• Title/Summary/Keyword: pressure injection

Search Result 2,438, Processing Time 0.026 seconds

ROSA/LSTF test and RELAP5 code analyses on PWR 1% vessel upper head small-break LOCA with accident management measure based on core exit temperature

  • Takeda, Takeshi
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1412-1420
    • /
    • 2018
  • An experiment was performed using the large-scale test facility (LSTF), which simulated a 1% vessel upper head small-break loss-of-coolant accident with an accident management (AM) measure under an assumption of total-failure of high-pressure injection (HPI) system in a pressurized water reactor (PWR). In the LSTF test, liquid level in the upper head affected break flow rate. Coolant was manually injected from the HPI system into cold legs as the AM measure when the maximum core exit temperature reached 623 K. The cladding surface temperature largely increased due to late and slow response of the core exit thermocouples. The AM measure was confirmed to be effective for the core cooling. The RELAP5/MOD3.3 code indicated insufficient prediction of primary coolant distribution. The author conducted uncertainty analysis for the LSTF test employing created phenomena identification and ranking table for each component. The author clarified that peak cladding temperature was largely dependent on the combination of multiple uncertain parameters within the defined uncertain ranges.

Morphology and Dynamical Properties of Ultra-Relativistic Jets

  • Seo, Jeongbhin;Kang, Hyesung;Ryu, Dongsu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.37.2-37.2
    • /
    • 2020
  • We study the structures and dynamics of flows generated by ultra-relativistic jets on kpc scales through three-dimensional relativistic hydrodynamics (RHD) simulations. We employ a newly developed RHD code, equipped with the WENO-Z reconstruction, the SSPRK time discretization, and an equation of state that closely approximates the single-component perfect gas in relativistic regime. Exploring a set of models with various parameters, we confirm that the well-known Fanaroff-Riley dichotomy is primarily determined by the jet power, whereas the morphology of simulated jets also depends on the secondary parameters such as the momentum injection rate and the ratio of the jet to background pressure. Utilizing high resolution capabilities of the newly developed code, we examine in detail the dynamical properties of complex flows in different parts of jet-produced structures, and present the statistics of nonlinear dynamics such as shock, shear, and turbulence.

  • PDF

Ultrasonography-Guided Common Musculoskeletal Interventions from Head to Toe: Procedural Tips for General Radiologists

  • Roland White;Michael Croft;Stephen Bird;Matthew Sampson
    • Korean Journal of Radiology
    • /
    • v.22 no.12
    • /
    • pp.2006-2016
    • /
    • 2021
  • The expanding scope of interventional musculoskeletal procedures has resulted in increased pressure on general radiologists. The confidence of general radiologists in performing ultrasound-guided musculoskeletal procedures varies with their clinical exposure. This didactic review provides a methodologically and clinically oriented approach to enhancing user understanding and confidence in performing ultrasound-guided musculoskeletal procedures. The body of the text is accompanied by figures depicting the procedural approach, injection site, and labeled ultrasonography images. This paper aims to provide a teaching and bedside aid for education on and the execution of musculoskeletal procedures to ensure the provision of quality health care.

UHPLC System Shutdown and Reactivation Advice (UHPLC 시스템 종료 및 재가동 시 가이드)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

A Study on the Post Processing of Flash Boiling Spray Image from Shadowgraphy (감압비등 분무의 역광이미지 후처리 기법에 관한 연구)

  • Hyunchang Lee
    • Journal of ILASS-Korea
    • /
    • v.29 no.2
    • /
    • pp.91-97
    • /
    • 2024
  • When investigating the droplet, spray, and impact of liquid on a solid plate, backlight imaging has been widely used to understand these phenomena. However, some previous studies have suffered from poor image quality. In this study, various combinations of image processing algorithms, such as white image correction, histogram equalization, CLAHE, Otsu's binarization, and multi-Otsu's binarization, have been applied to flash boiling spray images to enhance image quality for qualitative observation and semi-quantitative spray angle evaluation. To acquire images with high contrast for qualitative observation, applying CLAHE was effective, making small droplets and detailed shapes of the jet noticeable. However, when images were averaged to determine spray angle or penetration length based on intensity, this method induced artifact unphysical patterns, thus requiring careful consideration. Based on the algorithm proposed in this study, the spray angle variation according to injection pressure and temperature has been calculated, showing a reasonable trend.

A Study on the Conditions of Injection Pressurization in the Smoke-Control Zone II. Analysis of the Conditions for Closing Force of Fire Door with Variation of Angular Velocity (제연구역 방화문의 각속도 변화와 폐쇄 조건 분석)

  • Lee, Chang-Wook;Kim, Hong-Jin;Choi, Young-Ki;Youm, Moon Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.6-10
    • /
    • 2013
  • This study aims to construct the performance data for smoke-control zone and realize the safety of injection and pressurization room which is composed of supply air pressure zone, vestibule, smoke-control zone and stairwell. To obtain this, smoke-control system and the device of the opening-closing force of fire door are manufactured. This subject is the analysis of the closing force, angular velocity and fire door size in the case of fixed volume flow rate. Based on the results, closing force increased as fire door size and closing angular velocity increases. Also, it is remark that there exists a critical angular velocity, which maintains constant maximum closing force even though the angular velocity increases more.

