• Title/Summary/Keyword: premolar

Search Result 985, Processing Time 0.027 seconds

Fracture resistance of CAD-CAM all-ceramic surveyed crowns with different occlusal rest seat designs

  • Chaturvedi, Saurabh;Alqahtani, Turki;Alsolami, Saleh;Alqahtani, Abdulbari;Das, Gotam;Alsubaiy, Ebrahim
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.36-45
    • /
    • 2021
  • Purpose. To investigate the fracture resistance of monolithic CAD-CAM all-ceramic surveyed crowns with two different occlusal rest seat designs. Materials and Methods. Two maxillary first premolar were prepared for all-ceramic surveyed crowns with wide (2/3rd of buccolingual width of an unprepared tooth) or narrow (1/3rd of buccolingual width of an unprepared tooth) disto-occlusal rest seat (ORS) designs. Eighty monolithic CAD-CAM all-ceramic surveyed crowns were prepared and divided into 4 groups - Group CR, Composite resin material as a control; Group LDS, Lithium disilicate based material; Group ZIPS, zirconia-material (IPS ZirCAD); and Group ZLHT, zirconia- material (CeramillZolidht+). Crowns were cemented on an epoxy resin die with adhesive resin cement. The fracture resistance of crowns was tested with the universal machine. Univariate regression analysis was used. Results. The mean ± standard deviation of maximum failure force values varied from 3476.10 ± 285.97 N for the narrow ORS subgroup of group ZIPS to 687.89 ± 167.63 N for the wide ORS subgroup of group CR. The mean ± standard deviation of maximum force was 1075 ± 77.0 N for group CR, 1309.3 ± 283.9 N for group LDS, 3476.1 ± 285.97 N for group ZIPS, and 2666.7 ± 228.21 N for group ZLHT, with narrow occlusal rest seat design. The results of the intergroup comparison showed significant differences in fracture strength with various material groups and occlusal rest seat designs (P<.001). Conclusion. The zirconia-based all-ceramic surveyed crowns fractured at more than double the load of Lithium disilicate based crowns. The crowns with narrow base occlusal rest seat design had statistically significantly higher fracture resistance than surveyed crowns with wide occlusal rest seat design. The use of narrow occlusal rest seat design in CAD-CAM all ceramic surveyed crowns provides higher fracture resistance, and therefore narrow occlusal rest design can be used for providing esthetics with high strength.

Force changes associated with differential activation of en-masse retraction and/or intrusion with clear aligners

  • Zhu, Ye;Hu, Wei;Li, Shuo
    • The korean journal of orthodontics
    • /
    • v.51 no.1
    • /
    • pp.32-42
    • /
    • 2021
  • Objective: To investigate the three-dimensional forces created by clear aligners on mandibular teeth during differential activation with en-masse retraction and/or intrusion in vitro. Methods: Six sets of clear aligners were designed for differential en-masse retraction and/or intrusion procedures in a first premolar extraction model. Group A0 was a control group with no activation. Groups A1-5 underwent different degrees of retractions and/or intrusions. Each group consisted of 10 aligners. Aligner forces were measured on a multi-axis force/torque transducer measurement system in real-time. Results: In the en-masse retraction groups (A1 and A2), lingual and extrusive forces were observed on the incisors; the canines mainly received distal forces; intrusive forces were seen on the second premolars; and the molars received mesial forces. In the en-masse retraction and intrusion groups (A3, A4, and A5), incisors also received lingual and extrusive forces; canines received distal and intrusive forces; mesial and extrusive forces were seen on the second premolars; and the second molars received distal and intrusive forces. The vertical forces on the incisors did not differ significantly among groups A1, A3, and A5. However, the vertical forces on the second premolars reversed from intrusion in group A1 to extrusion in groups A3 and A5. Conclusions: With clear aligners, the "bowing effect" is seen during en-masse anterior teeth retraction and can be partially relieved by performing en-masse retraction accompanied by anterior teeth intrusion. Vertical control of incisors remained unsolved during en-masse retraction, even when intrusive activation was added to the anterior teeth.

