• Title/Summary/Keyword: preliminary test estimation

Search Result 56, Processing Time 0.021 seconds

A Study on the Life Characteristic of an Automotive Water-pump Bearing Using the Accelerated Test Method (가속시험법을 활용한 자동차용 워터펌프 베어링의 수명특성에 관한 연구)

  • Yang, Hui Sun;Shin, Jung Hun;Park, Jong Won;Sung, Baek Ju
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.35-41
    • /
    • 2015
  • A water-pump located in the cooling area of a car circulates cooling water. A particular bearing element, known as a water-pump bearing, installed in the rotating part carries the entire load. The failure of this water-pump bearing has a direct impact on the failure of the automobile engine, and so securing its reliability is crucial. Several researchers have examined the design principles of the water-pump bearing, but there are no reports on the life characteristic of the bearing yet. Herein, we report the construction of test equipment to reproduce the spalling of the roller contact, which is the main failure mode of the chosen water-pump bearing. We chose the radial load as an accelerated stress factor and validated the failure mode by monitoring the surface defects. We conducted the accelerated life test after determining the accelerated stress level through a combination of finite element analysis and a preliminary test. In the life tests, we used an accelerometer to perform failure diagnosis. In the last stage of this study, we present a statistical reliability analysis. Thus, we fully estimated the shape parameter of the water-pump bearing, accelerating level on the load , and the lifetime (MTTF and B10 life) under real use conditions, and finally proposed an interval estimation value considering the uncertainty of the estimated value.

Accuracy Evaluation of Bi-medium Deep Body Thermometer Based on Finite Element Simulation (유한 요소 시뮬레이션을 이용한 이중 매질 심부 체온계의 정확도 평가)

  • Sim, S.Y.;Ryou, H.S.;Kim, H.B.;Jeong, J.H.;Lee, S.J.;Kim, S.M.;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.160-168
    • /
    • 2014
  • Continuous body temperature monitoring is useful and essential in diverse medical procedures such as infection onset detection, therapeutic hypothermia, circadian rhythm monitoring, sleep disorder assessment, and gynecological research. However, the existing thermometers are too invasive or intrusive to be applied to long-term body temperature monitoring. In our previous study, we invented the bi-medium deep body thermometer which can noninvasively and continuously monitor deep tissue temperature. And the ratio of thermal resistances expressed as K-value should be obtained to estimate body temperature with the thermometer and it can be different under various measurement environments. Although the device was proven to be useful through preliminary simulation test and small group of human study, the experimental environment was restrictive in our previous approach. In this study, a finite element simulation was executed to obtain the K-value and evaluate the accuracy of bi-medium thermometer under various measurement environments. In addition, K-value estimation equation was developed by analyzing the influence of 5 measurement environmental factors (medium length, medium height, tissue depth, blood perfusion rate, and ambient temperature) on K-value. The results revealed that the estimation accuracy of bi-medium deep body thermometer based on computer simulation was very high (RMSE < $0.003^{\circ}C$) in various measurement environments. Also, bi-medium deep body thermometer based on K-value estimation equation showed relatively accurate results (RMSE < $0.3^{\circ}C$) except for one case. Although the K-value estimation technology should be improved for more accurate body temperature estimation, the results of finite element simulation showed that bi-medium deep body thermometer could accurately measure various tissue temperatures under diverse environments.

Flow Structure Interaction 3-D Reciprocating Compressor and Impact Analyses of Compressor Discharge Valve (압축기 토출벨브의 유체-구조 연계해석 및 충돌해석)

  • Octavianty, Ressa;Kim, Dong-Hyun;Park, Kang-Gyun;Jung, Won-Hyun;Ahn, Jae-Woo;Moon, Kyeong-Ho;Ko, Young-Pil;Kim, Hyeong-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.633-640
    • /
    • 2007
  • In this paper, 3-D reciprocating compressor is taken into flow-structure interaction analysis. The full cycle process consisted of cylinder expansion and compression has been modeled without considering flow leakage through cylinder wall. Fully-coupled FSI analysis of this compressor model was iteratively solved and gives sufficient result with the experimental test. The study is emphasized to thoroughly investigate discharge valve motion, opening and closing, in order to determine discharge valve region which is prone to have high effective stress. The cylinder pressure is successfully validated before conducting impact analyses between discharge valve and other susceptible supported structure. Velocity profile has been obtained in FSI analysis is used as initial condition to carry out further impact analyses. Stress result of discharge valve and valve spring gives preliminary estimation of higher stress area due to its impact phenomena.