pH Control of Feed Water for HRSG with Additional Injection of NH3 (암모니아 추가 주입에 의한 배열회수보일러 급수의 수소이온농도 조절)

  • Mok, Yong-kang;Moon, Seung-Jae;Lee, Jae-Heon
    • Plant Journal
    • /
    • v.11 no.2
    • /
    • pp.32-38
    • /
    • 2015
  • This study was conducted on combined cycle power plant consisting of HRSG with integral deaerator type to avoid tube failures of low pressure evaporator tubes. Based on the observation of pH variation at the discharge of boiler feed water pump by continuous pH measurement for a period of time, it was identified that pH of feed water is getting reduced as ammonia is distributed into vapor and liquid depending on the distribution ratio of ammonia in the LP drum after the deaerator. To solve this problem, the counterplan was prepared by reexamination of ammonia injection point and quantity. In conclusion, it was accomplished that 9.2~9.6 is the optimized pH range for boiler feed water by arranging additional piping for ammonia to inject directly to LP drum.

  • PDF

Study on the cooling water supply method to the cooling water injection nozzle in the steam generator (증기발생기 내 냉각수 분사 노즐로의 냉각수 공급 방법에 관한 연구)

  • Oh, Jeong-hwa;Shin, Min-kyu;Cho, Young-seok;Ko, Young-sung
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.66-72
    • /
    • 2020
  • In this study, a method for increasing the initial water supply was employed to protect the water injection nozzle by the flame when supplying the water to the steam generator. During the initial steam generator test, the flow rate was controlled by using the only venturi, but cooling water was not supplied to the combustion chamber at the beginning of combustion, thereby resulting in damage to the water nozzle. To solve this problem, a venturi and an orifice were configured in parallel to increase the initial supply flow rate to form a differential pressure between the water manifold and the combustion chamber. Venturi and orifice supply sequences were established through the water flow tests, and combustion tests were conducted for final verification. Consequently, a continuous supply of the cooling water at the beginning of combustion was achieved, and the experiment was successfully performed without damaging the cooling water nozzle.

Analysis of ground reinforcement effect using fracturing grouting (침투 및 할렬주입에 의한 지반보강 효과에 관한 연구)

  • Lee, J.S.;Lee, I.M.;Chung, H.S.;Lee, D.S.
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.4
    • /
    • pp.349-360
    • /
    • 2003
  • A practical modeling approach has been proposed in this study to better understand the behavior of penetration grouting which is normally applied to the jointed rock masses to increase the bearing capacity and to reduce the ground water flow into the tunnel. Based on Bingham model together with a steady-state flow of the grout, penetration model is simulated in the commercial package called UDEC and, injection pressure as well as joint thickness are found to be the main parameters to determine the range of grout spread. Another numerical model on fracturing grouting is also suggested and, in this case, the tensile strength as well as cohesion of the rock masses are proven to be the major factors to decide the fracturing mechanism of the rock masses. The reinforcement effect of the grout-reinforced rock masses is calculated from the suggested algorithm on orthotropic material model and it is found that the directional stiffness of reinforced rock masses is increased up to 3 to 4 times compared with original jointed rock masses. Future work will be concentrated on the water control around the tunnel by the grout injection and a model test will also be performed to verify the suggested methods developed in this study.

  • PDF

Study on the Atomization Characteristics of a Counter-swirling Two-phase Atomizer with Variations of Swirl angle (역선회 이류체 미립화기의 선회각 변화에 따른 미립화 특성연구)

  • Kim, N.H.;Lee, S.G.;Ha, M.H.;Rho, B.J.;Kang, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.125-130
    • /
    • 2001
  • Experimental and analytical researches have been conducted on the twin-fluid atomizers for better droplet breakup during the past decades. But, the studies on the disintegration mechanism still present a great challenge to understand the drop behavior and breakup structure. In an effort to describe the aerodynamic behavior of the sprays issuing from the internal mixing counter-swirling nozzle, the spatial distribution of axial (U) radial (V) and tangential (W) components of droplet velocities are investigated across the radial distance at several axial locations of Z=30, 50, 80, 120 and 170mm, respectively. Experiments were conducted for the liquid flow rates which was kept constant at 7.95 g/s and the air injection pressures were varied from 20 kPa to 140 kPa. Counter-swirling internal mixing nozzles manufactured at angles of $15^{\circ},\;30^{\circ},\;45^{\circ}$ and $60^{\circ}$ the central axis with axi-symmetric tangential-drilled holes was considered. The distributions of velocities and turbulence intensities are comparatively analyzed. PDPA is installed to specify spray flows, which have been conducted along the axial downstream distance from the nozzle exit. Ten thousand of sampling data was collected at each point with time limits of 30 second. 3-D automatic traversing system is used to control the exact measurement. It is observed that the sprays with all swirl angle have the maximum SMD for on air injection pressure of 20 kPa and 140 kPa with centerline, respectively. The nozzle with swirl angle of $60^{\circ}$ has vest performance.

  • PDF