A Study of Radiation Dose Evaluation and Optimization Methods for Intra Oral Dental X-ray in Pediatric Patient (소아 구내촬영 시 방사선량 평가 및 최적화 방안에 대한 연구)

  • Lee, Hyun-Yong;Cho, Yong-In
    • Journal of radiological science and technology
    • /
    • v.44 no.3
    • /
    • pp.195-203
    • /
    • 2021
  • Although intra oral dental x-ray is a lower dose than other radiological examinations, pediatric patients are known to have a higher risk of radiation damage than adults. For this reason, pediatric dental x-ray requires management of dose evaluation and imaging conditions during the examination. In this study, the dose calculation program ALARA-Dental(child/adult) was used to evaluate the organ dose and effective dose exposed to each examination site during intra oral imaging of children during dental radiographic examination, and dose analysis according to the imaging conditions was performed. As a result, the highest organ dose distribution was shown at 0.044 ~ 0.097 mGy in all are as of the mucous membrane of oral cavity except for the maxillary incisors and canines. Also, in the case of the thyroid gland, the maxillary canine and maxillary premolar examination showed 0.027 and 0.020 mGy, respectively, and the dose distribution was 15.4% to 70.0% higher than that of the mandibular examination. As for the effective dose calculated during intra oral imaging, the maxillary anterior and canine examinations showed the highest effective doses of 0.005 and 0.004 mSv, respectively, and the maxillary area examination showed a higher dose distribution on average than the mandible.

Cone-beam computed tomography characterization of the intraosseous vascular canal in the lateral wall of the maxillary antrum

  • Shetty, Shishir Ram;Al Bayatti, Saad Wahby;Marei, Hesham;Shetty, Raghavendra;Abdelmagyd, Hossam Abdelatty;Luke, Alexander Maniangat
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.47 no.1
    • /
    • pp.34-39
    • /
    • 2021
  • Objectives: The purpose of the study was to assess the occurrence, location, and dimensions of the intraosseous vascular canal in the lateral wall of the maxillary antrum using cone-beam computed tomography (CBCT). Materials and Methods: In this retrospective study, we examined 400 CBCT scans from our archive of patients who had earlier reported to a dental teaching hospital in the United Arab Emirates. The prevalence, location, and dimensions of the lateral antral intraosseous canal (LAIC) in the maxillary antrum were evaluated by 2 examiners using standardised methods. A third examiner was consulted in cases of disagreement. Results: The prevalence of LAIC was 62.3% (249 maxillary antra) among the study population. The mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC in the posterior maxillary region was 19.83±3.12 mm. There was a significant difference (P=0.05) between the maxillary molar and premolar regions in mean distance from the most inferior point of the alveolar bone and the inferior border of the LAIC. There was no statistically significant difference in mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC between dentulous and edentulous areas (P=0.1). The G3-intrasinusal type canal less than 1mm in diameter was the most common type of LAIC. Conclusion: This study established the approximate location of the LAIC in a United Arab Emirates cohort, which will assist the oral surgeon in selecting the appropriate site for sinus lift procedures with reduced risk of surgical hemorrhage.

Comparison of soft tissue changes between incisor tipping and translation after premolar extraction

  • Baik, Wonkyeong;Choi, Sung-Hwan;Cha, Jung-Yul;Yu, Hyung-Seog;Lee, Kee-Joon
    • The korean journal of orthodontics
    • /
    • v.52 no.1
    • /
    • pp.42-52
    • /
    • 2022
  • Objective: This study compared soft tissue changes after extraction of the four premolars followed by maximum retraction of the anterior teeth according to the type of anterior teeth movement: tipping and translation. Methods: Patients who had undergone orthodontic treatment involving the extraction of four premolars were retrospectively selected and divided into either the tipping (n = 27) or translation (n = 26) groups based on the retraction of the incisor root apex and the axis changes of the incisors during the treatment period. Lateral pre- and post-treatment cephalograms were analyzed. Results: There were no significant differences between the tipping and translation groups before treatment. The retraction amounts of the root apex of the upper and lower incisors in the tipping group were 0.33 and 0.26 mm, respectively, and 5.02 and 5.31 mm, respectively, in the translation group (p < 0.001). The posterior movements of soft tissue points A and B in the tipping group were 0.61 and 1.25 mm, respectively, and 1.10 and 3.25 mm, respectively, in the translation group (p < 0.01). The mentolabial sulcus angle increased by 5.89° in the tipping group, whereas it decreased by 8.13° in the translation group (p < 0.001). Conclusions: An increased amount of retraction of the incisor root apex led to the increased posterior movement of soft tissue points A and B, and this appeared more distinct in cases involving the lower incisor and lower lip.

