 3 ml/kg, but showed a tendency to increase the urinary volume at 6 ml/kg, and produced a decrease in urinary excretions of N $a_{+}$and $K_{+}$at 6 ml/kg. However, transport capacity within the gastrointestinal tract and the secretion of the gastric juice were not influenced by 6 ml/kg of SB-31. In conclusion, these results suggest that SB-31 did not pro-duce any acute effects on the central nervous system, autonomic nervous system, respiratory and circulatory systems, digestive system and kidney function at the dose of below 3 ml/kg.ml/kg.

  • PDF

Development and Application of Micromodel for Visualization of Supercritical CO2 Migration in Pore-scale (공극 규모에서의 초임계상 이산화탄소 거동 가시화를 위한 마이크로모델의 개발과 적용)

  • Park, Bogyeong;Lee, Minhee;Wang, Sookyun
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.4
    • /
    • pp.73-82
    • /
    • 2015
  • Despite significant effects on macroscopic migration and distribution of CO2 injected during geological sequestration, only limited information is available on wettability in microscopic scCO2-brine-mineral systems due to difficulties in pore-scale observation. In this study, a micromodel had been developed to improve our understanding of how scCO2 flooding and residual characteristics of porewater are affected by the wettability in scCO2-water-glass bead systems. The micromodel (a transparent pore structure made of glass beads and glass plates) in a pressurized chamber provided the opportunity to visualize scCO2 spreading and porewater displacement. CO2 flooding followed by fingering migration and dewatering followed by formation of residual water were observed through an imaging system. Measurement of contact angles of residual porewater in micromodels were conducted to estimate wettability in a scCO2-water-glass bead system. The measurement revealed that the brine-3M NaCl solution-is a wetting fluid and the surface of glass beads is water-wet. It is also found that the contact angle at equilibrium decreases as the pressure decreases, whereas it increases as the salinity increases. Such changes in wettability may significantly affect the patterns of scCO2 migration and porewater residence during the process of CO2 injection into a saline aquifer at high pressures.

Studies on Voice Changes Associated with Alcohol Intake (음주에 따른 음성 변화에 대한 고찰)

  • Kim, Jung-Hyun;Yoon, Je-Hwan;Cho, Hyung-Ho;Cho, Yeon;Cho, Jae-Sik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.18-22
    • /
    • 2002
  • Background and Objectives : It has been pointed out that alcohol intake in human beings induces changes in voice register and maximum phonation time. These changes supposedly result from injection of the vibratory vocal folds. The purpose of this study was to clarify the voice changes associated with alcohol intake and the changes of laryngeal mucosa. Materials and Methods : The subjects included 29 volunteers, including 20 men and 9 women ranging in age from 22 to 31 years. Alcohol intake was accomplished by oral administration of 23% soju 1 bottle (255cc). Serum alcohol concentration levels were evaluated hourly for 3 h after ingestion of alcohol. Seven measurements were performed at pre-alcohol intake and post-alcohol intake hourly : fundamental frequency, jitter, shimmer, noise to harmonic ratio as the acoustic analysis, maximal phonation time, mean flow rate, and subglottal pressure as the aerodynamic analysis. The changes of laryngeal mucosa were evaluated by flexible laryngoscope at each measurement. Results : By comparing the acoustic and aerodynamic data and laryngeal mucosa before and after alcohol intake, there were not remarkable changes (p>0.05). Conclusion : The voice and laryngeal mucosa have not remarkably changed according to alcohol concentration in this study. Furthermore studies on the voice change induced by multiple alcohol concentrations are required.

  • PDF

Performance Characteristics of Thrust Measurement System for Hot-Firing Test of Small Liquid Propulsion Engines (소형 액체 추진기관 연소 시험을 위한 추력 측정 장치의 성능 특성 연구)

  • Kim, In-Tae;Huh, Hwan-Il;Kim, Jeong-Soo;Jang, Ki-Won;Lee, Jae-Won
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.9
    • /
    • pp.122-129
    • /
    • 2004
  • An accurate thrust measurement is one of the critical paths to the successful test and evaluation program of small liquid propulsion engines. This study describes the design factors for the development of thrust measurement system (TMS) as well as manufacturing practice of TMS hardware. We investigate characteristics of the TMS and its performance through hot-firing test of small liquid engine in a vacuum test cell which is capable of simulating 100,000 ft of altitude or higher. For performance test of TMS, we measure thrusts by changing propellant injection pressure at steady state firing mode as well as at pulse firing mode. Measured eigen frequency of the TMS is 67 Hz. Linearity test of the TMS shows good performance with less than 0.5% of linearity error.