• Title/Summary/Keyword: pressure data

Search Result 7,295, Processing Time 0.043 seconds

Analysis of Degradation Behaviors of Geomembrane by Accelerated Test under UV Exposure Conditions (자외선 노출조건 하에서 가속시험에 의한 지오멤브레인의 분해거동 해석)

  • Park, Yeong Mog;Khan, Belas Ahmed;Jeon, Han Yong
    • Polymer(Korea)
    • /
    • v.37 no.1
    • /
    • pp.5-14
    • /
    • 2013
  • In this paper the effect of UV (ultraviolet) exposure on HDPE (high density polyethylene)-smooth and f-PP (flexible polypropylene) geomembranes is evaluated under UVB-313 (ultraviolet wavelength 290-315 nm) exposure. Tensile property, melt flow index (MFI), oxidation induction time (OIT), both standard-OIT and high pressure-OIT and Fourier transform infrared spectroscopy/attenuated total reflectance (FTIR/ATR) results are discussed. Although tensile properties of the exposed geomembrane samples remained unchanged, the depletion of antioxidants was found higher for f-PP than for HDPE geomembrane. Arrhenius model by extrapolation was used on the data to predict the antioxidant lifetime to a typical site temperature of $20^{\circ}C$. There was no significant difference between the MFI value of the virgin and UV exposed HDPE geomembrane samples but a decrease in MFI was found in f-PP geomembrane that signifies that crosslinking has occurred. From FTIR spectra, the small peak (near $1750\;cm^{-1}$) observed in the spectrum of UV exposed sample corresponds to a carbonyl (C=O) linkage, which suggests that oxidation has occurred in the polymer structure, and another new band for f-PP between 3100 and $3500\;cm^{-1}$ is attributed to a hydroxyl bond and/or hydroperoxide bond.

Comparative Experiments to Assess the Effects of Accumulator Nitrogen Injection on Passive Core Cooling During Small Break LOCA

  • Li, Yuquan;Hao, Botao;Zhong, Jia;Wang, Nan
    • Nuclear Engineering and Technology
    • /
    • v.49 no.1
    • /
    • pp.54-70
    • /
    • 2017
  • The accumulator is a passive safety injection device for emergency core cooling systems. As an important safety feature for providing a high-speed injection flow to the core by compressed nitrogen gas pressure during a loss-of-coolant accident (LOCA), the accumulator injects its precharged nitrogen into the system after its coolant has been emptied. Attention has been drawn to the possible negative effects caused by such a nitrogen injection in passive safety nuclear power plants. Although some experimental work on the nitrogen injection has been done, there have been no comparative tests in which the effects on the system responses and the core safety have been clearly assessed. In this study, a new thermal hydraulic integral test facility-the advanced core-cooling mechanism experiment (ACME)-was designed and constructed to support the CAP1400 safety review. The ACME test facility was used to study the nitrogen injection effects on the system responses to the small break loss-of-coolant accident LOCA (SBLOCA) transient. Two comparison test groups-a 2-inch cold leg break and a double-ended direct-vessel-injection (DEDVI) line break-were conducted. Each group consists of a nitrogen injection test and a nitrogen isolation comparison test with the same break conditions. To assess the nitrogen injection effects, the experimental data that are representative of the system responses and the core safety were compared and analyzed. The results of the comparison show that the effects of nitrogen injection on system responses and core safety are significantly different between the 2-inch and DEDVI breaks. The mechanisms of the different effects on the transient were also investigated. The amount of nitrogen injected, along with its heat absorption, was likewise evaluated in order to assess its effect on the system depressurization process. The results of the comparison and analyses in this study are important for recognizing and understanding the potential negative effects on the passive core cooling performance caused by nitrogen injection during the SBLOCA transient.

