• Title/Summary/Keyword: premolar

Search Result 985, Processing Time 0.021 seconds

Consideration of root position in virtual tooth setup for extraction treatment: A comparative study of simulated and actual treatment results

  • Mirinae Park;Veerasathpurush Allareddy;Phimon Atsawasuwan;Min Kyeong Lee;Kyungmin Clara Lee
    • The korean journal of orthodontics
    • /
    • v.53 no.1
    • /
    • pp.26-34
    • /
    • 2023
  • Objective: The purpose of the present study was to compare the root positions in virtual tooth setups using only crowns in a simulated treatment with those achieved in the actual treatment. Methods: Pre- and post-treatment intraoral and corresponding cone beam computed tomography (CBCT) scans were obtained from 15 patients who underwent orthodontic treatment with premolar extraction. A conventional virtual tooth setup was used for the treatment simulation. Pre- and post-treatment three-dimensional digital tooth models were fabricated by integrating the patients' intraoral and CBCT scans. The simulated root positions in the virtual setup were obtained by merging the crown in the virtual setup and root in the pre-treatment tooth model. The root positions of the simulated and actual post-treatment tooth models were compared. Results: Differences in root positions between the simulated and actual models were > 1 mm in all teeth, and statistically significant differences were observed (p < 0.05), except for the maxillary lateral incisors. The differences in the inter-root angulation were > 1° in all teeth, and statistically significant differences were observed in the maxillary and mandibular canines. Conclusions: The virtual tooth setup using only crown data showed errors over the clinical limits. The clinical application of a virtual setup using crowns and roots is necessary for accurate and precise treatment simulation, particularly in extraction treatment.

Push-out bond strength and intratubular biomineralization of a hydraulic root-end filling material premixed with dimethyl sulfoxide as a vehicle

  • Ju-Ha Park;Hee-Jin Kim;Kwang-Won Lee;Mi-Kyung Yu;Kyung-San Min
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.8.1-8.8
    • /
    • 2023
  • Objectives: This study was designed to evaluate the parameters of bonding performance to root dentin, including push-out bond strength and dentinal tubular biomineralization, of a hydraulic bioceramic root-end filling material premixed with dimethyl sulfoxide (Endocem MTA Premixed) in comparison to a conventional powder-liquid-type cement (ProRoot MTA). Materials and Methods: The root canal of a single-rooted premolar was filled with either ProRoot MTA or Endocem MTA Premixed (n = 15). A slice of dentin was obtained from each root. Using the sliced specimen, the push-out bond strength was measured, and the failure pattern was observed under a stereomicroscope. The apical segment was divided into halves; the split surface was observed under a scanning electron microscope, and intratubular biomineralization was examined by observing the precipitates formed in the dentinal tubule. Then, the chemical characteristics of the precipitates were evaluated with energy-dispersive X-ray spectroscopic (EDS) analysis. The data were analyzed using the Student's t-test followed by the Mann-Whitney U test (p < 0.05). Results: No significant difference was found between the 2 tested groups in push-out bond strength, and cohesive failure was the predominant failure type. In both groups, flake-shaped precipitates were observed along dentinal tubules. The EDS analysis indicated that the mass percentage of calcium and phosphorus in the precipitate was similar to that found in hydroxyapatite. Conclusions: Regarding bonding to root dentin, Endocem MTA Premixed may have potential for use as an acceptable root-end filling material.

Do platelet concentrates accelerate orthodontic tooth movement?: a systematic review

  • Sergio Herrero-Llorente;Angel-Orion Salgado-Peralvo;Jan G.J.H. Schols
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.1
    • /
    • pp.2-19
    • /
    • 2023
  • Purpose: Surgical techniques in orthodontics have received widespread attention in recent years. Meanwhile, biomaterials with high molecular content have been introduced, such as platelet concentrates (PCs), which may accelerate orthodontic tooth movement (OTM) and reduce periodontal damage. The present systematic review aimed to answer the following PICO question: "In patients in whom orthodontic surgical techniques are performed (P), what is the effectiveness of using PCs over the surgical site (I) when compared to not placing PCs (C) to achieve faster tooth movement (O)?" Methods: A search was performed in 6 databases. The criteria employed were those described in the Preferred Reporting Items for Systematic Reviews and Meta-Analyses declaration. The present review included studies with a control group that provided information about the influence of PCs on the rate of OTM. Results: The electronic search identified 10 studies that met the established criteria. Conclusions: The included studies were very diverse, making it difficult to draw convincing conclusions. However, a tendency was observed for OTM to be accelerated when PCs were used as an adjuvant for canine distalization after premolar extraction when distalization was started in the same session. Likewise, studies seem to indicate an association between PC injection and the amount of canine retraction. However, it is not possible to affirm that the use of PCs in corticotomy shortens the overall treatment time, as this question has not been studied adequately.

