• Title/Summary/Keyword: precast buildings

Search Result 115, Processing Time 0.024 seconds

Rapid seismic performance assessment method for one story hinged precast buildings

  • Palanci, Mehmet;Senel, Sevket Murat
    • Structural Engineering and Mechanics
    • /
    • v.48 no.2
    • /
    • pp.257-274
    • /
    • 2013
  • In this study, seismic performance of one story hinged precast buildings, which represents the majority of existing lightweight industrial building stock of Turkey, was assessed. A lot of precast buildings, constructed in one of the important seismic zones of western Turkey, were investigated and building inventories were prepared. By this method, structural properties of inventory buildings and damaged precast buildings in recent earthquakes were compared. Damage estimations based on nonlinear analysis methods have shown that estimated damage levels of inventory buildings and observed damage levels in recent earthquakes are similar. Accuracy of damage estimation study and the simplicity of the one story precast building models implied that rapid seismic performance assessment method for these buildings can be developed. In this assessment method, capacity curves and vibration periods of precast buildings were calculated by using structural properties of precast buildings. The proposed assessment method was applied to inventory buildings by using two different seismic demand scenarios which reflect moderate and soft soil conditions. Comparison of detailed analysis and rapid assessment methods have indicated that reliable seismic performance estimations can be performed by using proposed method. It is also observed that distribution of damage estimations is compatible in both scenarios.

Fragility based damage assesment in existing precast industrial buildings: A case study for Turkey

  • Senel, Sevket Murat;Kayhan, Ali Haydar
    • Structural Engineering and Mechanics
    • /
    • v.34 no.1
    • /
    • pp.39-60
    • /
    • 2010
  • In Turkey, majority of industrial facilities are composed of precast buildings. However, precast buildings have suffered extensive damage during Kocaeli and Duzce (1999) and Adana-Ceyhan (1998) earthquakes. Therefore, in this study, fragilities of existing building stock and damage probabilities of precast buildings were studied. For this purpose, building inventories were prepared and variation of structural parameters was determined by investigating the design project of 65 precast buildings constructed in Denizli, Turkey. Twelve analysis models which reflect the stiffness, strength and ductility properties of building inventory were constructed. After the definition of strain based displacement limits and corresponding damage states for buildings, displacement demands were calculated by using non linear time history analysis. During the analyses 360 strong ground motion records were used. Exceedence ratios of concerned damage limits was calculated by checking the displacement demands and then PGV based fragility curves were constructed. Efficiency of strength, stiffness and ductility properties of existing precast buildings were investigated by comparing the fragility curves. The results have shown that the most effective parameters that govern the damage probabilities of precast buildings are stiffness and ductility. It was also stated that the results of fragility analysis and damage and failure observations performed after Kocaeli and Duzce Earthquakes are compatible.

Verification of diaphragm seismic design factors for precast concrete office buildings

  • Zhang, Dichuan;Fleischman, Robert B.;Lee, Deuckhang
    • Earthquakes and Structures
    • /
    • v.20 no.1
    • /
    • pp.13-27
    • /
    • 2021
  • A new seismic design methodology has been developed for precast concrete diaphragms. Seismic design factors were used to be applied on top of diaphragm seismic design forces in the current code. These factors, established through extensive parametric studies, align diaphragm design strengths with different seismic performance targets. A simplified evaluation structure with a single-bay plan was used in the parametric studies. This simplified evaluation structure is reasonable and cost-effective as it can comprehensively cover structural geometries and design parameters. However, further verification and investigation are required to apply these design factors to prototype structures with realistic layouts. This paper presents diaphragm design of several precast concrete office buildings using the new design methodology. The applicability of the design factor to the office building was evaluated and verified through nonlinear time history analyses. The seismic behavior and performance of the diaphragm were investigated for the precast concrete office buildings. It was found that the design factor established for the new design methodology is applicable to the realistic precast concrete office buildings.

