• Title/Summary/Keyword: premolar

Search Result 987, Processing Time 0.031 seconds

A comparative study on the accuracy of digital subtraction radiography according to the aquisition methods of reconstructed images (재구성영상 형성방법에 따른 디지털영상공제술의 정확성 비교연구)

  • Huh Young-June;Jeon In-Seong;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;Kim Jong-Dae
    • Imaging Science in Dentistry
    • /
    • v.32 no.2
    • /
    • pp.107-111
    • /
    • 2002
  • Purpose : To compare the accuracy of digital subtraction images acquired by two different methods different in positioning four reference points for geometrical standardization. Materials and Methods : A total of 36 digital radiographic images of 6 volunteers were taken at the areas of the incisor, premolar, and molar of both the maxilla and mandible using the Digora system. Each image was moved 4 mm vertically and horizontally. Four oral and maxillofacial radiologists performed digital subtraction radiography between the paired images before and after movement using Emago (Oral Diagnostic Systems, Amsterdam, The Netherlands) and Sunny (Biomedisys Co., Seoul, Korea). The standard deviation of the internal gray value in Region of Interest (ROI) was statistically analyzed between the two programs using the paired t-test. Results : The standard deviation of pixel gray values from the digital subtraction images using the Sunny program were lower than that of the Emago program (p<0.05). All observers showed significant differences between each other when the Sunny program was used (p<0.05), but one observer showed a significantly higher score than other observers when they used Emago (p<0.05). The standard deviations of premolar area from both Sunny and Emago programs were significantly higher than those of anterior and molar regions (p<0.05). Conclusion: The subtracted images using the Sunny program were more accurate and sensitive than those taken using the Emago program.

  • PDF

The success rate of Mg-incorporated oxidized implants in partially edentulous patients: a prospective clinical study (부분 무치악 환자에서 마그네슘 이온주입 임플란트의 성공률에 대한 전향적 임상연구)

  • Choi, Su-Jung;Yoo, Jung-Ho;Lee, Ku-Bok;Kim, Jin-Wook
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.3
    • /
    • pp.176-183
    • /
    • 2012
  • Purpose: This study examined the clinical success rate of Mg titanate implants (M Implant system, Shinhung, Korea), which employ a Mg coating method, by evaluating the marginal bone loss and implant stability using radiographs and Osstell$^{(R)}$, over a 1 year. Materials and methods: The locations of the implants placement were divided into 4 areas; the maxillary and mandibular premolars and molars. In the maxilla, 8 and 9 implants were inserted in the premolar and molar areas, respectively. In the mandible, 11 and 51 implants were inserted in the premolar and molar areas. Marginal bone loss and ISQ of all implants (79) were measured after insertion, mounting the prosthetic appliance, and 1, 3, 6, and 12 months after loading. The marginal bone loss was measured from the radiograph using XCP bite, which was customized, and the implant stability measured using Osstell$^{(R)}$. Fisher's exact test (${\alpha}$=.05) was used to compare the success rates of each region. Results: The mean marginal bone loss for the upper and lower jaws were 1.537 mm and 1.172 mm. The mobility showed a non-significant reduction or increase according with time. The success rates were accounted for 94.12% and 98.39% in the upper and lower jaws; the premolars and molars were accounted for 100% and 96.67%. The two cases of early failure resulted from failure of primary stability during implant insertion. The late failures were not observed for 1 year after adding a loading to the implants. Conclusion: The Mg titanate implant showed good primary stability and good clinical results in both healing and function.

Clinical convergence angle and rounding radius on tooth preparation for zirconia all-ceramic crown (지르코니아 전부도재관 지대치 삭제시 축면 경사각과 만곡 반경에 대한 조사)

