• Title/Summary/Keyword: prepectoral breast

Search Result 14, Processing Time 0.018 seconds

Breast animation deformity

  • Dyrberg, Diana Lydia;Bille, Camilla;Gunnarsson, Gudjon Leifur;Frandsen, Tove Faber;Salzberg, C. Andrew;Sorensen, Jens Ahm;Thomsen, Jorn Bo
    • Archives of Plastic Surgery
    • /
    • v.46 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Breast animation deformity (BAD) has been reported to occur after submuscular implant placement following breast augmentation and immediate breast reconstruction. Despite its apparent impact on patients' quality of life, BAD has only recently become a topic of general concern. Its incidence and etiology have yet to be established. The aim of this systematic review was to identify papers that clearly defined and classified BAD and described how the degree of animation was assessed. We performed a search in PubMed and Embase. Studies meeting the inclusion criteria that described BAD after implant-based breast augmentation or immediate breast reconstruction were included. After screening 866 publications, four studies were included: three describing BAD after breast augmentation and one describing BAD after immediate breast reconstruction. The median percentage of patients with some degree of BAD was 58%. The highest percentages were found in patients operated on using the Regnault technique or the dual-plane technique (73%-78%). The lowest percentages were found following the dual-plane muscle-splitting technique (30%) and the triple-plane technique (33%). We found no studies meeting the inclusion criteria that analyzed BAD after prepectoral implant placement. This review of the current literature suggests that the degree of BAD is proportional to the degree of muscle involvement. Evidence is scarce, and the phenomenon seems to be underreported. Future comparative studies are warranted.

Single-port robot-assisted prosthetic breast reconstruction with the da Vinci SP Surgical System: first clinical report

  • Joo, Oh Young;Song, Seung Yong;Park, Hyung Seok;Roh, Tai Suk
    • Archives of Plastic Surgery
    • /
    • v.48 no.2
    • /
    • pp.194-198
    • /
    • 2021
  • Robot-assisted nipple-sparing mastectomy with immediate reconstruction is currently performed in an attempt to seek smaller and indistinct incisions. Robotic surgery system has been evolving under the concept of minimal invasive technique which is a recent trend in surgery. One of the latest version is the da Vinci SP Surgical System (Intuitive Surgical). In this report, we will share our experiences. Two patients underwent robot-assisted nipple-sparing mastectomy, each followed by immediate robot-assisted expander insertion and prepectoral direct-to-implant breast reconstruction, respectively. There was no open conversion or major postoperative complication. One patient experienced mild infection, which was resolved by intravenous antibiotic treatment. Simple docking process, multi-joint instruments, and thirdarm functionality are among the new surgical system's advantages. The present cases suggest that robot-assisted nipple-sparing mastectomy with immediate reconstruction using the da Vinci SP Surgical System is feasible and safe. The promising features and potential application of da Vinci SP in breast reconstruction need further study.

Effect of Perioperative Prophylactic Intravenous Antibiotic Use in Immediate Implant-Based Breast Reconstruction: A Retrospective Matched Cohort Study

  • Seok Kyung In;Seok Won Park;Yujin Myung
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.36-41
    • /
    • 2024
  • Background Among breast reconstruction methods, implant-based breast reconstruction has become the mainstream. However, periprosthetic infection is still an unresolved problem. Although published articles have revealed that limited use of antibiotics is sufficient to reduce infection rates, the number of surgeons still preferring elongated usage of antibiotics is not less. The aim of our study is to validate the appropriate duration of antibiotic use to reduce infection rate after implant-based breast reconstruction. Methods A retrospective study reviewed medical record of 235 patients (274 implants for reconstruction) who underwent prepectoral direct to implant breast reconstruction using acellular dermal matrix wrapping technique. Infection rates were analyzed for the patients administered postoperative prophylactic antibiotics until drain removal and those who received only perioperative prophylactic antibiotics for 24 hours. Results Of the 274 implants, 98 who were administered prophylactic antibiotics until drain removal had an infection rate of 3.06% (three implants) and 176 who received prophylactic antibiotics no longer than 24 hours postoperatively had an infection rate of 4.49% (eight implants). A total of 11 patients diagnosed with postoperative infection clinically, 8 were salvaged by antibiotic treatment, and 3 had implant removal and replacement with autologous flap. Postoperative antibiotic prophylaxis duration had no statistically significant effects in the risk of infection (p = 0.549). Conclusion The duration of prophylactic antibiotics after surgery was not related to infection risk. Further study with a large number of patients, randomized control study, and route of antibiotics is needed.

Smooth versus Textured Tissue Expanders: Comparison of Outcomes and Complications in 536 Implants

  • Omar Allam;Jacob Dinis;Mariana N. Almeida;Alexandra Junn;Mohammad Ali Mozaffari;Rema Shah;Lauren Chong;Olamide Olawoyin;Sumarth Mehta;Kitae Eric Park;Tomer Avraham;Michael Alperovich
    • Archives of Plastic Surgery
    • /
    • v.51 no.1
    • /
    • pp.42-51
    • /
    • 2024
  • Background Increasing concerns regarding the safety of textured surface implants have resulted in surgeons transitioning from textured tissue expanders (TEs) to smooth TEs. Given this change has only recently occurred, this study evaluated outcomes between smooth and textured TEs. Methods Women who underwent two-stage breast reconstruction using TEs from 2013 to 2022 were included. TE-specific variables, perioperative information, pain scores, and complications were collected. Chi-squared, t-test, and linear regression analyses were performed. Results A total of 320 patients received a total of 384 textured and 152 smooth TEs. Note that 216 patients received bilateral reconstruction. TEs were removed in 9 cases. No significant differences existed between groups regarding comorbidities. Smooth TEs had a higher proportion of prepectoral placement (p < 0.001). Smooth TEs had less fills (3±1 vs. 4±2, p < 0.001), shorter expansion periods (60±44 vs. 90±77 days, p < 0.001), smaller expander fill volumes (390±168 vs. 478±177 mL, p < 0.001), and shorter time to exchange (80±43 vs. 104±39 days, p < 0.001). Complication rates between textured and smooth TEs were comparable. Smooth TE had a greater proportion of TE replacements (p = 0.030). On regression analysis, pain scores were more closely associated with age (p = 0.018) and TE texture (p = 0.046). Additional procedures at time of TE exchange (p < 0.001) and textured TE (p = 0.017) led to longer operative times. Conclusion As many surgeons have transitioned away from textured implants, our study shows that smooth TEs have similar outcomes to the textured alternatives.