• Title/Summary/Keyword: preparation method

Search Result 4,090, Processing Time 0.033 seconds

TEM Specimen Preparation Method of Gibbsite Powder for Quantitative Structure Analysis (정량 구조 분석을 위한 Gibbsite 분말의 TEM 시편 준비법)

  • Kim, Young-Min;Jeung, Jong-Man;Lee, Su-Jeong;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.32 no.4
    • /
    • pp.311-317
    • /
    • 2002
  • There is great requirement on the TEM specimen preparation method with particle size selectivity as a prerequisite for the quantitative structure analysis on the materials such as gibbsite powder, which generally forms a large agglomerate and shows a variation of transition process depending on their sizes. In this experiment, we made an attempt to give a methodology for the TEM specimen preparation of powder with the size selectivity. After mixing 1 wt% gibbsite powder with ethanol solvent, gibbsite suspension was prepared by application of ball-milling and ultrasonification with addition of 0.25 vol% dispersion agent, Darvan C, which was diluted into distilled water by the ratio 1:19. Appling the static sedimentation method to gibbsite suspension after estimation of the sedimentation time by the measurement of accumulative concentration variation, we acquired TEM specimens with well-dispersed and size selected gibbsite particles in nm scale. Overall picture of each sample was taken by SEM and morphology of each dispersed particle was imaged by TEM. Raw and processed gibbsite powders were also examined by XRD to investigate whether they were suffered from phase change during the process or not.

THE EFFECT OF THE METHOD OF CANAL PREPARATION ON THE QUALITY OF CANAL OBTURATION (근관형성방법(根管形成方法)이 근관폐납성(根管閉鑞性)에 미치는 영향(影響)에 관(關)한 연구(硏究))

  • Lim, Sung-Sam
    • Restorative Dentistry and Endodontics
    • /
    • v.8 no.1
    • /
    • pp.161-166
    • /
    • 1982
  • The purpose of this study was to examine the influence of canal preparation on the property of apical seal. Seventy canals from extracted human maxillary and mandibular teeth were randomly selected and divided into two groups: conventional group and step-back group. Thirty five canals in one group were enlarged with a, conventional preparation method and thirty five canals in the other group were instrumented in a step-back method with K-file. After instrumentation sixty canals were obturated by lateral condensation of gutta percha and zinc oxide eugenol cement, and five canals in each group were not filled and used as control. All the specimens were immersed in 2% methylene blue dye solution and the depth of dye penetration into the canals were observed by macroscope at the intervals of 1 day, 2 days, and 7 days. The following results were obtained. 1. All the canals experimented showed varying degrees of dye penetration. 2. There was no significant difference between conventional method and step-back method in the depth of dye penetration and the degree of dye penetration tended to increase with time passage in both groups. 3, In conventional preparation group the mean dye penetration was 3.6mm at 1 day, 4.8mm at 2 days. and 6.5mm at 7 days. 4. In step-back prepareation group, the specimens exposed to the dye for 1 day showed mean dye penetration of 4.1mm, and the specimens immersed in the dye for 2 days and 7 days revealed mean dye penetration of 4.6mm and 6.2mm respectively.

  • PDF

A Study on Preparation of Nano size cement particle by Mechanical method (기계적 방법에 따른 나노 시멘트 입자의 제조에 관한 연구)

  • Jo Byung-Wan;Park Jong-Bin
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.216-219
    • /
    • 2004
  • Due to the recent amazing achievements in nano technology. preparation of cement nano particles by mechanical method are examined to improve their properties. The experimental results show that the particle size after 3 hr milling were about 500nm. The SEM photographs of specimens also reveal that average sizes of cement particles are gradually decreased by milling time. And in the TG/DSC, influence of the alcohol is showed strongly. The value of TG of the crushed cement was larger than that of the non-crushed cement. That is also judged to be cause the alcohol.

  • PDF

Surface Modification Studies by Atomic Force Microscopy for Ar-Plasma Treated Polyethylene

  • Seo, Eun-Deock
    • Macromolecular Research
    • /
    • v.10 no.5
    • /
    • pp.291-295
    • /
    • 2002
  • Atomic force microscopy(AFM) was used to study the polyethylene(PE) surfaces grafted and immobilized with acrylic acid by Ar plasma treatment. The topographical images and parameters including RMS roughness and Rp-v value provided an appropriate means to characterize the surfaces. The plasma grafting and immobilization method were a useful tool for the preparation of surfaces with carboxyl group. However, the plasma immobilization method turned out to have a limitation to use as a means of preparation of PE surface with specific functionalities, due to ablation effect during the Ar plasma treatment process.