Shape and anatomical relationship of the mental foramen to the mandibular premolars in an Indian sub-population: a retrospective CBCT analysis

  • Komal Sheth;Kulvinder Singh Banga;Ajinkya M. Pawar;James L. Gutmann;Hyeon-Cheol Kim
    • Restorative Dentistry and Endodontics
    • /
    • v.47 no.1
    • /
    • pp.1.1-1.13
    • /
    • 2022
  • Objectives: This study assessed the shape and anatomical relationship of the mental foramen (MF) to mandibular posterior teeth in an Indian sub-population. Materials and Methods: In total, 475 existing cone-beam computed tomography records exhibiting 950 MFs and including the bilateral presence of mandibular premolars and first molars were assessed. Images were evaluated 3-dimensionally to ascertain the position, shape, and anatomical proximity of MFs to mandibular teeth. The position and shape of MFs were measured and calculated. The Pythagorean theorem was used to calculate the distance between the root apex of the mandibular teeth and the MF. Results: MFs exhibited a predominantly round shape (left: 67% and right: 65%) followed by oval (left: 30% and right: 31%) in both males and females and in different age groups. The root apices of mandibular second premolars (left: 71% and right: 62%) were closest to the MF, followed by distal to the first premolars and mesial to the second premolars. The mean vertical distance between the MF and the nearest tooth apex calculated on sagittal sections was 2.20 mm on the right side and 2.32 mm on the left side; no significant difference was found according to sex or age. The distance between the apices of the teeth and the MF was ≥ 4 mm (left; 4.09 ± 1.27 mm and right; 4.01 ± 1.15 mm). Conclusions: These findings highlight the need for clinicians to be aware of the location of the MF in treatment planning and while performing non-surgical and surgical endodontic procedures.

Fracture incidence of Reciproc instruments during root canal retreatment performed by postgraduate students: a cross-sectional retrospective clinical study

  • Liliana Machado Ruivo;Marcos de Azevedo Rios;Alexandre Mascarenhas Villela;Alexandre Sigrist de Martin;Augusto Shoji Kato;Rina Andrea Pelegrine;Ana Flavia Almeida Barbosa;Emmanuel Joao Nogueira Leal Silva;Carlos Eduardo da Silveira Bueno
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.4
    • /
    • pp.49.1-49.8
    • /
    • 2021
  • Objectives: To evaluate the fracture incidence of Reciproc R25 instruments (VDW) used during non-surgical root canal retreatments performed by students in a postgraduate endodontic program. Materials and Methods: From the analysis of clinical record cards and periapical radiographs of root canal retreatments performed by postgraduate students using the Reciproc R25, a total of 1,016 teeth (2,544 root canals) were selected. The instruments were discarded after a single use. The general incidence of instrument fractures and its frequency was analyzed considering the group of teeth and the root thirds where the fractures occurred. Statistical analysis was performed using the χ2 test (p < 0.01). Results: Seven instruments were separated during the procedures. The percentage of fracture in relation to the number of instrumented canals was 0.27% and 0.68% in relation to the number of instrumented teeth. Four fractures occurred in maxillary molars, 1 in a mandibular molar, 1 in a mandibular premolar and 1 in a maxillary incisor. A greater number of fractures was observed in molars when compared with the number of fractures observed in the other dental groups (p < 0.01). Considering all of the instrument fractures, 71.43% were located in the apical third and 28.57% in the middle third (p < 0.01). One instrument fragment was removed, one bypassed, while in 5 cases, the instrument fragment remained inside the root canal. Conclusions: The use of Reciproc R25 instruments in root canal retreatments carried out by postgraduate students was associated with a low incidence of fractures.

Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems

  • Xuan Vinh Tran;Khanh Quang Tran
    • Restorative Dentistry and Endodontics
    • /
    • v.46 no.2
    • /
    • pp.30.1-30.13
    • /
    • 2021
  • Objectives: This study was conducted to compare the microleakage and characteristics of the resin-tooth tissue interface between self-etch and etch-and-rinse adhesive systems after 48 hours and 3 months. Materials and Methods: 40 extracted premolar teeth were randomly divided into 2 groups: 1-step self-etch adhesive system - OptibondTM All-In-One, and 2-step etch-and-rinse adhesive system - AdperTM Single Bond 2. Both groups were subjected to 500 thermocycles (5℃-55℃) before scanning electron microscope (SEM) analysis or microleakage trial at 48-hour and 3-month time periods. Results: SEM images showed the hybrid layer thickness, diameter, and length of resin tags of the self-etch adhesive (0.42 ± 0.14 ㎛; 1.49 ± 0.45 ㎛; 16.35 ± 14.26 ㎛) were smaller than those of the etch-and-rinse adhesive (4.39 ± 1.52 ㎛; 3.49 ± 1 ㎛; 52.81 ± 35.81 ㎛). In dentin, the microleakage scores of the 2 adhesives were not different in both time periods (48 hours/3 months). However, the microleakage score of etch-and-rinse adhesive increased significantly after 3 months (0.8 ± 0.63 and 1.9 ± 0.88, p < 0.05). Conclusions: The self-etch adhesive exhibited better long-term sealing ability in dentin when compared to that of the etch-and-rinse adhesive. The greater hybrid layer thickness and dimensions of resin tags did not guarantee reliable, long-lasting sealing in the bonding area.

Pattern of lip retraction according to the presence of lip incompetence in patients with Class II malocclusion

  • Mei Ling Fang;Sung-Hwan Choi;Yoon Jeong Choi;Kee-Joon Lee
    • The korean journal of orthodontics
    • /
    • v.53 no.4
    • /
    • pp.276-285
    • /
    • 2023
  • Objective: The aim of this retrospective study was to compare changes in hard tissue and soft tissue after the four first premolars were extracted with anterior teeth retraction according to the presence or absence of lip incompetence. Methods: Patients who underwent the four first premolars were extracted with anterior teeth retraction were divided into competent (n = 20) and incompetent lip (n = 20) groups. Cephalometric measurements for hard tissue and soft tissue changes were performed pre-treatment and post-treatment. Results: In the competent group, the upper and lower lips retreated by 2.88 mm and 4.28 mm, respectively, and in the incompetent group by 4.13 mm and 5.57 mm, respectively; the differences between the two groups were significant (p < 0.05). A strong positive correlation between retraction of the upper lip and upper incisors was observed in both groups (p < 0.05), whereas a correlation between retraction of the lower lip and lower incisors was only found in the incompetent group. A simple linear regression analysis showed that the pattern of lip retraction following the retraction of the anterior teeth was more predictable in the incompetent group than in the competent group. Conclusions: These findings suggest that the initial evaluation of lip incompetence in patients with skeletal Class II is essential for the accurate prediction of the soft tissue changes following retraction of the anterior teeth in premolar extraction treatment. Therefore, sufficient explanation should be provided during patient consultations.

Maxillary alveolar bone evaluation following dentoalveolar expansion with clear aligners in adults: A cone-beam computed tomography study

