• Title/Summary/Keyword: pressure comfort

Search Result 229, Processing Time 0.021 seconds

A Study on the Transition & Expectation through Survey for Existing Building and Engineer's Opinion (기존 사무소 건물 및 설비전문가 조사를 통한 설비시스템의 변화와 전망에 대한 연구)

  • Lee, Gwan-Ho;Kim, Nam-Gyu;Park, Jin-Chul;Rhee, Eon-Ku
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.2
    • /
    • pp.63-69
    • /
    • 2005
  • This study is the survey of a transition procedure of building services systems(heat source, HVAC, water supply) through the survey of existing office buildings, building design documents. The preference & major consideration of system selection is the engineer's opinions. The results of this survey can be used in selection of building services system design. In this survey, "Hot & cold water generator system" and "single duct CAV+FCU system", "Elevated water tank system" are selected. The most important consideration in system selection is the energy saving in heat source system, and comfort in HVAC system, and water pressure in water supply system. They prefer "steam boiler+absorption chiller system" for heat source system, "steam boiler+ice thermal storage system", "hot & cold water generator system", "district heating+absorption chiller system" : "single duct CAV+FCU system" and "single duct VAV+convector system" for HVAC system: and "booster pump system" for water supply system.

Adaptive Compensation Control of Vehicle Automatic Transmissions for Smooth Shift Transients Based on Intelligent Supervisor

  • Kim, Deok-Ho;Han, Jin-O;Sin, Byeong-Gwan;Lee, Gyu-Il
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.11
    • /
    • pp.1472-1481
    • /
    • 2001
  • In this paper, an advanced shift controller that supervises the shift transients with adaptive compensation is presented. Modern shift control systems for vehicle automatic transmission are designe d to provide smooth transients for passengers' comfort and better component durability. In the conventional methods, lots of testing and calibration works have been done to tune gains of the controller, but it does not assure optimum shift quality at all times owing to system variations often caused by uncertainties in shifting hydraulic systems and external disturbances. In the proposed control scheme, an adaptive compensation controller with intelligent supervisor is implemented to achieve improved shift quality over the system variations. The control input pattern which generates clutch pressure commands in hydraulic actuating systems, is updated through a learning process to adjust for each subsequent shift based on continuous monitoring of shifting performance and environmental changes. The proposed algorithm is implemented and evaluated on the experimental test setup. Results from the experimental studies for several operation modes show both improved performance and adaptability of the proposed shift controller to uncertain changes of the shifting environment in vehicle power transmission systems.

  • PDF

Developing an Artificial Intelligence Algorithm to Predict the Timing of Dialysis Vascular Surgery (투석혈관 수술시기 예측을 위한 인공지능 알고리즘 개발)

  • Kim Dohyoung;Kim Hyunsuk;Lee Sunpyo;Oh Injong;Park Seungbum
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.19 no.4
    • /
    • pp.97-115
    • /
    • 2023
  • In South Korea, chronic kidney disease(CKD) impacts around 4.6 million adults, leading to a high reliance on hemodialysis. For effective dialysis, vascular access is crucial, with decisions about vascular surgeries often made during dialysis sessions. Anticipating these needs could improve dialysis quality and patient comfort. This study investigates the use of Artificial Intelligence(AI) to predict the timing of surgeries for dialysis vessels, an area not extensively researched. We've developed an AI algorithm using predictive maintenance methods, transitioning from machine learning to a more advanced deep learning approach with Long Short-Term Memory(LSTM) models. The algorithm processes variables such as venous pressure, blood flow, and patient age, demonstrating high effectiveness with metrics exceeding 0.91. By shortening the data collection intervals, a more refined model can be obtained. Implementing this AI in clinical practice could notably enhance patient experience and the quality of medical services in dialysis, marking a significant advancement in the treatment of CKD.

Biomechanical Evaluation of Trekking Shoes using 3D Bootie Method as Mimics Barefoot Form (맨발 구조를 모사한 3D Bootie 공법을 적용시킨 트레킹화의 생체역학적 특성 평가)

  • Yoo, Chan-Il;Jeon, Keun-Hwan;Won, Yonggwan;Kim, Jung-Ja
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4689-4696
    • /
    • 2015
  • The purpose of this study was to evaluate biomechanical characteristics of trekking shoes using 3D Bootie method as mimics barefoot form of F Co. that provides the best comfort and plantar pressure dispersion. The control group is normal trekking shoes of M Co. and K Co.. 13 healthy males measured the foot pressure, EMG and GRF. Collected data was analyzed using One-way ANOVA in order to investigate the effects of each trekking shoes. The results are as follows: Trekking shoe of F Co. was significantly wider in contact area than others at MF and significantly lower in maximum force, peak pressure than others at RF. In the case of muscle activity, acted in the same way as the effect of barefoot walking. In the case of GRF, effectively absorbed the impact force, so it is possible to efficient walking. As a result of the analysis, trekking shoe using of 3D Bootie method of F Co. can be efficient walking by reducing the load of foot during walking.

