• Title/Summary/Keyword: premolar

Search Result 987, Processing Time 0.029 seconds

EFFECT OF RESTORATION TYPE ON THE STRESS DISTRIBUTION OF ENDODONTICALLY TREATED MAXILLARY PREMOLARS; THREE-DIMENSIONAL FINITE ELEMENT STUDY (수복물의 종류가 근관치료된 상악 제2소구치의 응력분포에 미치는 영향: 3차원 유한요소법적 연구)

  • Jung, Heun-Sook;Kim, Hyeon-Cheol;Hur, Bock;Kim, Kwang-Hoon;Son, Kwon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.8-19
    • /
    • 2009
  • The purpose of this study was to investigate the effects of four restorative materials under various occlusal loading conditions on the stress distribution at the CEJ of buccal. palatal surface and central groove of occlusal surface of endodontically treated maxillary second premolar, using a 3D finte element analysis. A 3D finite element model of human maxillary second premolar was endodontically treated. After endodontic treatment, access cavity was filled with Amalgam, resin, ceramic or gold of different mechanical properties. A static 500N forces were applied at the buccal (Load-1) and palatal cusp (Load-2) and a static 170N forces were applied at the mesial marginal ridge and palatal cusp simultaneously as centric occlusion (Load-3). Under 3-type Loading condition, the value of tensile stress was analyzed after 4-type restoration at the CEJ of buccal and palatal surface and central groove of occlusal surface Excessive high tensile stresses were observed along the palatal CEJ in Load-1 case and buccal CEJ in Load-2 in all of the restorations. There was no difference in magnitude of stress in relation to the type of restorations. Heavy tensile stress concentrations were observed around the loading point and along the central groove of occlusal surface in all of the restorations. There was slight difference in magnitude of stress between different types of restorations. High tensile stress concentrations around the loading points were observed and there was no difference in magnitude of stress between different types of restorations in Load-3.

A comparison of bioresorbable membranes alone or in combination with platelet-derived growth factors and insulin-like growth factors on the periodontal healing of the dehiscence defects in dogs. (성견의 열개형 골 결손부에서 흡수성 차단막과 PDGF-BB 및 IGF-I의 혼합 사용시 치주조직의 치유에 미치는 영향)

  • Cho, Kyoo-Sung;Kim, Chang-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.27 no.1
    • /
    • pp.217-234
    • /
    • 1997
  • The purpose of present study is to compare the effect of treatment using $Guidor^{(R)}$ as a barrier membrane in conjunction with platelet-derived growth factor and insulin like growth factors on experimental dehiscence defects. Following the resection of premolar crowns, roots were submerged. After 12 weeks of healing period, experimental dehiscence defects of 4mm in height and 4mm in width were surgically created on the mid-facial aspect of the lower premolar roots in each of 4 adult dogs. After root planning and demineralization of the root surface with citric acid, the control groups received 4% methylcellulose gel only, the test group I received 4% methylcellulose gel and were covered by $Guidor^{(R)}$ and the test group II were treated with PDGF and IGF and 4% methylcellulose gel with $Guidor^{(R)}$ coverage. Histological and histomorphometric analysis following 8 weeks of healing revealed the following results. 1. The new bone formation showed no statistically significant difference in all groups with $0.59{\pm}0.82mm$($14.03{\pm}19.60%$) for control, $0.70{\pm}0.39mm$($16.30{\pm}9.01%$) for group I, $0.87{\pm}0.76mm$($18.74{\pm}16.03%$) for group II. 2. The new cementum formation showed no statistically significant difference in all groups with $0.54{\pm}0.48mm$($l6.38{\pm}14.57%$) for control, $0.95{\pm}0.38mm$($23.43{\pm}9.30%$) for group I, $1.01{\pm}0.75mm$($22.10{\pm}16.ll%$) for gorup II. 3. The root resorption showed statistically significant differences betweenthe control group and all test groups(p<0.05) with $2.11{\pm}0.53mm$($52.93{\pm}12.32%$) for control, $0.63{\pm}0.27mm$($15.32{\pm}7.05%$) for group I, $0.89{\pm}0.33mm$ ($19.26{\pm}7.11%$) for group II. On the bases of these results, there were no statistically difference between treatment using resorbable membrane and resorbable membrane in conjunction with PDGF and IGF in the dehiscence defects, where it was difficult to maintain space. The use of membrane seemed to be more effective in the inhibition of root resorption.

  • PDF

AN IN-VITRO WEAR STUDY OF DENTAL PORCELAINS AND HUMAN ENAMEL (치과용도재에 의한 법랑질 마모에 관한 연구)

  • Lee, Young-Kook;Lee, Sun-Hyung;Yang, Jae-Ho;Chung, Hun-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.1
    • /
    • pp.51-70
    • /
    • 1999
  • Dental porcelain is one of the materials of choice for restoration where esthetics is of concern, but has a considerable potentials of wear. The wear of enamel is variable when opposed by different porcelain systems and surface conditions, and the exposed dentine and opaque porcelain due to clinical failure is expected to have high potentials of wear. The purpose of this study was to investigate the wear effects of self-glazed, polished incisal porcelain. polished dentine and opaque porcelain against human enamel in the laboratory by use of a pin-on-disk type wear tester. 4 types of dental porcelain($Vita-{\Omega}$, Ceramco-II, Vintage powder $Vita-{\alpha}$ of In-Ceram system) and type IV gold alloy as cotrol group were used for test specimens. Intact buccal cusps of maxillary premolar were used for enamel specimens, and the cusp converged to a point and was devoid of visible abrasion, caries, decalcification. The upper part was the cusp of a maxillary premolar and the lower part was a porcelain specimen. The enamel wear was deter-mined by weighing the cusp before and after each test. Surface profilometer was used to quantitate wear of the porcelain specimens. Vicker's hardness tester was used to evaluate the surface hardness of test specimens. The SEM was used to evaluate the wear surfaces. The results were as follows : 1 Self-glazed porcelain produced more enamel wear than polished porcelain, especially the enamel wear of $Vita-{\alpha}$ self-glazed porcelain was 3.2 times more than that of other groups. 2. Opaque porcelain produced least porcelain wear, $Vita-{\alpha}$ self-glazed porcelain produce greatest porcelain wear, but there was no statistically significant difference between the groups(p>0.05). 3. The enamel wear of dentine porcelain was 3.8 times more than that of polished inisal porcelain(p<0.05), and the enamel wear of opaque porcelain was 1.9 times more than that of polished inisal porcelain, but there was no statistically significant difference between the groups(p>0.05) 4. Overglazed porcelain produced less enamel wear than self-glazed porcelain, and more enamel wear than polished porcelain, but there was no statistically significant difference between the groups(P>0.05). 5. The hardness number of $Vita-{\Omega}$ dentine and Ceramco-II opaque porcelain was larger, but that of Vintage dentine and $Vita-{\alpha}$ self-glazed porcelain was similar to other groups. 6. Examination of SEM photographs revealed that overglazed porcelain had smoother surface than self-glazed porcelain, and self-glazed porcelain had smoother surface than polished porcelain. Much polishing scratches and larger porosities were observed on the opaque porcelain specimen, and much polishing scratchess and small porosities were observed on the dentine porcelain specimen.

  • PDF

A CASE OF SUPERNUMERARY TEETH IN THE MANDIBULAR INCISOR REGION : (하악에 발생한 과잉치의 치험례)

  • Park, Jung-Ah;Choi, Nam-Ki;Kim, Seon-Mi;Jang, Hee-Suk;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.4
    • /
    • pp.644-648
    • /
    • 2005
  • Supernumerary tooth was resulted from excessive proliferation of dental lamina and associated with familial tendency and a congenital syndrome such as Cleidocranial dysostosis or Gardner's syndrome. Incidence reports identify a range of $0.3{\sim}0.8%$ in primary dentition, $1.0{\sim}3.5%$ in permanent dentition with males being affected twice as frequently as females, maxilla nine times as frequently as mandible. The most common supernumerary tooth is the mesiodens, which located between the maxillary central incisors, and the next common site is the fourth molar and lateral incisors. Supernumerary teeth are uncommon in the mandible, but premolars are the most common supernumerary teeth and occurrence is very rare in the incisor region of the mandible and the incidence is 2%. We need a early diagnosis and appropriate treatment plan because of possiblilty of diastema and eruption failure displacement, rotation of the associated permanent teeth, root resorption and dentigerous cyst with presence of the supernumerary teeth. In this two case, one supernumerary tooth located in the mandibular incisor region, the other supernumerary tooth located in premolar region. We could get normal alignment of mandibular dentition by extraction and orthodontic treatment.

  • PDF

STABLIZATION OF THE EARLY ERUPTED FIRST PREMOLAR WITH FIXED APPLIANCE (고정식 장치를 이용한 조기 맹출 소구치의 안정화)

  • Hwang, JI-Won;Kim, Seong-Oh;Choi, Hyung-Jun;Choi, Byung-Jai;Son, Heung-Kyu;Lee, Jae-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.1
    • /
    • pp.62-67
    • /
    • 2011
  • Early eruption refers to an accelerated eruption of a tooth beyond the normal eruption period. The clinical findings of an early erupted tooth with little formation of crown and/or root include severe mobility, pain on chewing, hypocalcification of the enamel, and inclination, displacement, and rotation of the tooth. The radiographic findings include underdeveloped root and insufficient bone support. Early eruption of a permanent tooth can cause several complications such as chronic trauma, pain, edema, an increased rate of premolar impaction and tooth displacement and/or rotation. Therefore, when a permanent tooth erupts earlier than its normal eruption period with accompanying symptoms, appropriate treatments should be done as soon as possible. A female patient of age 7 without any systemic disease was referred from a local dental clinic with chief complaint of severe mobilities and pain in both upper first premolars. According to the clinical and radiographic examinations, the permanent teeth erupted earlier with barely formed roots, severe mobilities, edema, and pain. This case is to report the successful accomplishment of root formations and stabilization of teeth after applying intraoral fixed appliances using bands and spurs for 14 months.

Miniscrew Installation Area and Condition on Maxillary Palatal Side (상악구개측 미니스크류 식립위치 및 조건)

  • Lee, Ki-Yeon;Lee, Jin-Woo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.61-71
    • /
    • 2009
  • Anchorage control is important in orthodontic treatment. Recently miniscrew is widly used as maximum anchorage in orthodontic treatment, and then it is important to install miniscrew safely without damaging adjacent anatomic structure. In a view of Miniscrew's stability, maxilla is unfavorable than mandible, and moreover maxillary soft buccal bone has disadvantage on stability. so palatal area comes into notice for installation area. We measured distance between palatal roots and bone thickness at midpalatal area using 3D computed tomography, and have found following results. 1. On the comparison of distance between palatal roots, the distance between 2nd premolar and 1st molar was significantly longest and the distance between premolars was significantly shortest. 2. Going toward lateral area from midpalatal suture and posterior area from zero point, bone thickness significantly became shorter and shorter. And 5.0mm palatal sagittal plane has more significance decrease of bone thickness than 2.5mm palatal sagittal plane. According to these results, we can conclude that the palatal installation of miniscrew between 2nd premolar and 1st molar is safest. And it is more safe that comes closer to midpalatal suture and to anterior area in regard to incisive canal.

Comparison of Stress of the Abutment Teeth and Denture Base in Distal Extension Removable Partial Dentures Retained Konus Crown, Precision Attachment and RPI Clasp with the Occlusal Load Application (유리단 국소의치의 교합하중 적용시 이중금관, 어태치먼트 및 RPI clasp 유지장치에 따라 지대치와 의치상에 미치는 응력 비교)

  • Jun, In-Sik;Kim, Bu-Sub;Chung, In-Sung
    • Journal of Technologic Dentistry
    • /
    • v.28 no.2
    • /
    • pp.331-346
    • /
    • 2006
  • Free-end partial dentures, which are supported by teeth surrounded by dental root membranes and elastic mucous membrane tissues, may cause stress to the abutment teeth due to external force imposed on the denture base, increase the mobility of the abutment teeth, and bring about a change in the periodontal tissue. General retainers used in partial dentures are categorized into clasp, attachment, and Konus crown. Stress imposed on the abutment teeth and mobility of the denture base have relations with the lifetime of a crown and abutment teeth, and have direct relations with the chewing ability. Thus, a need arises to make a comparative analysis of stress of the three direct retainers on the abutment teeth and interpret the mobility of the denture base. This study designed three kinds of removable partial dentures (one kind of attachment partial denture, one kind of Konus crown partial denture, and one kind of clasp partial denture), and fabricated Dentiforms of bilateral partial dentures (Kennedy Class I) with lower left 1st premolar and lower right 1st and 2nd premolars being as the abutment teeth. A strain gauge was installed in the mesial and distal surface of the lowerr left 1st premolar (No. 34) of the fabricated dentiform and in the lower part of the denture base, and installed were a clasp partial denture, an attachment partial denture, and a Konus crown partial denture. Then, the vertical static load of 5kgf and 7.5kgf at the occlusion surface of the lower left No. 6 molar was generated for a total of 20 frequencies of load each using a push-full gauge, and thus a change in the output of the strain gauge was measured. With the respective application of Konus crown, attachment and RPI clasp in the free-end partial denture, surveyed was the distribution of stress imposed on the abutment teeth and the denture base according to the location of occlusion force load so as to come up with the following results. 1. Konus crown and attachment partial dentures generated much stress, and more stress on the abutment teeth than RPI clasp dentures did. Attachment dentures tended to further intensify stress on the abutment teeth than Konus crown dentures did. 2. Attachment dentures and Konus dentures imposed less stress on the denture base than RPI clasp dentures did. There was no stress difference between Attachment and Konus crown dentures. 3. Dentures that were designed with the application of retainers using sturdy linkage methods tended to be less mobile.