Effectiveness of miniscrew assisted rapid palatal expansion using cone beam computed tomography: A systematic review and meta-analysis

  • Siddhisaributr, Patchaya;Khlongwanitchakul, Kornkanok;Anuwongnukroh, Niwat;Manopatanakul, Somchai;Viwattanatipa, Nita
    • The korean journal of orthodontics
    • /
    • v.52 no.3
    • /
    • pp.182-200
    • /
    • 2022
  • Objective: This study aims to examine the effectiveness of miniscrew assisted rapid palatal expansion (MARPE) treatment in late adolescents and adult patients using cone-beam computed tomography (CBCT). Methods: Literature search was conducted in five electronic databases (PubMed, Embase, Scopus, Web of Science, and Cochrane Library) based on the PICOS keyword design focusing on MARPE. Out of the 18 CBCT screened outcomes, only nine parameters were sufficient for the quantitative meta-analysis. The parameters were classified into three main groups: 1) skeletal changes, 2) alveolar change, and 3) dental changes. Heterogeneity test, estimation of pooled means, publication bias, sensitivity analysis and risk of bias assessment were also performed. Results: Upon database searching, only 14 full-text articles were qualified from the 364 obtained results. Heterogeneity test indicated the use of the random-effects model. The pooled mean estimate were as follows: 1) Skeletal expansion: zygomatic width, 2.39 mm; nasal width, 2.68 mm; jugular width, 3.12 mm; and midpalatal suture at the posterior nasal spine and anterior nasal spine, 3.34 mm and 4.56 mm, respectively; 2) Alveolar molar width expansion, 4.80 mm; and 3) Dental expansion: inter-canine width, 3.96 mm; inter-premolar width, 4.99 mm and inter-molar width, 5.99 mm. The percentage of expansion demonstrated a skeletal expansion (PNS) of 55.76%, alveolar molar width expansion of 24.37% and dental expansion of 19.87%. Conclusions: In the coronal view, the skeletal and dental expansion created by MARPE was of the pyramidal pattern. MARPE could successfully expand the constricted maxilla in late adolescents and adult patients.

Assessment of postoperative pain after single-visit root canal treatment using rotary and reciprocating file systems: an in vivo study

  • Shaik, Reshma Parveen;Chukka, Ram Sunil;Bandlapally, Anila;Vemuri, Sayesh;Bolla, Nagesh;Basam, Ram Chowdary;Tammineedi, Sravanthi
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.4
    • /
    • pp.267-275
    • /
    • 2022
  • Background: Various instrument kinematics used in single-visit endodontics influence the occurrence of pain after endodontic therapy. This study aimed to evaluate the occurrence of pain after mechanical instrumentation with Hyflex EDM (HEDM) and WaveOne Gold (WOG) during single-visit endodontic therapy. Methods: Sixty patients diagnosed with asymptomatic irreversible pulpitis and normal apical tissues in mandibular premolar teeth were included in the study for single-visit root canal therapy. The patients were divided into two groups (n = 30) according to the rotary instrument used during root canal preparation (group A [HEDM] and group B [WOG]). Pain was evaluated after endodontic therapy at 8, 24, and 48 h intervals using the visual analog scale (VAS). Data obtained were analyzed using the chi-square test, independent t-test, MannWhitney U test, and Wilcoxon matched-pairs test. Results: Statistically significant differences were observed between the two groups (P < 0.001) at 8, 24, and 48 h, with WOG exhibiting less pain than HEDM files. Conclusion: Postoperative pain was lower in the WOG file system than in the HEDM file system after single-visit root canal therapy at 8, 24, and 48 h.