Deformation Demand of the Precast Concrete Frame Buildings with Ductile Connection in Moderate Seismic Regions (연성적인 접합부를 가진 프리캐스트 콘크리트 골조건물의 변형수요)

  • 서수연;이리형
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.89-98
    • /
    • 1999
  • This paper evaluates nonlinear response characteristics of precast concrete frame buildings. where plastics hinging occurs in the precast connection. Designs were developed for buildings of 5, 10 and 15 stories in hight for moderate seismic risk regions of the U. S. The responses of the buildings were analyzed using DRAIN-2DX and following Nonlinear static analysis procedure of ATC 19. The main variables of the analyses were the strength and stiffness of the connection. Also, for the analysis, the bi-linear response model, developed and inserted into the DRAIN-2DX program by Shan Shi and D. Fouch, was used. With the results of analysis, the deformation demands of the connection of precast concrete frame buildings are proposed by using equal-dissipated energy capacity. It was shown that the strength of the buildings as well as their displacement capacities decreased with the decrease of either the strength or stiffness in the connections. Therefore such changes also require reductions in the response modification factors for such buildings. However, if the precast concrete frame building has plastic hinging in the connection, and has a more ductile connection than the monolithic frame building, then no reduction in R may be necessary. The deformation demand required of the connection to achieve that condition is evaluated and a simple relation is suggested in the paper.

Design Considerations of Connections in High-Rise P.C. Apartments (고층 P.C 아파트의 접합부 설계)

  • 정하선;김두영
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1989.10a
    • /
    • pp.59-62
    • /
    • 1989
  • Construction of high-rise precast concrete apartment is an atractive alternative solution for severe shortage of residential facilities, especially in metropolitan areas in Korea. New building regulations enforced since 1988 requires all buildings higher than 6 storeys to be designed for earthquake. However, we hardly have any experience on seismic design of precast concrete buildings. This paper deals with methodology of seismic design and design considerations of connections for the large panel structures. Also addressed in this paper are studies needed to develop proper seismic design procedures of precast concrete buildings.

  • PDF

Absolute Comparison of Construction Periods between Precast Concrete and Reinforced Concrete Apartment Buildings (PC 및 RC공동주택 골조공사에 대한 공사기간 절대비교)

  • Kim, Ki-Ho;Lee, Bum-Sik;Kim, Jin-Won;Kim, Yeon-Ho;Lee, Dong-Gun;Sohn, Jeong-Rak
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.293-294
    • /
    • 2023
  • In accordance with recent changes in construction trends, interest in introducing the OSC, such as the Precast Concrete, is increasing in apartment buildings. In domestic studies, studies on the prediction of the construction period of PC apartment buildings through simulation have been conducted, but there is no study on the comparison of the construction period according to the actual construction of Precast Concrete(PC) and Reinforced Concrete(RC). Therefore, this study seeks to grasp the technology of the current PC construction method and to secure the original technology of project management through comparison of the absolute time of frame construction for PC and RC buildings composed of the same plane.

  • PDF

In-situ Production Analysis of Composite Precast Concrete Members of Green Frame

  • Lim, Chae-Yeon;Joo, Jin-Kyu;Lee, Goon-Jae;Kim, Sun-Kuk
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.501-514
    • /
    • 2011
  • Recently, there have been many cases in which the difficulty of repair and replacement of principal elements in the bearing wall structure for apartment buildings, which is a major part of apartment buildings in Korea, has led to the reconstruction of buildings rather than their remodeling. To address this problem, the Korea government now allows a floor area ratio of up to 20 %, and has relaxed the building height limits to encourage the use of a rahmen structure instead of a bearing wall structure. However, since reinforced concrete rahmen structures have many problems, including higher floor height and greater construction cost, a great deal of research into rahmen composite precast concrete structures have been conducted. Green Frame, one of the developed prototypes, is expected to provide economic benefits through in-situ production for precast concrete column and beam. For in-situ production of composite precast concrete members, a detailed plan for production, curing, and installation is needed. However, it needs to be confirmed that the space is sufficient to produce the precast concrete members on-site before planning those activities. Therefore, this study proposes in-situ production analysis of composite precast concrete members of Green Frame with the evaluation of structural safety and available area on the parking structure. The result of this study shows that the in-situ production of precast concrete members is possible through a case study.