A Numerical Analysis of the Pressure Drop according to the Shape of TiO2 Photocatalyst-coated Module in a HVAC Duct (HVAC 덕트 내에 설치된 광촉매코팅 모듈의 형상이 압력강하에 미치는 영향)

  • Hwang, Kwang-Il;Koo, Jae-Hyoek;Kim, Da-Hye;Lee, Hyun-In;Choi, Young-Guk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.8
    • /
    • pp.1055-1062
    • /
    • 2011
  • The purpose of this study is to develop the shape of photocatalyst-coated module for improve the IAQ, which is installed at inside of ductwork and detachable. Including 3 column types(square, circle, diamond) and 2 fin types(diamond and square), totally 5 types are previously declared for numerical analysis and comparison, 5 types are. As the results of numerical analysis, almost the velocity varied at the range of ${\pm}0.3m$ from the module, except the Type A-3(diamond column type) which is affected to ${\pm}0.4m$ range and shows the biggest velocity differences. Among the 5 types, the diamond fin type(Type B-1) is analyzed as the most stable in velocity. And the results of local pressure drop show that the difference of pressure coefficient of Type B-1 is computed as 0.59, and that of Type A-3 is 2.44. Meanwhile, from the effect analysis of the number of module, the flow conflict happens and the pressure difference between before and after the module increases if there are over 3 modules inserted.

Plantar foot pressure analysis during golf swing motion using plantar foot pressure measurement system (족저압력분포 측정장비를 이용한 골프 스윙시 족저압 분석)

  • Lee, Dong-Ki;Lee, Joong-Sook;Lee, Bom-Jin;Lee, Hun-Sik;Kim, Young-Jae;Park, Seung-Bum;Joo, Jong-Peel
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.1
    • /
    • pp.75-89
    • /
    • 2005
  • D. K. LEE, J. S. LEE, B. J. LEE, H. S. LEE, Y. J. KIM, S. B. PARK, J. P. JOO. Plantar foot pressure analysis during golf swing motion using plantar foot pressure measurement system. Korean Journal of Sport Biomechanics, Vol. 15, No. 1, pp. 75-89, 2005. In this study, weight carrying pattern analysis and comparison method of four foot region were suggested. We used three types of club(driver, iron7, pitching wedge). This analysis method can compare between top class golfer and beginner. And the comparison data can be used to correct the swing pose of trainee. If motion analysis system, which can measure the swing speed and instantaneous acceleration at the point of hitting a ball, is combined with this plantar foot force analysis method, new design development of golf shoes to increase comfort and ball flight distance will be available. 1. Address acting, forces concentrated in rare foot regions and lateral foot of right foot. Back swing top acting, relatively high force occurred in medial forefoot region of left foot and forefoot region of right foot. Impact acting, high force value observed in the lateral rarefoot region of left foot and medial forefoot region of right foot. Finish acting, force concentration observed on the lateral region and rarefoot region of left foot. 2. Forces were increased in address of right foot with clubs length increased. All clubs, back swing top acting, high force value observed in the lateral forefoot region of right foot. All clubs, in impact, high force value observed in the lateral rarefoot region of left foot and medial forefoot region of right foot. Finish acting, force concentration observed on the rarefoot region in driver and lateral foot region in iron on left foot. 3. Right foot forces distribution were increased in address, back swing top and left foot force distribution were increased in impact, finnish

A Study on the Comfort and Skin Temperature on the Clothing Environment in the Taegu City during Years -Concentrated on indoor uniforms- (섬유·패션 산업 DB 구축을 위한 대구지역의 연간 피복환경내의 피부온과 쾌적성 -실내 제복을 중심으로-)