Molecular Epidemiology of Metallo-β-lactamase Producing Pseudomonas aeruginosa Clinical Isolates (임상에서 분리된 Metallo-β-lactamase 생성 Pseudomonas aeruginosa의 분자역학)

  • Choi, Myung-Won
    • Journal of Life Science
    • /
    • v.22 no.9
    • /
    • pp.1268-1276
    • /
    • 2012
  • The emergence and dissemination of carbapenem-resistant bacteria have resulted in limitations of antibiotic treatment and potential outbreaks of metallo-${\beta}$-lactamase (MBL) producing Pseudomonas aeruginosa resistant to carbapenems. In this study, we conducted molecular characterization of the MBL genes of the ${\beta}$-lactam drug-resistant P. aeruginosa and prepared basic data for treatment and prevention of proliferation of antimicrobial-resistant bacterial infections. Forty-two P. aeruginosa isolates of 254 were resistant to imipenem or meropenem. Among the 42 isolates, 28 isolates were positive for the Hodge test, and 23 isolates were positive for the EDTA-disk synergy test (EDST). MBLs were detected in 59.5% (25/42) of P. aeruginosa isolates. Eight isolates harbored $bla_{IMP-6}$, whereas 17 isolates harbored $bla_{VIM-2}$. The $bla_{IMP-6}$ gene was in a class 1 integron containing five gene cassettes: $bla_{IMP-6}$, qac, aacA4, $bla_{OXA-1}$, and aadA1. Some strains that produce IMP-6 and VIM-2 showed epidemiological relationships. The $bla_{IMP-6}$ gene in carbapenem-resistant P. aeruginosa showed an identical pattern to a gene cassette that was reported at a hospital in Daegu, Korea. Therefore, MBL-producing P. aeruginosa is already endemic in the community. We are concerned that the existence of carbapenem-resistant bacteria containing the blaMBL gene may increase pressure on antibiotic selection when treating infections. We believe that we should select appropriate antibiotics based on the antibiotic susceptibility test and continue the research to prohibit the emergence and spread of antibiotics resistant bacteria.

Interaction between Renin-Angiotensin and Endothelium-Derived Nitric Oxide Systems in Two-Kidney, One Clip Hypertensive Rats

  • Ahn, Hyun-Tack;Nah, Kook-Joo;Lee, Jong-Un
    • The Korean Journal of Physiology
    • /
    • v.30 no.1
    • /
    • pp.33-41
    • /
    • 1996
  • The present study was aimed to investigate the role of endothelium-derived nitric oxide (NO) in the control of renin release and to examine if NO is implicated in the development of two-kidney, one clip (2K1C) hypertension. Male Sprague-Dawley rats $(150{\sim}200\; g)$ were constricted at the left renal artery. They were then supplemented with $N^{G}-nitro-L-arginine\;methyl\;ester\;(L-NAME,\; 5mg/100\;mL)$ or with L-arginine hydrochloride (400 mg/100 mL) in the drinking water. The control group was supplied with normal tap water. The sham-clipped rats were operated as in 2K1C rats except for that no clip was made. The kidneys were taken to examine in vitro release of renin at days 7 and 14 following clipping the renal artery. Northern blot analysis was also done to assess the expression of renin gene in the kidney. In sham-clipped rats, L-NAME caused a sustained increase of the blood pressure, whereas L-arginine was without effect. Neither L-NAME nor L-arginine-supplementation significantly affected the development of hypertension in 2K1C rats. Plasma renin concentration (PRC) measured on day 28 did not significantly differ among the L-NAME, L-arginine and control groups either in 2K1C or in sham-clipped rats. Renin contents (RRC) in the clipped kidney were increased, while those in the contralateral kidney were decreased. The release of renin in vitro from cortical slices was also enhanced in the clipped kidney, whereas it was attenuated in the contralateral. Comparing the RRC and in vitro release, the latter was more rapidly decreased than the former in the contralateral kidney. The renin mRNA levels in the contralateral kidney were almost at their nadir at days 7 and 14 in 2K1C rats. It is suggested that NO does not affect the development of 2K1C hypertension in which the renin-angiotensin system has been activated. The data also confirm that RRC and renin gene expression are increased in the clipped kidney and suppressed in the contralateral kidney in 2K1C rats.

  • PDF

Correlations in Appearance, Job-seeking Stress and Job-seeking Anxiety in Undergraduates according to Gender Differences (대학생의 성별에 따른 외모와 취업 스트레스 및 취업불안과의 관계)

  • Cho, Mi Kyoung;Choi, Eun Ji;Lee, Ji Won;Lee, Yu Na;Chae, Ji Young
    • Perspectives in Nursing Science
    • /
    • v.10 no.2
    • /
    • pp.141-150
    • /
    • 2013
  • Purpose: The purpose of this study was to evaluate the differences between the level of satisfaction and concern regarding appearance according to gender, the importance of appearance in job interviews, and the influence appearance has on job-seeking stress and anxiety under the ever-increasing pressure on students to secure employment so that appropriate psychological interventions can be provided to undergraduates. Methods: The survey was conducted on 170 third and fourth year undergraduates in Gyeonggi province from August 31st to September 6th, 2012 to figure out the correlations and differences in variables of appearance satisfaction and concern, and the importance of appearance in job interviews and job-seeking stress and anxiety according to the differences in gender. Data were analyzed by descriptive statistics, independent t-test, two-way ANOVA, and Pearson's correlation analysis. Results: 1. There was difference between the genders for appearance satisfaction and concern. The level of satisfaction was higher in male students while concerns regarding appearance were higher in female students. There was no gender difference regarding the importance of appearance in job interviews, job-seeking stress, and job-seeking anxiety. 2. For the concerns in appearance, there was a significant difference between the genders in appearance management, and gender and the importance of appearance in job interviews showed significant interactive effects. Stress and anxiety from job-seeking did not show significant differences between the genders, but there were common significant interactive effects between gender and grades, gender and employment, and gender and the importance of appearance in job interviews. 3. Both male and female students showed higher job-seeking stress as their job-seeking anxiety was higher. Job-seeking anxiety was higher in male students who had higher concern in appearance, and in female students who placed more emphasis on the importance of appearance in job interviews. Conclusion: As female students perceived appearance in job interviews as important more than male students, their job-seeking anxiety was higher, while male students who showed higher concern in appearance also showed higher level of anxiety in job-seeking. As job-seeking anxiety was higher, job-seeking stress was also higher according to the entire participants, based on this result, methods to decrease job-seeking anxiety should be suggested.

  • PDF

Multi-stage Membrane Process for $CO_2$ Separation from Flue Gas Using PES Hollow Fiber Membrane Modules (폴리이서설폰 중공사모듈을 이용한 연소배가스로부터 이산화탄소 분리회수를 위한 다단계 막분리공정 연구)

  • Choi Seung-Hak;Kim Jeong-Hoon;Kim Eeom-Sik;Lee Soo-Bok
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.310-319
    • /
    • 2005
  • This paper describes the preliminary study on the development of multi-stage membrane demonstration plant for removal of carbon dioxide from flue gas stream being emitted from LNG boiler in thermal power generation plant. The prerequisite requirement is to design and develop the membrane process producing a $99\%\;CO_2$ with $90\%$ recovery from LNG flue gas of 1,000 $Nm^3$/day. Asymmetric polyethersulfone hollow fiber membranes and membrane modules developed in this laboratory[1] were used in this study. Using the permeation data for the hollow fiber membranes, modelling on the membrane module and multi-stage membrane process was done to meet the requirement condition of the process design. The effects of the operating pressure of feed and permeate side and feed concentration on $CO_2$ purity and recovery were investigated experimentally with the developed hollow fiber modules. These experimental results matched well with theoretical modelling results.

The Effects of Substrate Bias Voltage on the Formation of $(ZnS)_{1-x}-(SiO_2)_x$ Protective Films in Phase Change Optical Disk by R.F. Sputtering Method. (R.F. 스퍼터링법에 의한 상변화형 광디스크의 $(ZnS)_{1-x}-(SiO_2)_x$ 보호막 제조시 기판 바이어스전압의 영향)

  • Lee, Tae-Yun;Kim, Do-Hun
    • Korean Journal of Materials Research
    • /
    • v.8 no.10
    • /
    • pp.961-968
    • /
    • 1998
  • In order to investigate the effects of substrate bias voltage on the formation of$ZnS-SiO_2$ protective film in phase change optical disk by R.F. magnetron sputtering method, thin dielectric film was formed on Si wafer and Corning glass by using ZnS(80mol%)-$SiO_2$(20mol%)t arget under argon gas. In this study, the Taguchi experimental method was applied in order to obtain optimum conditions with reduced number of experiments and to control numerous variables effectively. At the same time this method can assure the reproducibility of experiments. Optimum conditions for film formation obtained by above method were target RF power of 200 W. substrate RF power of 20 W, Ar pressure of 5 mTorr. sputtering time of 20 min.. respectively. The phase of specimen was determined by using XRD and TEM. The compositional analysis of specimen was performed by XPS test. In order to measure the thermal resistivity of deposited specimen, annealing test was carried out at $300^{\circ}C$ and $600^{\circ}C$. For the account of void fraction in thin film, the Bruggeman EMA(Effective Medium Approximation) method was applied using the optical data obtained by Spectroscopic Ellipsometry. According to the results of this work, the existence of strong interaction between bias voltage and sputtering time was confirmed for refractive index value. According to XRD and TEM analysis of specimen, the film structure formed in bias voltage resulted in more refined structures than that formed without bias voltage. But excess bias voltage resulted in grain growth in thin film. It was confirmed that the application of optimum bias voltage increased film density by reduction of void fraction of about 3.7%.

  • PDF

Meteorological Characteristics of High-Ozone Episode Days in Daegu, Korea (대구시의 고농도 오존 발생 일에 나타나는 기상학적 특성)

  • Son, Im-Young;Kim, Hee-Jong;Yoon, Ill-Hee
    • Journal of the Korean earth science society
    • /
    • v.23 no.5
    • /
    • pp.424-435
    • /
    • 2002
  • This study analyzes the surface ozone and meteorological data in Daegu for a period from 1997 to 1999. It also investigates the meteorological characteristics of high ozone episodes. For this study the high ozone episode has been defined as a daily maximum ozone concentration higher than 100ppb in at least one station among six air quality monitoring stations in Daegu, Korea. The frequency of episodes is 13 days. The frequency is the highest in May and September. The average value of daily maximum ozone concentration is 81.6ppb, and 8-hour average ozone concentration is 58.6ppb for the high episodes. This shows that ozone pollution is continuous and wide-ranging in Daegu. The daily maximum ozone concentration is positively correlated to solar radiation and daily maximum temperature, but negatively correlated to relative humidity, wind speed and cloud amount. The maximal correlation coefficient to solar radiation is 0.45. The differences between high ozone episode day's daily mean meteorological value and monthly mean value are +1.58hPa for sea level pressure, +3.45${\circ}$C for maximum temperature, -5.69% for relative humidity, -0.46ms$^{-1}$ for wind speed, -1.79 for cloud amount, and +3.97MJm$^{-2}$ for solar radiation, respectively. This shows that strong solar radiation, low wind speed and no precipitation between 0700${\sim}$1100LST are favorite conditions for high ozone episodes. It is related to the morning stagnant condition.

Study on Preparation of Methyl N-Phenyl Carbamate by Oxidative Carbonylation of Aniline and Methanol (아닐린과 메탄올의 산화 카르보닐화에 의한 Methyl N-phenyl carbamate 제조 연구)

  • Roh, Jong-Seon;Lee, Kwan-Young;Kim, Tae-Soon;Chang, Tae-Seon;Yoon, Byung-Tae;Kim, Seong-Bo
    • Korean Chemical Engineering Research
    • /
    • v.56 no.1
    • /
    • pp.119-124
    • /
    • 2018
  • The production of methyl N-phenyl carbamate by an oxidative carbonylation method of aniline and methanol is of great interest as an environmentally friendly process that can replace the monomer production process of a polymer produce using conventional phosgene. In this study, heterogeneous catalysts were prepared by using Y-zeolite, $SiO_2$, $Al_2O_3$ as support, and oxidative carbonylation continuous operation from aniline and methanol was attempted using the prepared heterogeneous catalyst. Batch reactor was used to determine the support, and various reaction conditions such as reaction temperature, reaction pressure, and effect of promoter were established using palladium catalyst. A reaction kinetics study was conducted under optimum reaction conditions. The basic data for carbamate process development were obtained by performing continuous operation for a long time under established reaction condition.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.