Sample Preparation for Microstructural Characterization of Ni-Yttria-Stabilized Zirconia Anodes

  • Sim, Soo-Man
    • Journal of the Korean Ceramic Society
    • /
    • v.55 no.4
    • /
    • pp.376-380
    • /
    • 2018
  • Microstructural characterization of Ni-yttria-stabilized zirconia (YSZ) anodes using secondary electron images has been limited by a lack of contrast between Ni and YSZ phases. This paper reports a sample preparation method for obtaining secondary electron images that allow the detection of Ni, YSZ, and pore phases together. Ni-YSZ anode samples were obtained by reducing NiO-YSZ samples prepared by using the mixed oxide method. Colloidal silica polishing and electrolytic etching were performed on the Ni-YSZ samples. The morphological change of the sample surface after each polishing process is examined.

Preparation for Old Age Life of Dental Hygienists (치과위생사의 노후생활 준비)

  • Kim, Min-Young;Kim, Sun-Ju;Kim, Ji-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.8
    • /
    • pp.250-256
    • /
    • 2014
  • This study was carried out in order to seek social support direction by allowing them to recognize necessity of preparing for their stably old age life and by inquiring into the preparation for old age life targeting dental hygienists who work at dental clinics. It sent questionnaire by post to dental hygienists of 1,560 dental clinics, which were sampled with a stratified sampling method, and then conducted a cross-sectional study based on self-administration. As a result of a problem of being worried in old age life, the ratio with the response as saying of being 'economy' was indicated to be the highest. The ratio of financial preparation for old age was shown to be high with 84.3%. Its method was the highest in 'fixed deposit and installment savings' with 62.6%. The satisfaction with financial preparation for old age stood at averagely 2.60, thereby having shown to be dissatisfied. It was shown to be low with 2.97 in the mean score of physical preparation for old age life, 3.59 in emotional preparation, and 2.56 in preparation for leisure. In conclusion, the satisfaction with financial preparation for old age life in our country's dental hygienists was low. Even the physical, emotional, and leisure-based preparations were shown to be low. Hence, it is considered to be likely needed to be planned preparation for old age life from the 30s. Also, for this, Korean Dental Hygienists Association needs to positively develop several kinds of programs such as education, policy and system for old age life following these people's retirement.

COMPARISON OF CANAL SHAPING METHODS WITH GTTM ROTARY FILE AND CONDENSATION METHODS (GT rotary file을 이용한 근관성형법과 충전방법의 비교)

  • Kang, Yu-Mi;Jin, Jeong-Hee;Yu, Mi-Kyung;Lee, Se-Joon;Lee, Kwang-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.521-529
    • /
    • 2002
  • The purpose of this study was to compare the shaping time of two shaping methods and the leakage of three different obturation techniques. Ninty three canaled human molar teeth were used, which were randomly divided into two groups of forty teeth each and ten control teeth. After working length determination, the one group was prepared crown-down technique using rotary root canal instruments of GT rotary files .12/20, .10/20, .08/20 and .06/20 taper(Maillefer Instrument SA. Switzerland). The other group was instrumented with Gates Glidden burs(#1, #2, and #3) to coronal preparation and GT rotary files .08/20 and .06/30 taper to apical preparation. Shaping time was measured. After root canals were instrumented, they were divided to three subgroups and obturated as follows : Subgroup 1, obturated with single cone method Subgroup 2, obturated with lateral condensation : Subgroup 3, obturated with continuous wave technique. Three subgroups were obturated using non-standardized gutta-percha cone(Diadent, Korea, .06 or .08 taper) and AH-26(Dentsply DeTrey, Germany) as a root canal cement. Ten unobturated teeth served as positive and negative controls. After immersion in 2% methylene blue solution for 1 month, the teeth were washed during 24h. The teeth were demineralized in 10% nitric acid and dehydrated by immersion in 80, 90 and 100% ethyl alcohol. The teeth were finally cleared and stored in 100% methylsalicylate, and apical dye penetration was evaluated under stereomicroscope(Leica M420, LC, U.S.A)at $\times$8.75 magnification. Liner measurement of dye penetration was assessed with the use of digitalized image analysing system (analySIS, GmbH, Germany) The data were analysed statistically using independent T-test and Two-way ANOVA and Tukey test. The result were as follows 1. In canal prepared with GT$^{TM}$ rotary file, shaphing time taked more than the group of using Gates Glidden drill to coronal preparation without statistical significance (p>0.05) 2. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files showed significantly more apical leakage than those of lateral condensation and continuous wave technique regardless of shaping method (p<0.05). 3 The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed significantly more apical leakage than those of continuous wave technique regardless of shaping method (p<0.05). 4. Regardless of shaping method, The group of continuous wave obturation showed less apical leakage than those of lateral condensation without statistical significance (p>0.05). 5. The group of single cone obturation using canal preparation of GT$^{TM}$ rotary files and Gates Glidden drill showed more apical leakage than the group of lateral condensation using same shaping method with-out statistical significance (p>0.05).