  • Marcio Antonio de Figueiredo;Fabio Lourenco Romano;Murilo Fernando Neuppmann Feres;Maria Bernadete Sasso Stuani;Jose Tarcisio Lima Ferreira;Ana Carla Raphaelli Nahas;Mirian Aiko Nakane Matsumoto
    • The korean journal of orthodontics
    • /
    • v.53 no.4
    • /
    • pp.264-275
    • /
    • 2023
  • Objective: To investigate the effects of maxillary orthodontic expansion on the alveolar bone tissue in adult patients treated with aligners by using cone-beam computed tomography. Methods: Thirty patients (22 females and 8 males; mean age: 36.3 years) were treated with Invisalign® aligners. Cone-beam computed tomography and digital models were obtained before (T0) and after (T1) upper arch expansion. The bone thicknesses in the cervical, middle, and apical areas of the incisors, canines, premolar, and first molars were buccally and palatally measured, totaling 96 areas and 2,880 measurements. The buccolingual inclinations and transverse measurements of the teeth were obtained from digital models to correlate them with the bone changes. The statistical tests used were Student's t-test, analysis of variance, and Pearson's correlation tests (p < 0.05). Results: From the 96 areas evaluated, 84 revealed an increase or stability in the alveolar bone thickness and twelve displayed significant bone loss. Bone changes did not correlate with the tooth inclination and transverse measurements. Conclusions: Within the limitation of the present study, mild levels of upper arch expansion obtained with Invisalign® aligners in adult patients did not result in any clinically significant loss of alveolar bone thickness.

Biomechanical analysis for different mandibular total distalization methods with clear aligners: A finite element study

  • Sewoong Oh;Youn-Kyung Choi;Sung-Hun Kim;Ching-Chang Ko;Ki Beom Kim;Yong-Il Kim
    • The korean journal of orthodontics
    • /
    • v.53 no.6
    • /
    • pp.420-430
    • /
    • 2023
  • Objective: The purpose of this finite element method (FEM) study was to analyze the biomechanical differences and tooth displacement patterns according to the traction direction, methods, and sites for total distalization of the mandibular dentition using clear aligner treatment (CAT). Methods: A finite element analysis was performed on four FEM models using different traction methods (via a precision cut hook or button) and traction sites (mandibular canine or first premolar). A distalization force of 1.5 N was applied to the traction site by changing the direction from -30 to +30° to the occlusal plane. The initial tooth displacement and von Mises stress on the clear aligners were analyzed. Results: All CAT-based total distalization groups showed an overall trend of clockwise or counterclockwise rotation of the occlusal plane as the force direction varied. Mesiodistal tipping of individual teeth was more prominent than that of bodily movements. The initial displacement pattern of the mandibular teeth was more predominant based on the traction site than on the traction method. The elastic deformation of clear aligners is attributed to unintentional lingual tipping or extrusion of the mandibular anterior teeth. Conclusions: The initial tooth displacement can vary according to different distalization strategies for CAT-based total distalization. Discreet application and biomechanical understanding of traction sites and directions are necessary for appropriate mandibular total distalization.

Effect of three common hot beverages on the force decay of orthodontic elastomeric chain within a 28-day period: An in vitro study

  • Maziar Nobahari;Fatemeh Safari;Allahyar Geramy;Tabassom Hooshmand;Mohammad Javad Kharazifard;Sepideh Arab
    • The korean journal of orthodontics
    • /
    • v.54 no.3
    • /
    • pp.153-159
    • /
    • 2024
  • Objective: This study aimed to assess the effects of commonly consumed hot drinks on the force decay of orthodontic elastomeric chains. Methods: This in vitro experimental study evaluated 375 pieces of elastomeric chains with six rings placed on a jig. Four rings were stretched by 23.5 mm corresponding to the approximate distance between the canine and the second premolar. Fifteen pieces served as reference samples at time zero, and 360 pieces were randomized into four groups: control, hot water, hot tea, and hot coffee. Each group was further divided into six subgroups (n = 15) according to the different exposure periods. The specimens in the experimental groups were exposed to the respective solutions at 65.5℃ four times per day for 90 seconds at 5-second intervals. The control group was exposed to artificial saliva at 37℃. The force decay of the samples was measured at 1, 2, 7, 14, 21, and 28 days using a universal testing machine. Data were analyzed using repeated-measures analysis of variance. Results: Maximum force decay occurred on day 1 in all groups. The minimum force was recorded in the control group, followed by the tea, coffee, and hot water groups on day 1. At the other time points, the minimum force was observed in the tea group, followed by the control, coffee, and hot water groups. Conclusions: Patients can consume hot drinks without concern about any adverse effect on force decay of the orthodontic elastomeric chains.