  • Kim, Hye-Eun;Woo, Yi-Hyung;Pae, Ah-Ran;Kim, Hyeong-Seob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.22-28
    • /
    • 2011
  • Purpose: This article attempted to examine how teeth for restoration is made in a clinical practice and utilize it as future educational material of teeth formation and basic data for additional research. Materials and methods: This experiment investigated the models sent to milling center for production of zirconia crowns. After scanned with Lava CAD/CAM System (3M ESPE, Seefeld, Germany), they are measured on 'ImageJ (version 1.32j, National Institutes of Health, USA)' program and compared and analyzed. Convergence angle from mesio-distal surfaces and bucco-lingual surfaces of each teeth are measured. Also, bucco-lingual diameter of the region lowered as much as 0.4 mm from incisal edge in anterior teeth except canines.(This measure is defined as the Peak 0.4) The analysis of data between each group was conducted by Windows SPSS statistic program, and was proved significant on 95% confidence level by independent t-test, one-way ANOVA and multiple analysis (Sheff${\'{e}}$ test). Results: The mean value of convergence angle was $18.67^{\circ}$ It is ranked as molar ($26.70^{\circ}$) > premolar ($16.87^{\circ}$) > anterior teeth ($14.81^{\circ}$) in the order of mesio-distal convergence angle; anterior teeth ($22.32^{\circ}$) > molar ($20.93^{\circ}$) > premolar ($15.41^{\circ}$) in the order of bucco-lingual convergence angle. The mean value of Peak 0.4 was 1.18 mm. Conclusion: Convergence angle of abutment of zirconia all ceramic crown has difference depending on the location in the arch. Due to the nature of production of zirconia all ceramic crown, convergence angle of abutment and line angle finishing degree can have an effect on internal suitability of restoration.

CONSERVATIVE ENDODONTIC TREATMENT OF PERMANENT TEETH WITH PERIAPICAL LESIONS : CASE REPORTS (치근단 병소를 가진 영구치의 보존적 치수 치료)

  • Yoon, Young-Mi;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.38 no.3
    • /
    • pp.276-283
    • /
    • 2011
  • Recently, undifferentiated stem cells which exist in dental papillae of immature permanent teeth were newly discovered and these stem cells appear to be the origin of ameloblasts associated with the formation of root dentin. When treating immature permanent teeth, the preservation of these stem cells induce the continuous formation of the root. Therefore, it is reported that minimal invasion to periapical region in immature permanent teeth with periapical inflammation resulted in good-healing pattern in clinical and radiographic examination. In this case, a 10 year-old boy(mandibular right premolar) and a 8 year-old girl(maxillary left premolar) who visited the department of pediatric dentistry at Chosun University Dental Hospital were diagnosed with pulp necrosis and periapical abscess in clinical and radiographic examination. Endodontic instrumentation to the periapical region was limited and MTA(Mineral Trioxide Aggregate) was applied into the pulp canal. The periodic checks showed healing of periapical abscess and the development and growth pattern of roots. In permanent teeth with pulp necrosis and periapical abscess, preservation of pulp and dental papillae in the periapical region showed good prognosis during the periodic examinations. Therefore, a lot of clinical examination and long-term evaluation of conservative pulp treatment in immature permanent teeth are expected to be necessary.

Histologic Study Of Different Bioceramic Implants In Intrabony Defects (골내낭에 매식된 수종의 생체요법재료에 대한 조직학적 연구)

  • Lee, Chul-Woo;Choi, Sang-Mook;Han, Soo-Boo;Park, Sang-Hyun;Kim, Hyeon-Jong
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.27-46
    • /
    • 1996
  • The purpose of this study was designed to compare with the effects of 4 different surface active bioceramics on the healing process of alveolar bone defects in dogs. Artificial alveolar bone defects depth 4-6mm, width 3-4mm) were created with # 6 round bur at interproximal areas of maxillary canine, maxillary 2nd premolar, mandibular canine, and mandibular 3rd premolar. porous hydroxyapatite(Interpore $200^R$) , 45S5 bioglass, CJ4/lOC crystalline glass, and JJ crystalline glass were implanted in intrabony defects randomly. Experimental groups were divided into 4 categories according to its implant material. After implantation, all groups were examined postoperatively 4 weeks to 12 weeks. 3 dogs was selected randomly and sacrificed after vascular perfusion with 2.5% glutaraldehyde at every 4 weeks. Tissue blocks with surroundig alveolar bone and soft tissues were removed and immersed in formaldehyde/glutaraldehyde fixative. After 20 weeks decalcification with EDTA and formic acid, sections were made and observed under light microscope and transmission electron microscope. In all experimental groups, the encapsulation of inactive connective tissue was observed around graft particles in 4 weeks. As time elapsed, the thickness of surrounding connective tissue was decreased. Osteoconductive bone growth pattern was seen apparently in all groups. CJ4/lOC crystalline glass showed the most active bone formation until 8 weeks. 45S5 bioglass was, however, the most active in new bone formation at 12 weeks. Though there was difference in resorption rate among grafting materials, the size of graft particles was decreased gradually. 45S5 bioglass was resorbed faster than the others. On the other hand, porous hydroxyapatite was degraded most slowly. Phagocytosed particulate matters was observed in the cytoplasm of multinuclear multinuclear giant cell and macrophage under transmission electron microscope. The results suggested suggested that 45S5 bioglass and CJ4/lOC crystalline glass may have some enhanced reparative potential when compared to porous hydroxapatite in the treatment of periodontal defeds. JJ crystalline glass reguires a further investigation of the safety of its use.