  • Ryo, Duck-Hwan;Lee, Uk-Ja;Kim, Seong-Jin;Song, Min-Kyo;Cho, Ji-Hyun;Jung, Meung-Sun
    • Fashion & Textile Research Journal
    • /
    • v.1 no.4
    • /
    • pp.376-386
    • /
    • 1999
  • The purpose of this study was to determine the physiological responses and the Subjective sensations of the human subjects when 10 human subjects(5 males and 5 females) were tested with selected ensembles, including the uniforms of students, industrial and bank workers. For the study, garment material and design were selected, which was mostly used in Taegu area by the survey. Thermal manikin and the human subject tests were performed. The results were as follows: 1. There was no significant difference among skin temperature of head by season and among that of breast and back by all variables, however, there was a significant difference among that of belly by gender and that of thigh and shank by season. In addition, there was no significant difference among rectal temperature by gender and season, but there was a significant difference by uniform. 2. Mean skin temperature of male subjects was significantly higher than that of female subjects. Specially in lower environmental condition, the difference got larger. 3. There was a significant difference among purse rate of subjects by uniform, but there was no significant difference among those by gender and season. There were no significant difference among maximum and minimum blood pressure by gender, uniform, and season. 4. There was a significant difference in temperature of chest among gender and uniform, and there was no significant difference in temperature of back by season. In addition, There was a significant difference in humidity of back by uniform and season but there were no significant difference in that by gender. 5. There was a significant difference in humidity sensation by gender, comfort sensation by uniform and season, but there was no significant difference thermal sensation by uniform and season. 6. For the result of regression analysis, we got the regression equations as follows: Clo=1.810 Thickness+0.525, Clo=0.475 weight+0.863.

  • PDF

Effect of Wear Training on Temperature Adaptability of the Obese Children (비만아동의 온도적응성에 대한 착의훈련 효과)

  • Jeong, Woon-Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.3 s.151
    • /
    • pp.407-411
    • /
    • 2006
  • This study was carried out to investigate the physiological responses of obese children after a short-term wear training and education. A ten-week program was conducted on thirteen obese elementary school children of six boys and seven girls in the 4th to the 6th grade. During the program, the children were instructed to measure daily ambient temperature and weight of their clothing. Physiological responses of the sedentary children in 100$\%$ cotton short sleeved t-shirt (0.13clo) and T/C short pants(0.09clo) were observed in the climatic chamber of 23.0$\pm$0.5$^{circ}C$ and 50$\pm$5$\%$RH before and after program. During the experiment, internal ear temperature ($T_{ear}$), seven site skin temperatures, systolic blood pressure, diastolic blood pressure, heart rate, and subjective responses of thermal comfort and thermal sensation were measured every 5minutes. Mean skin temperature($T_{sk}$) and mean arterial pressure(MAP) were calculated. Obtained data are statistically analyzed and main results are as follows. There was highly significant correlation between the ambient temperature and the total clothing weight. $T_{ear}$ and MAP were reduced in the post-program compared to the pre-program. The obese girls felt slightly warmer than the obese boys and the girls were likely to prefer lower ambient temperature in the post-program than the pre-program. It was concluded that the 10 week wear training is apt to be more applicable to the obese girls than the obese boys. However, a more comprehensive study including. diverse measurements of deep body temperature with a long-term training would be needed to clarify the improvement of temperature adaptability in the obese children.

Biomechanical Analysis of Different Thoracolumbar Orthosis Designs using Finite Element Method (유한요소 해석을 이용한 정형용 흉·요추 보조기의 형태에 따른 생체역학적 분석)

  • Kim, Y.H.;Jun, S.C.;Jung, D.Y.;Lee, S.J.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.6 no.1
    • /
    • pp.45-50
    • /
    • 2012
  • Thoracolumbar orthosis has been used for the rehabilitation of the patients with senile kyphosis. Recently, a number of different thoracolumbar orthosis designs have been introduced but its biomechanical effectiveness still remain unknown. In this study, we compared the pressure distribution on the surface of the trunk and stresses on the orthosis in relation to changes in connecting frame designs (Type 1, one-connecting frame type; Type 2, two-connecting frame type; Type 3, all-in-one type) using finite element (FE) models under different motions of the trunk. The results showed that Type 3 distributed the pressure on the trunk most evenly followed by Type 2 and Type 1 and the difference between Type 1 and Type 2 was negligible. ROM was limited most effectively by Type 3 ($8.5{\sim}9.4^{\circ}$), followed by Type 2 ($11.3{\sim}13.9^{\circ}$) and Type 1 ($12.1{\sim}15.4^{\circ}$). The ratio between the peak von Mises stress and yield strength of each material remained less than 20% regardless of orthosis type indicating low likelihood of component failure. In conclusion, our study found that all-in-one type of orthosis was the most effective design for the conservative treatment of spinal deformity in terms of function and comfort.

  • PDF

Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery (개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구)

  • Yu Mi;Kwon Eun-Ok;Choi Yun-Kyoung;Kang Hyun-Ju;Oh Se-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF