• Title/Summary/Keyword: pressure data

Search Result 7,254, Processing Time 0.036 seconds

A Study on Pressure Drop Characteristics of Refrigerants in Horizontal Flow Boiling

  • Lim, Tae-Woo;Han, Kyu-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.758-765
    • /
    • 2003
  • An experimental investigation on the flow pattern and pressure drop was carried out for both an adiabatic and a diabatic two-phase flow in a horizontal tube with pure refrigerants R134a and R123 and their mixtures as test fluids. The observed flow patterns were compared to the flow pattern map of Kattan et al., which predicted well the present data over the entire regions of mass velocity in this study. The measured frictional pressure drop in the adiabatic experiments increased with an increase in vapor quality and mass velocity These data were compared to various correlations proposed in the past for the frictional pressure drop. The Chisholm correlation underpredicted the present data both for pure fluids and their mixtures in the entire mass velocity range of 150 to 600 kg/m$^2$s covered in the measurements, white the Friedel correlation was found to overpredict the present data in the stratified and stratified-wavy flow region, and to underpredict in the annular flow region.

The pressure control of SR Drive for Hydraulic Oil-pump with Data based PID Control (실험 데이터 기반의 PID 제어기를 적용한 유압펌프용 SRM의 압력제어)

  • Seok, Seung-Hun;Kim, Tae-Hyoung;Lee, Dong-Hee;Ahn, Jin-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.10a
    • /
    • pp.160-162
    • /
    • 2008
  • This paper presents the practical pressure control of hydraulic oil-pump system using SR drive for industrial application. In order to get a high performance of pressure dynamics in actual application, a data based PID control scheme is proposed in this paper. The look-up table from pre-measured data produces an approximately proper current reference according to motor speed and oil-pressure. And, PID controller can compensate the pressure error. With the combination of two references, the proposed control scheme can get a fast dynamics and stable operation. Furthermore, the suitable current controller considering the nonlinear characteristics of SRM(Switched Reluctance Motor) and practical test method for data measuring are introduced. The proposed control scheme is verified by the experimental test.

  • PDF

Calibration and Flight Test Results of Air Data Sensing System using Flush Pressure Ports (플러시 압력공을 사용한 대기자료 측정장치의 교정 및 비행시험 결과)

  • Lee, Chang-Ho;Park, Young-Min;Chang, Byeong-Hee;Lee, Yung-Gyo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.7
    • /
    • pp.531-538
    • /
    • 2017
  • A flush air data sensing system, which can predict flight speed, angle of attack, and angle of sideslip of the aircraft is designed and manufactured for a small UAV. Two kinds of flush pressure ports, four ports and five ports, are tapped at the same section of fuselage nose-cone. Calibration pressure data at flush ports are obtained through computations for the total aircraft by using Fluent code. Angle of attack, angle of sideslip, total pressure, and static pressure are represented with 4th-order polynomial function and calibration coefficient matrix is obtained using least square method with calibration pressure data. Flight test showed that flight speed, angle of attack, and sideslip angle predicted by four flush ports and five flush ports compared well with those by five-hole probe installed for data comparison. Especially four flush ports revealed nearly same results as those by five flush ports.

Thermodynamic Analysis of the Hammett Reaction Parameter and Free Energy Relationship for the Pressure Change

  • Hwang, Jung-Ui
    • Bulletin of the Korean Chemical Society
    • /
    • v.8 no.4
    • /
    • pp.237-242
    • /
    • 1987
  • Pressure dependance of Hammett reaction parameter was analyzed and the free energy relationship for the pressure change derived thermodynamically. There are insufficient data in the literature to test the relation derived but from some limited previous data it could be concluded that the parameter ${\rho}$ is dependent on pressure and increase or decrease as pressure increase for a given reaction series.

A Study on Pressure Drop in Two-Phase Flow Boiling of Refrigerants in Horizontal Tube (수평 전열관내 냉매의 이상유동 압력강하에 관한 연구)

  • 임태우;김준효
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.6
    • /
    • pp.510-517
    • /
    • 2003
  • An experimental study on the pressure drop during flow boiling for pure refrigerants R134a and Rl23, and their mixture was carried out in a uniformly heated horizontal tube. Tests were run at a pressure of 0.6 MPa and in the ranges of heat flux 5~50 kW/m$^2$, vapor quality 0~100 percent and mass velocity of 150~600 kg/m$^2$s. Generally, the two-phase frictional multiplier is used to predict the frictional pressure drop during the two-phase flow boiling. The obtained results have been compared to the existing various correlations for the two-phase multiplier. Also, the frictional pressure drop was compared to a few available correlations; The Lockhart-Martinelli correlation considerally overpredicted the frictional pressure drop data for mixture as well as pure components in the entire mass velocity ranges employed in the present study, while the Chisholm correlation underpredicted the present data. The Friedel correlation was found to satisfactorily correlate the frictional pressure drop data except for a low quality region.