  • PDF

The incidence of the abutment screw loosening and its affecting factors in posterior implant restorations (구치부 임플란트 고정성 수복물에서의 지대주 나사 풀림 현상과 이에 영향을 미치는 요인)

  • Hong, Su-Jung;Bae, Jung-Yoon;Kim, Hyun-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.3
    • /
    • pp.212-217
    • /
    • 2018
  • Purpose: This study was to assess clinically the incidence of abutment screw loosening of posterior implant-supported fixed prosthesis and its affecting factors. Materials and methods: 391 implant-supported crowns restored from January 2013 to January 2016 were included in this study. All restorations were fabricated with either a single crowns or a splinted crown, and cemented with temporary cement. The incidence of abutment screw loosening is investigated and gender, restoration position, opposing teeth, restoration type, abutment connection type were assessed as possible factors affecting abutment screw loosening. Results: During the observation period (2 - 5 years), abutment screw loosening was found in 29 restorations (7.4%). It took 3 to 48 months (means 19.5 months) to loose the screw, and three of these implants were fractured. Among the factors considered, there were statistically significant differences at abutment screw loosening rate between molar group (9.4%) and premolar group (2.6%) (P<.019). According to the type of opposing teeth, there were statistically significant differences between nature teeth (74.7%) and implant (25.0%), removable denture (3%) (P<.019). The other possible factors did not have a significant effect on loosening of the abutment. Conclusion: The incidence of abutment screw loosening in posterior restoration was 7.4%. Abutment screw loosening were more likely to occur in molars group than premolar group, and according to the opposing teeth, there were the greatest frequency in nature teeth than implant and removal denture. There was a statistically significant difference.

THE DELAYED DEVELOPMENT OF MANDIBULAR SECOND PREMOLARS - A PITFALL FOR MISDIAGNOSIS OF CONGENITAL ABSENCE (선천 결손으로 오인될 수 있는 하악 제2소구치의 발육지연)

  • Woo, Youn-Sun;Jeong, Tae-Sung;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.28 no.3
    • /
    • pp.369-373
    • /
    • 2001
  • The congenital missing of mandibular second premolars is among the common dental anomaly in children. When a second premolar is diagnosed as congenitally missed, we should consider many factors influencing the treatment plan such as patient's age, states of roots of 2nd primary molar, degree of crowding, skeletal growth pattern, facial profile, procumbency of the incisor and lower facial height, etc. The mineralization of the second premolars begins in the majority of cases at the age of $2\sim2\frac{1}{2}$ years, but this period varies more widely than those for other permanent teeth. Also, mandibular second premolars show the greatest variations in differentiation and calcification. For this reason, aplasia of this group of teeth cannot be diagnosed at early age and with the same degree of certainty. From the clinical studies with 2 cases and some literature review on late development of second premolars, it could be summarized as follows : 1. The 2 cases showed marked delay in the development of mandibular second premolars. 2. After the crypt formation, the speed of calcification seemed nearly normal, suggesting that the delay was due to differentiation rather than calcification. 3. When one is encountered with similar conditions, it would be desirable to consider the possibility of delayed tooth development.

  • PDF

A STUDY ON THE PRE-ERUPTIVE POSITIONAL CHANCE OF THE LOWER THIRD MOLAR FOLLOWING ORTHODONTIC TREATMENT (교정치료에 따른 미맹출 하악 제3대구치의 위치 변화에 관한 연구)