Establishment of Sample Preparation Method for PCR Detection of Clostridium perfringens from Agricultural Products (PCR 법을 이용한 농산물 중 Clostridium perfringens 검출을 위한 전처리법 확립)

  • Choi, Song-Yi;Seo, Min-Kyoung;Yoon, Jae-Hyun;Rajalingam, Nagendran;Hwang, Injun;Kim, Se-Ri
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.93-99
    • /
    • 2021
  • This study was undertaken to compare the efficacy of different sample preparation (stomaching, pulsifying, and sonication) and DNA extraction methods (boiling and commercial kit) for detection of enterotoxin-producing Clostridium perfringens from produce by polymerase chain reaction (PCR). Each produce type was inoculated at concentrations of 102, 103, 104, 105, 106, and 107 spores/g. Produce inoculated with spores was treated with three sample preparation methods, and DNA was extracted by boiling method and a commercial kit, followed by PCR. The detection limit of stomached samples was lower than that of pummeled and sonicated samples by 10-100 times. Moreover, the DNA extraction efficiency of the commercial kit was found to be superior to that of boiling. In particular, the PCR efficiency of cherry tomato and perilla leaf samples was greatly affected by sample preparation and DNA extraction method. These data suggest that DNA extraction with a commercial kit after pulsification is an optimum sample preparation method for detection of C. perfringens by PCR.

A Study of Simple α Source Preparation Using a Micro-coprecipitation Method

  • Lee, Myung Ho;Park, Tae-Hong;Song, Byung Chul;Park, Jong Ho;Song, Kyuseok
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3745-3748
    • /
    • 2012
  • This study presents a rapid and simple ${\alpha}$ source preparation method for a radioactive waste sample. The recovery of $^{239}Pu$, $^{232}U$ and $^{243}Am$ using a micro-coprecipitation method was over 95%. The ${\alpha}$-peak resolution of Pu and Am isotopes through the micro-coprecipitation method is enough to discriminate the Pu and Am isotopes from other Pu and Am isotopes. The determination of the Pu and Am isotopes using the micro-coprecipitation method was applied to the radioactive waste sample, so that the activity concentrations of the Pu and Am isotopes using the micro-coprecipitation method in the radioactive waste sample were similar to those using the electrodeposition method.

Method for Simultaneous Determination of Cyanotoxins in Water by LC-MS/MS (액체크로마토그래프/질량분석기를 이용한 수중 남조독소물질 동시분석법)

  • Kim, Jeong-Hee;Yun, Mi-Ae;Kim, Hak-Chul
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.597-605
    • /
    • 2009
  • Algae bloom occurred in reservoir in summer can cause taste and odor in water and disturb the flocculation and sedimentation processes in water treatment plant and cause sand filter plugging. It was also reported that microcystins, anatoxin and saxitoxin released from cyanobacteria had acute toxic effects on liver and nervous system. For these reasons, many advanced countries inclusive of WHO set the guideline for these toxins and cyanotoxins have been managed with regular monitoring in Korea as well. However, complex sample preparation steps such as a solid phase extraction (SPE) and derivatization are required with an existing analysis method with HPLC. We needed to improve an analysis method for low extraction efficiency and long sample preparation time. In this study, we have established a new LC/MS/MS method which can simultaneously determine 6 cyanotoxins (Microcystins-LR, Microcystins-RR, Microcystins-YR, Anatoxin-a, Saxitoxin, Neosaxitoxin) with only simple filtration step. When $75{\mu}L$ filterated sample was injected onto the LC-MS/MS, the recovery ranged from 86% to 112% and the MDL was $0.025{\sim}0.581{\mu}g/L$. We can make the MDL be lower than the guideline ($1{\sim}3{\mu}g/L$) of advanced countries with simple preparation.