  • PDF

An Experimental Study on the Estimation of Wind Force Coefficient of Floating Type Photovoltaic Energy Generation System (수상 태양광발전 시스템의 풍력계수 산정에 관한 실험적 연구)

  • Lee, Young-Geun;Lee, Nam-Hyung;Joo, Hyung-Joong;Yoon, Soon-Jong
    • New & Renewable Energy
    • /
    • v.9 no.1
    • /
    • pp.60-68
    • /
    • 2013
  • In recent years, green house effect related natural disasters occur throughout the world. Carbon dioxide, mainly comes from the fossil fuel burning, is suspected to be the cause of green house effect. To reduce the emission of carbon dioxide, we need to find alternative energy resources such as photovoltaic energy. In this paper, the basic characteristics of wind force coefficient on a PV panel installed on the floating type PV energy generation system are investigated though the two-dimensional wind tunnel tests. Test variables included the angle of PV panel, direction of wind, number of rows of PV panel and attached or not attached frame. Based on the results obtained through the wind tunnel tests, it was found that the wind force coefficient can be used as a preliminary data in the design of the structure.

GIS-supported Evaluation System for Road Traffic-related Air Pollution (도로교통관련 대기오염평가 GIS지원시스템)

  • Pior, Myoung-Young
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.8 no.1 s.15
    • /
    • pp.13-25
    • /
    • 2000
  • Road traffic-related environment problems has become now serious problem common in the urban life throughout the world. In this study, a GIS-supported evaluation system has been developed for dealing with the road traffic-related environment problems, especially focusing on air Pollution in the urban areas. The developed system consists lof three essential parts: GIS; traffic-related air pollution simulation model; and the database for potential strategies. In establishing the simulation model, a GIS-supported environment can provide a useful tool for handling a wide range of data characterizing study areas and for preparing more accurate estimation on real locations. Such roles of the GIS-supported system can be helpful to more efficient analysis and more reasonable decision-makings. As a preliminary stage in developing the system, the metropolitan area of Cairo in Egypt was applying into being as a Pilot study to test the Potentiality of the prototype system.

  • PDF

Analysis of the Aerodynamic Characteristics of Missile Configurations Using a Semi-Empirical Method (Semi-Empirical 기법을 이용한 미사일 형상의 공력특성 해석)

  • Han, Myung-Shin;Myong, Rho-Shin;Cho, Tae-Hwan;Hwang, Jong-Son;Park, Chan-Hyeok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.26-31
    • /
    • 2005
  • An efficient estimation of the aerodynamic characteristics for missile configurations is essential in the preliminary stage of a missile design. In this study, a Missile DATCOM family code based on the semi-empirical method was utilized for this purpose. In order to check the accuracy and reliability of the code several test cases have been considered: subsonic flow with high angles of attack and supersonic flow with moderate angles of attack. It turned out that the code in general provides prediction in qualitative agreement with the experimental data and results by other works. Finally, the code was applied to a more complicated missile configuration with canard and freely spinning tail fin.

Development of Hard-wired Instrumentation and Control for the Neutral Beam Test Facility at KAERI

  • Jung Ki-Sok;Yoon Byung-Joo;Yoon Jae-Sung;Seo Min-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.359-365
    • /
    • 2006
  • Since the start of the KSTAR (Korea Superconducting Tokamak Advanced Research) project, Instrumentation and Control (I&C) of the Neutral Beam Test Facility (NB-TF) has been striving to answer diverse requests arising from various facets during the project's development and construction phases. Hard-wired electrical circuits have been designed, tested, fabricated, and finally installed to the relevant parts of the system. In relation to the vacuum system I&C, controlling functions for the rotary pumps, a Roots pump, two turbomolecular pumps, and four cryosorption pumps have been constructed. I&C for the ion source operation are the temperature and flow rate signal monitoring, Langmuir probe signal measurements, gradient grid current measurements, and arc detector circuit. For the huge power system to be monitored or safely operated, many temperature measurement functions have also been implemented for the beam line components like the neutralizer, bending magnet, ion dump, and calorimeter. Nearly all of the control and probe signals between the NB test stand and the control room were made to be transmitted through the optical cables. Failures of coolant flow or beam line vacuum pressure were made to be safely blocked from influencing the system by an appropriate interlock circuit that will shut down the extraction voltage application to the system or prevent damages to the vacuum components. Preliminary estimation of the beam power through the calorimetric measurement shows that 87.9% of the total power of the 60kV/18A beam with 200 seconds duration is absorbed by the calorimeter surface. Most of these I&C results would be highly appropriate for the construction of the main NBI facility for the KSTAR national fusion research project.