Linking Clinical Events in Elderly to In-home Monitoring Sensor Data: A Brief Review and a Pilot Study on Predicting Pulse Pressure

  • Popescu, Mihail;Florea, Elena
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.180-199
    • /
    • 2008
  • Technology has had a tremendous impact on our daily lives. Recently, technology and its impact on aging has become an expanding field of inquiry. A major reason for this interest is that the use of technology can help older people who experience deteriorating health to live independently. In this paper we give a brief review of the in-home monitoring technologies for the elderly. In the pilot study, we analyze the possibility of employing the data generated by a continuous, unobtrusive nursing home monitoring system for predicting elevated(abnormal)pulse pressure(PP) in elderly(PP=systolic blood pressure-diastolic blood pressure). Our sensor data capture external information(behavioral) about the resident that is subsequently reflected in the predicted PP. By continuously predicting the possibility of elevated pulse pressure we may alert the nursing staff when some predefined threshold is exceeded. This approach may provide additional blood pressure monitoring for the elderly persons susceptible to blood pressure variations during the time between two nursing visits. We conducted a retrospective pilot study on two residents of the TigerPlace aging in place facility with age over 70, that had blood pressure measured between 100 and 300 times during a period of two years. The pilot study suggested that abnormal pulse pressure can be reasonably well estimated (an area under ROC curve of about 0.75) using apartment bed and motion sensors.

Analysis of the Plantar Pressure on the Flat and Slope Walking by Insole Type

  • Kim, Bu Gan;Lee, Joong Sook;Yang, Jeong Ok;Lee, Bom Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.3
    • /
    • pp.165-173
    • /
    • 2018
  • Objective: The purpose of this study is to provide biomechanical basis data for the analysis of the maximum vertical ground reaction force, the maximum plantar pressure, the average plantar pressure, and the contact area according to the type of the insole through the insole insertion type foot pressure gauge. Method: In the treadmill, the slope was set at 10%, the first type A was worn at a walking speed of 3.5 km / h, and then walking was carried out using B, C, and D types. Data from 20 boots with consistent walking were extracted and plantar pressure data were collected and analyzed. Results: Functional insole was more effective than conventional insole for maximum vertical ground reaction force, maximum plantar pressure, average plantar pressure, and contact area at 10% of treadmill ramps. Conclusion: In this study, D-type insole supports the cushion in the middle part and supports the heel cup with hardness in the hind part, so that it is the most effective insole by lowering the plantar pressure and dispersing it more widely.

Influential Factors for SMEs of Environmentally Friendly Management in Chinese Distribution Industry

  • CUI, Yuan;BAO, Youjian;CAI, Yunwei;KIM, Seung-Woon
    • Journal of Distribution Science
    • /
    • v.20 no.4
    • /
    • pp.65-75
    • /
    • 2022
  • Purpose: Environmental pollution problems have become more and more serious, how to effectively protect the environment has become a hot spot of concern to all sectors of society. The way to solve this problem is environmentally friendly management. However, theoretical perspectives and research frameworks of existing research on environmentally friendly management are still unclear. This study aims to examine how the CEO's beliefs for SMEs of Chinese distribution industry affect the environmentally friendly management based on institutional theory. Research design, data, and methodology: This paper collected data from 215 SMEs in China distribution industry and conducted a series of data analysis and hypothesis testing based on an institutional theory perspective using Amos and SPSS to verify the effects of regulatory pressure, normative pressure, and imitation pressure on firms' environmentally friendly management. Results: Through the analysis, this paper tests that normative pressure and imitative pressure have a positive effect on CEO's beliefs. However, regulatory pressure did not have a significant effect on beliefs of CEO. Meanwhile, the degree of CEO's beliefs has a positive effect on environmentally friendly management in Chinese distribution SMEs. Conclusions: Theoretical contributions, practical implications, and future research directions are discussed.

Risk Factors of Severity of Pressure Injuries in Acute University Hospital Inpatients (급성기 대학병원 입원환자의 욕창중증도의 영향요인)

  • Cho, Bo Kyung;Ko, Young;Kwak, Chanyeong
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.11
    • /
    • pp.98-106
    • /
    • 2020
  • This study was conducted to identify the factors influencing the severity of pressure injuries of patients with pressure injuries admitted to acute university hospital. This study was a secondary analysis on the data of the study conducted to identify the factors influencing the deterioration of pressure injuries during hospitalization. The data were collected by retrospectively examining the medical records of patients with pressure injuries who were 18 years of age or older and who were admitted to acute university hospital from May 2017 to November 2018. We used data from 472 patients with pressure injuries at admission for this secondary analysis. In order to identify the factor influencing of severe pressure injuries compare to superficial pressure injuries, we analyzed the data using logistic regression analysis. As a result of the study, gender, body temperature, and patient's movement were identified as factors affecting severe pressure injuries. Therefore, special care is necessary to increased the number of position change for inpatients with pressure injuries, especially for patients with decreased mobility.

Pressure drop of R-22 and R-407C during condensation in horizontal smooth tubes (냉매 R-22, R-407C의 수평평활관내 응축압력강하에 관한 연구)

  • 노건상;오후규;권옥배
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.4
    • /
    • pp.70-80
    • /
    • 1996
  • Experimental results for forced convection condensation of R-22 and R-407C inside 7.5mm ID and 4000mm length of horizontal tubes are presented. The experimental data covered total flow rate from 114.3 to 267.1kg/($m^2$.s) and quality from 0 to 1. The vapor temperature and pressure drop along the tube were measured. The pressure drop for R-407C increased with flow rate similar to that of R-22. The experimental data compared with the available perdictions for pressure drop. Based on the data a prediction method was presented for the calculation of pressure drop of R-22 alternative refrigerants.

  • PDF