  • PDF

Changes in occlusal force and occlusal contact area after orthodontic treatment (교정 치료 후 교합력, 교합면적의 변화)

  • Choi, Yoon-Jeong;Chung, Choo-Ryung J.;Kim, Kyung-Ho
    • The korean journal of orthodontics
    • /
    • v.40 no.3
    • /
    • pp.176-183
    • /
    • 2010
  • Objective: This study was performed to evaluate functional changes of occlusion after orthodontic treatment by measuring the occlusal force (OcFr) and occlusal contact area (OcAr), and to compare OcFr and OcAr change according to premolar extractions. Methods: Data were obtained from 74 patients who had finished orthodontic treatment using fixed appliance aged between 18 and 40 years. Subjects were divided into groups who had four premolars extractions or non-extraction (Male extraction-16, Male nonextraction-18, Female extraction-19, Female nonextraction-21). All subjects were asked to bite pressure-sensitive sheets into maximum intercuspation with maximum bite force, and OcFr and OcAr were evaluated by measuring the sheet with a CCD camera. Records were taken right after debonding, 1 week, 1 month, 3 months, 6 months and 1 year after debonding. Results: OcFr and OcAr increased gradually in all groups during the 1 year retention period (p < 0.05). Male groups showed higher OcFr and OcAr than female groups throughout the retention periods (p < 0.05). There were no statistically significant differences of OcFr and OcAr between extraction and non-extraction groups in both males and females (p > 0.05). Conclusions: Occlusion was improved functionally throughout the 1 year retention, and premolar extraction did not induce a decline in the functional aspect of occlusion.

Study of the relationship between the indication rod of stent on implant CT and the real path of implant fixture insertion considering residual ridge (임플란트 CT에서 방향 표시자의 방향과 잔존골을 고려한 임플란트 식립 방향의 관계에 관한 연구)

  • Kim Do-Hoon;Heo Min-Suk;Lee Sam-Sun;Oh Sung-Ook;Choi Hang-Moon;Jeon In-Seong;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.33 no.2
    • /
    • pp.79-83
    • /
    • 2003
  • Purpose : To assess the relationship between the direction of the indicating rod of the radiographic stent for ideal prosthetic design and the actual possible path of implant fixture placement when residual ridge resorption is considered. Materials and Methods: The study materials consisted of 326 implant sites (male 214 cases and female 112 cases) from a total of 106 patients (male 65 patients and female 41 patients) who desired implant prostheses. Computed tomography of patients were taken and reformatted using ToothPix/sup (R)/ software. Bony defects, bony sclerosis, the change of the direction of indicating rod, and root proximity of the adjacent teeth were examined on the CT-derived images. Results: The rate of the irregular crestal cortex was relatively high on premolar and molar area of maxilla. Mandibular molar area showed relatively high rate of focal sclerosis on the area of implant fixture insertion. The position of the indicating rods were relatively acceptable on the molar areas of both jaws. However, the position of the indicating rods should be shifted to buccal side with lingual rotation of the apical end on maxillary anterior teeth and premolar area. Conclusion: Clinically determined rod direction and position of the indicating rod for implant placement was not always acceptable for insertion according to the reformatted CT images. The pre-operative treatment plan for implant should be determined carefully, considering the state of the alveolar bone using the reformatted CT images.

  • PDF

Reference line-pair values of panoramic radiographs using an arch-form phantom stand to assess clinical image quality

  • Choi, Da-Hye;Choi, Bo-Ram;Choi, Jin-Woo;Huh, Kyung-Hoe;Yi, Won-Jin;Heo, Min-Suk;Choi, Soon-Chul;Lee, Sam-Sun
    • Imaging Science in Dentistry
    • /
    • v.43 no.1
    • /
    • pp.7-15
    • /
    • 2013
  • Purpose: This study was performed to suggest reference line-pair values of panoramic images with clinically desirable qualities using an arch-form phantom stand. Materials and Methods: The line-pair test phantom was chosen. A real skull model was selected for setting the arch-form model of the phantom stand. The phantom stand had slits in four regions (incisor, premolar, molar, TMJ). Four raw images of the test phantom in each region and one raw image of the real skull were converted into 50 test phantom images and 50 skull phantom images with various line-pair values. 50 post-processed real skull phantom images were divided into 4 groups and were randomly submitted to 14 evaluators. Image quality was graded on a 4 point scale (1. good, 2. normal, 3. poor but interpretable, and 4. not interpretable). The reference line pair was determined as the first line-pair value scored less than 2 points. Result: The mean scores tended to decrease as the line-pair values increased. The reference line-pair values were 3.19 LP/mm in the incisor, 2.32 LP/mm in the premolar and TMJ, and 1.88 LP/mm in the molar region. Conclusion: Image quality evaluation methods and criteria should be able to assess various regions considering the characteristics of panoramic systems. This study suggested overall and regional reference line-pair values and established a set of standard values for them.