Experimental evaluation of an inertial mass damper and its analytical model for cable vibration mitigation

  • Lu, Lei;Fermandois, Gaston A.;Lu, Xilin;Spencer, Billie F. Jr.;Duan, Yuan-Feng;Zhou, Ying
    • Smart Structures and Systems
    • /
    • v.23 no.6
    • /
    • pp.589-613
    • /
    • 2019
  • Cables are prone to vibration due to their low inherent damping characteristics. Recently, negative stiffness dampers have gained attentions, because of their promising energy dissipation ability. The viscous inertial mass damper (termed as VIMD hereinafter) can be viewed as one realization of the inerter. It is formed by paralleling an inertial mass part with a common energy dissipation element (e.g., viscous element) and able to provide pseudo-negative stiffness properties to flexible systems such as cables. A previous study examined the potential of IMD to enhance the damping of stay cables. Because there are already models for common energy dissipation elements, the key to establish a general model for IMD is to propose an analytical model of the rotary mass component. In this paper, the characteristics of the rotary mass and the proposed analytical model have been evaluated by the numerical and experimental tests. First, a series of harmonic tests are conducted to show the performance and properties of the IMD only having the rotary mass. Then, the mechanism of nonlinearities is analyzed, and an analytical model is introduced and validated by comparing with the experimental data. Finally, a real-time hybrid simulation test is conducted with a physical IMD specimen and cable numerical substructure under distributed sinusoidal excitation. The results show that the chosen model of the rotary mass part can provide better estimation on the damper's performance, and it is better to use it to form a general analytical model of IMD. On the other hand, the simplified damper model is accurate for the preliminary simulation of the cable responses.

A Critical Evaluation of Dichotomous Choice Responses in Contingent Valuation Method (양분선택형 조건부가치측정법 응답자료의 실증적 쟁점분석)

  • Eom, Young Sook
    • Environmental and Resource Economics Review
    • /
    • v.20 no.1
    • /
    • pp.119-153
    • /
    • 2011
  • This study reviews various aspects of model formulating processes of dichotomous choice responses of the contingent valuation method (CVM), which has been increasingly used in the preliminary feasibility test of Korea public investment projects. The theoretical review emphasizes the consistency between WTP estimation process and WTP measurement process. The empirical analysis suggests that two common parametric models for dichotmous choice responses (RUM and RWTP) and two commonly used probability distributions of random components (probit and logit) resulted in all most the same empirical WTP distributions, as long as the WTP functions are specified to be a linear function of the bid amounts. However, the efficiency gain of DB response compared to SB response were supported on the ground that the two CV responses are derived from the same WTP distribution. Moreover for the exponential WTP function which guarantees the non-negative WTP measures, sample mean WTP were quite different from median WTP if the scale parameter of WTP function turned out to be large.

  • PDF

Automatic Parameter Estimation of Hydrogeologic Field Test around Underground Storage Caverns by using Nonlinear Regression Model (비선형 회귀모형을 이용한 지하저장공동 주변 현장수리지질시험 매개변수의 자동 추정)

  • Chung, Il-Moon;Cho, Won-Cheol;Kim, Nam-Won
    • The Journal of Engineering Geology
    • /
    • v.18 no.4
    • /
    • pp.359-369
    • /
    • 2008
  • For the design and effective management of underground storage caverns, preliminary investigation on the hydrogeologic parameters around caverns and analysis on the groundwater flow must be carried out. The data collection is very imporatnat task for the hydrogeologic design so various hydraulic tests have been performed. When analyzing the injection/fall off test data, existing graphical method to estimate the parameters in Theis' equation is widely used. However this method has some sources of error when estimating parameters by means of human faults. Therefore the method of estimating parameters by means of statistical methods such as regression type is evaluated as a useful tool. In this study, nonlinear regression analysis for the Theis' equation is suggested and applied to the estimation of parameters for the real field interference data around underground storage caverns. Damping parameter which reduce the iteration numbers and inhance the convergence is also introduced.