• Title/Summary/Keyword: predilution

Search Result 2, Processing Time 0.016 seconds

Estimation of Urea and Vitamin B12 Concentrations in the Body using Two Compartment Model (신 부전증 환자의 요소 및 비타민 B12 의 체내농도 추정)

  • 장호남;박한철
    • Journal of Biomedical Engineering Research
    • /
    • v.3 no.1
    • /
    • pp.9-16
    • /
    • 1982
  • Removal of urea and vitamin B12 was simulated using two pool models with closed loop dialysis, open loop dialysis, and hemodiafiltrations with predilution and postdilulion. It was found that urea removal was limited by dialyzer clearance, however B12 removal was limited both by the resistance between ECF and ICF and by dialyzer clearance. Open loop dialysis was better than closed loop dialysis in terms of dialysate requirement and removal efficiency. Residual renal function plays an important role in removing vitamin B12. Dialysis frequency more than twice/wide does not have great effect on removal efficiency, but has the effect of reducing the difference between maximum and minimum cancentrations during dialysis period.

  • PDF

The Predilution Effect of Al-based Liquid Coagulants for the Optimal Efficacy (최적 응집 효율을 위한 Al계 액상 응집제의 희석 효과)

  • Heo, Jae-Yong;Lee, Sang-Wha
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • The coagulation efficacy of Al-based coagulants (such as Alum, PACS, and PACC) was investigated to ascertain removal efficiencies of turbidity and phosphate with variation of solution pH, coagulant dosages, and pre-dilution ratios. The efficacy of Al-based coagulants was maximized in the pH range of 6~9. Under the initial condition of pH 8, $10mg/L\;{PO_4}^{3-}$, and 20 NTU, Al-based coagulants exhibited a similar efficacy in the removal of turbidity, whereas the removal efficiency of phosphate was clearly dependent on the basicity of coagulants: Alum (0%) > PACS (45~50%) > PACC (70%). At high initial turbidity of 100 NTU, polymeric coagulants, such as PACS and PACC, exhibited a higher removal efficiency of turbidity compared to Alum. In comparison to direct injection of coagulants at low initial turbidity (20 NTU), 500~2000 times pre-diluted Alum, exhibited reduced coagulation efficacy; however, removal efficiencies of turbidity and phosphate increased with the increase of retention time. Pres-diluted PACC exhibited the enhanced coagulation efficacy followed by silght decrease of the removal efficiencies with increase of the retention time. At high initial turbidity of 100 NTU, pre-diluted Alum and PACC exhibited higher removal efficiencies of turbidity and phosphate.