Seismic performance assessment of the precast concrete buildings using FEMA P-695 methodology

  • Adibi, Mahdi;Talebkhah, Roozbeh
    • Structural Engineering and Mechanics
    • /
    • v.82 no.1
    • /
    • pp.55-67
    • /
    • 2022
  • The precast reinforced concrete frame system is a method for industrialization of construction. However, the seismic performance factor of this structural system is not explicitly clarified in some existing building codes. In this paper, the seismic performance factor for the existing precast concrete building frame systems with cast-in-situ reinforced shear walls were evaluated. Nonlinear behavior of the precast beam-column joints and cast-in-situ reinforced shear walls were considered in the modeling of the structures. The ATC-19's coefficient method was used for calculating the seismic performance factor and the FEMA P-695's approach was adopted for evaluating the accuracy of the computed seismic performance factor. The results showed that the over-strength factor varies from 2 to 2.63 and the seismic performance factor (R factor) varies from 5.1 to 8.95 concerning the height of the structure. Also, it was proved that all of the examined buildings have adequate safety against the collapse at the MCE level of earthquake, so the validity of R factors was confirmed. The obtained incremental dynamic analysis (IDA) results indicated that the minimum adjusted collapse margin ratio (ACMR) of the precast buildings representing the seismic vulnerability of the structures approximately equaled to 2.7, and pass the requirements of FEMA P-695.

Observational failure analysis of precast buildings after the 2012 Emilia earthquakes

  • Minghini, Fabio;Ongaretto, Elena;Ligabue, Veronica;Savoia, Marco;Tullini, Nerio
    • Earthquakes and Structures
    • /
    • v.11 no.2
    • /
    • pp.327-346
    • /
    • 2016
  • The 2012 Emilia (Italy) earthquakes struck a highly industrialized area including several thousands of industrial prefabricated buildings. Due to the lack of specific design and detailing for earthquake resistance, precast reinforced concrete (RC) buildings suffered from severe damages and even partial or total collapses in many cases. The present study reports a data inventory of damages from field survey on prefabricated buildings. The damage database concerns more than 1400 buildings (about 30% of the total precast building stock in the struck region). Making use of the available shakemaps of the two mainshocks, damage distributions were related with distance from the nearest epicentre and corresponding Pseudo-Spectral Acceleration for a period of 1 second (PSA at 1 s) or Peak Ground Acceleration (PGA). It was found that about 90% of the severely damaged to collapsed buildings included into the database stay within 16 km from the epicentre and experienced a PSA larger than 0.12 g. Moreover, 90% of slightly to moderately damaged buildings are located at less than 25 km from the epicentre and were affected by a PSA larger than 0.06 g. Nevertheless, the undamaged buildings examined are almost uniformly distributed over the struck region and 10% of them suffered a PSA not lower than 0.19g. The damage distributions in terms of the maximum experienced PGA show a sudden increase for $PGA{\geq}0.28g$. In this PGA interval, 442 buildings were collected in the database; 55% of them suffered severe damages up to collapse, 32% reported slight to moderate damages, whereas the remaining 13% resulted undamaged.

Nonlinear finite element modelling of centric dowel connections in precast buildings

  • Zoubek, Blaz;Fahjan, Yasin;Fischinger, Matej;Isakovic, Tatjana
    • Computers and Concrete
    • /
    • v.14 no.4
    • /
    • pp.463-477
    • /
    • 2014
  • The modelling approach in the case of connections in precast buildings is specific. The assembly of the constitutive parts of the connection requires the inclusion of contact definitions in the model. In addition, the material non-linearity including the influence of the spatial stress distribution should be taken into account where appropriate. Here a complex model of a beam-to-column dowel connection is presented. Experiments on the analysed connection were performed within the framework of the European project SAFECAST (Performance of Innovative Mechanical Connections in Precast Building Structures under Seismic Conditions). Several material and interaction parameters were investigated and the influence of each of them was evaluated. The set of parameters which gave the best match with the experiments was chosen.