Convergence analysis of cusp variation symmetry of the mandibular second premolars using 3-dimensional virtual models - Focusing on college students in Jeollabuk-do (3차원 가상모형을 이용한 하악 제2소구치 교두 변이 대칭성에 대한 융복합적 분석 - 전북지역 일부 대학생을 중심으로)

  • Nam, Shin-Eun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.317-323
    • /
    • 2022
  • This study aimed to qualitative analyze the cusp variation pattern of the mandibular second premolars using a three-dimensional virtual models, and to analyze the left-right bilateral symmetry with a quantitative analysis of the tooth surface area according to the cusp variation. 127 virtual mandibular second premolars were prepared and individual absolute/relative cusp area, total crown area and groove form were analyzed using RapidForm2004(INUS technology INC, Seoul, Korea). Independent t-test, Kruskal-Wallis test and chi-square were performed. As a result, the groove form showed high bilateral symmetry between the left and right sides. Based on the left side of groove form, the bilateral symmetry was 100.0% for the U pattern, and 73.7% for the H patterned, and 78.9% for the Y pattern(p<.001). The finding could be as a meaningful reference for manufacturing CAD/CAM dental prostheses, and it is expected that further studies will be conducted on more samples including the mandibular second premolar immediately after eruption.

Factors affecting maxillary sinus pneumatization following posterior maxillary tooth extraction

  • Lim, Hyun-Chang;Kim, Sangyup;Kim, Do-Hyup;Herr, Yeek;Chung, Jong-Hyuk;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.4
    • /
    • pp.285-295
    • /
    • 2021
  • Purpose: The aims of the present study were 1) to quantitatively evaluate the extent of sinus pneumatization and 2) to determine the factors affecting sinus pneumatization. Methods: Based on implant treatment records, a list of patients who underwent implant placement on the posterior maxilla was obtained. Among them, patients with pre-extraction and post-extraction (before implant placement) panoramic radiographs were selected. After excluding radiographs with low resolution and image distortion, the radiographs before and after extraction were superimposed using computer software. Subsequently, the extent of sinus pneumatization (the vertical change of the sinus floor) was measured. Simple and multiple mixed models were used to determine the factors affecting sinus pneumatization. Results: A total of 145 patients were eligible for the present investigation. The average extent of sinus pneumatization was 1.56±3.93 mm at 176 tooth sites. Male sex, single tooth extraction, extraction of an endodontically compromised tooth, a class I root-sinus relationship, and sinus membrane thickening >10 mm favored pneumatization, but without statistical significance. The maxillary second molar presented the greatest pneumatization (2.25±4.39 mm) compared with other tooth types. This finding was confirmed in the multiple mixed model, which demonstrated a statistically significant impact of the extraction of a second molar compared with the extraction of a first premolar. Conclusions: Maxillary sinus pneumatization was 1.56±3.93 mm on average. The extraction of a second molar led to the greatest extent of pneumatization, which should be considered in the treatment plan for this tooth site.

Comparative evaluation of peri-implant stress distribution in implant protected occlusion and cuspally loaded occlusion on a 3 unit implant supported fixed partial denture: A 3D finite element analysis study

  • Acharya, Paramba Hitendrabhai;Patel, Vilas Valjibhai;Duseja, Sareen Subhash;Chauhan, Vishal Rajendrabhai
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.2
    • /
    • pp.79-88
    • /
    • 2021
  • Purpose. To assess peri-implant stress distribution using finite element analysis in implant supported fixed partial denture with occlusal schemes of cuspally loaded occlusion and implant protected occlusion. Materials and methods. A 3-D finite element model of mandible with D2 bone with partially edentulism with unilateral distal extension was made. Two Ti alloy identical implants with 4.2 mm diameter and 10 mm length were placed in the mandibular second premolar and the mandibular second molar region and prosthesis was given with the mandibular first molar pontic. Vertical load of 100 N and and oblique load of 70 N was applied on occlusal surface of prosthesis. Group 1 was cuspally loaded occlusion with total 8 contact points and Group 2 was implant protected occlusion with 3 contact points. Results. In Group 1 for vertical load, maximum stress was generated over implant having 14.3552 Mpa. While for oblique load, overall stress generated was 28.0732 Mpa. In Group 2 for vertical load, maximum stress was generated over crown and overall stress was 16.7682 Mpa. But for oblique load, crown stress and overall stress was maximum 22.7561 Mpa. When Group 1 is compared to Group 2, harmful oblique load caused maximum overall stress 28.0732 Mpa in Group 1. Conclusion. In Group 1, vertical load generated high implant stress, and oblique load generated high overall stresses, cortical stresses and crown stresses compared to vertical load. In Group 2, oblique load generated more overall stresses, cortical stresses, and crown stresses compared to vertical load. Implant protected occlusion generated lesser harmful oblique implant, crown, bone and overall stresses compared to cuspally loaded occlusion.