  • Lee, Kyoung-Won;Bae, Seong-Ryol;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.26 no.1 s.54
    • /
    • pp.105-111
    • /
    • 1996
  • Most of orthodontic cases are treated with extraction of certain teeth, which influence the pre-eruptive movement of the lower third molar The purpose of this study was to evaluate the positional change of lower third molar following orthodontic treatment. Pre- and post-treatment pantomograms of 163 orthodontic patients (77 nonextraction group, 78 first premolar- extraction group, 8 second molar- extraction group) were analyzed in terms of the mesiodistal and buccolingual angles of lower third molar. The results were as follows. 1. The change of the mesiodistal angle of lower third molar by orthodontic treatment was significant in second molar-extraction group. 2. The mesiodistal angle of lower third molar in pre-treatment was significantly correlated to the mesiodistal angle in post-treatment and/or the change of the mesiodistal angle by treatment. 3. The change of the buccolingual angle of lower third molar by orthodontic treatment was significant in non -extraction group or first premolar-extrction group. 4. The change of the buccolingual angle of lower third molar by treatment was significantly correlated to the mesiodistal angle in post-treatment, the change of the mesiodistal angle by treatment, the buccolingual angle in pre-treatment or the buccolingual angle in post-treatment.

  • PDF

A STUDY OF MANDIBULAR DENTAL ARCH FORM OF THE KOREAN WITH NORMAL OCCLUSION (한국인 정상교합자의 하악치열궁 형태에 관한 연구)

  • Nam, Jong-Hyun;Lee, Ki-Soo
    • The korean journal of orthodontics
    • /
    • v.26 no.5 s.58
    • /
    • pp.535-546
    • /
    • 1996
  • The purpose of this study was to classify mandibular dental arch forms based on Raberin's method, and to compare Raberin's arch forms with that of the Korean's, and to designate arch form of bracket level according to distance between cusp tip and buccal surface of bracket level. The sample consisted of 159 mandibular dental casts showing normal occlusion which was taken from 62 males and 97 females of the Korean, aging from 13 to 25 years. The model was taken by X-ray. The landmarks were cusp points which expressed the mandibular dental arch line of cusp tips and buccal points which were measured from cusp tips to buccal surfaces of bracket level. The landmarks on the film were digitized, and measurements and statistics were performed. The results were as follows; 1. The models were classified as type 1, type 2, type 3, type 4 and type 5 by the author, and polynomial functions of the six degree and R-square values were calculated using statistical method, and each calculated equations explained each group with the least R-square value of 0.97, and each arch forms' were plotted. 2. The distribution of type 1 was $17.6\%$, type 2 $20.8\%$, type 3 $20.8\%$, type 4 $16.3\%$ and type 5 $24.5\%$. 3. The Korean arch form was characterized by larger width, smaller height compared to the French arch form. 4. The designated arch form of bracket level, viz the distance between cusp point and buccal point was calculated. The distance between cusp point and buccal point of incisor was 1mm, canine 1.9mm, first premolar 2.5mm, second premolar 2.6mm, first molar 2.7mm and second molar 2.7mm.

  • PDF

A FINITE ELEMENT ANALYSIS ON THE DEFLECTION OF IMC IN THE TOOTH AND IMPLANT SUPPORTED FIXED PARTIAL DENTURE (치아 및 임플랜트 지지 고정성 국소의치에서 내가동 연결장치의 변형에 관한 유한요소법적 분석)

  • Kim, Chang-Ho;Choi, Ah-Young;Kay, Kee-Sung;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.2
    • /
    • pp.308-329
    • /
    • 1997
  • A lot of the research paper was reported about the result of influence of IMC (Intra-mobile connector) in the IMZ implant placed solely in the alveolar bone, but reports about the effect of IMC on functional load at state of connecting with natural teeth ere rare. The major propose of this study was find the mechanical character of IMC itself by using the finite element analysis program after simulated variance of condition connected with the natural teeth and implant on funcional load. When first and second premolar was lost, IMZ implant was placed with a diameter of 3.3mm and a length of 13mm with IMC in second premolar area. Rigid connection was done and the non-figid connention was located on the female part of the canine abutment and the implant respectively and then both the infraocclusion of $30{\mu}m$ and the non-infraocclusion under the load of 40kg applied to the portion of the natural teeth, the pontic and the implant. The displacement and the stress of it was estimated and analyzed IMC itself of the rigid connection and the non-rigid connection was grouped. The following result were obtained. 1. In all groups, the displacement of Y-axis was greater than that of X-axis and the aspect of displacement showed that IMC was displaced downward and to the center. 2. There was no differences in the displacement of IMC regardless of the connection type. 3. In the displacement of IMC, I 4 was the least, I 1 and I 3 are similar and I 2 was the greatest. 4. There was no differences in the peak value of maximal stress of IMC regardless of the connection type. 5. In the peak value of maximal stress of IMC, I 4 was the least, I 1 and I 3 were similar, and I 2 was the largest.

  • PDF