• 제목/요약/키워드: pre-stressed concrete

검색결과 83건 처리시간 0.028초

Nonlinear shear strength of pre-stressed concrete beams

  • Rahai, Alireza;Shokoohfar, A.
    • Structural Engineering and Mechanics
    • /
    • 제41권4호
    • /
    • pp.441-458
    • /
    • 2012
  • The shear strength is an important factor in the design of prestressed concrete beams. Therefore, researchers have utilized various methods to determine the shear strength of these elements for the design purposes. To evaluate some of the proposed theoretical methods, numerous models of post-tensioned beams with or without vertical prestressing are selected and analyzed using the finite element method and assuming nonlinear behavior for the materials. In this regard the validity of modeling is evaluated based on some tests results. In the second part of the study two beam specimens are built and tested and their load-deformation curve and cracking pattern are studied. The analytical results consist of compressive strut slope and mid span load deflection are compared with some experimental results, and the results of some codes' formulas. Finally comparing the results of nonlinear analysis with the experimental values, a new formula is proposed for determining strut slopes in prestressed concrete beams.

Modelling and integrity assessment of shear connectors in precast cast-in-situ concrete bridges

  • Moyo, Pilate;Sibanda, Bongani;Beushausen, Hans
    • Structural Engineering and Mechanics
    • /
    • 제42권1호
    • /
    • pp.55-72
    • /
    • 2012
  • Precast-cast insitu concrete bridge construction is widely practiced for small to medium span structures. These bridges consist of precast pre-stressed concrete beams of various cross-sections with a cast in-situ reinforced concrete slab. The connection between the beams and the slab is via shear links often included during the manufacturing process of the beams. This form of construction is attractive as it provides for standardisation, reduced formwork and construction time. The assessment of the integrity of shear connectors in existing bridges is a major challenge. A procedure for assessment of shear connectors based on vibration testing and finite element model updating is proposed. The technique is applied successfully to a scaled model bridge model and an existing bridge structure.

A Case Study on the Assessment of Damaged Cause for the Damaged Reinforced Concrete Pier

  • Chai, Won-Kyu;Kim, Kwang-Il;Son, Young-Hyun
    • International Journal of Safety
    • /
    • 제10권1호
    • /
    • pp.16-21
    • /
    • 2011
  • In this thesis, appearance inspection, compressive strength of concrete test, arrangement of bar inspection, survey, and bearing stress analysis were performed on a damaged coping of reinforced concrete pier to investigate the damage cause. According to the performed a series of inspections, it was found that the coping of pier was damaged during PSC (Pre-stressed Concrete) beam construction. In this thesis, the repair method for damaged pier was studied. The repair procedure used in this thesis was follows : chipping for damaged part, clean by high-pressure, installation of wire mesh, coating of surface hardening, construction of section restoration material, copula grinding, and prevent coating for far-infrared radiation.

  • PDF

Effect of ground granulated blast furnace slag on time-dependent tensile strength of concrete

  • Shariq, M.;Prasad, J.
    • Computers and Concrete
    • /
    • 제23권2호
    • /
    • pp.133-143
    • /
    • 2019
  • The paper presents the experimental investigations into the effect of ground granulated blast furnace slag (GGBFS) on the time-dependent tensile strength of concrete. The splitting and flexural tensile strength of concrete was determined at the ages of 3, 7, 28, 56, 90, 150 and 180 days using the cylindrical and prism specimens respectively for plain and GGBFS concrete. The amount of cement replacement by GGBFS was 0%, 40% and 60% on the weight basis. The maximum curing age was kept as 28 days. The results showed that the splitting and flexural tensile strength of concrete containing GGBFS has been found lower than the plain concrete at all ages and for all mixes. The tensile strength of 40 percent replacement has been found higher than the 60 percent at all ages and for all mixes. The rate of gain of splitting and flexural tensile strength of 40 percent GGBFS concrete is found higher than the plain concrete and 60 percent GGBFS concrete at the ages varying from 28 to 180 days. The experimental results of time-dependent tensile strength of concrete are compared with the available models. New models for the prediction of time-dependent splitting and flexural tensile strength of concrete containing GGBFS are proposed. The present experimental and analytical study will be helpful for the designers to know the time-dependent tensile properties of GGBFS concrete to meet the design requirements of liquid retaining reinforced and pre-stressed concrete structures.

신형식 거더의 고강도 콘크리트 적용 시 비선형 거동 분석 (Non-linear Behavior of New Type Girder Filled by High-Strength Concrete)

  • 최성우;이학;공정식
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.217-220
    • /
    • 2008
  • 구조물의 시공에 있어 더욱 경제적이고 안정적인 결과를 얻기 위해 최근 전 세계적으로 고성능 콘크리트와 복합재료에 관한 연구가 활발히 이루어지고 있다. 그 중 하나로 대구경의 강관 내부를 콘크리트계 재료로 충전하여 충전재간의 상호 구속효과(Confinement effect)로 인해 부재의 변형성능과 강성 및 내력을 향상시키는 콘크리트 충전 강관구조(Concrete Filled Steel Tubular Structure, CFT구조)에 아치구조 효과와 강선 등을 이용한 프리스트레스 구조를 도입하여, 구조적, 경제적 효율성을 극대화 시킨 새로운 형식의 거더인 CFTA 거더(Concrete Filled and Tied Steel Tubular Arch 거더)가 있다. 본 연구에서는 구조해석 프로그램인 ABAQUS 6.5-1을 사용하여 CFTA 거더에 일반 콘크리트와 여러 강도의 고강도 콘크리트를 충전한 모델의 비선형 거동을 분석하고 각각의 결과를 비교 분석하였다.

  • PDF

Chloride penetration in anchorage concrete of suspension bridge during construction stage

  • Yang, In-Hwan;Yoon, Yong-Sik;Kwon, Seung-Jun
    • Advances in concrete construction
    • /
    • 제10권1호
    • /
    • pp.13-20
    • /
    • 2020
  • Steel corrosion in embedded steel causes a significant durability problems and this usually propagates to structural degradation. Large-scaled concrete structures, PSC (Pre-stressed Concrete) or RC (Reinforced Concrete) structures, are usually constructed with mass concrete and require quite a long construction period. When they are located near to sea shore, chloride ion penetrates into concrete through direct or indirect exposure to marine environment, and this leads durability problems. Even if the structures are sheltered from chloride ingress outside after construction, the chloride contents which have been penetrated into concrete during the long construction period are differently evaluated from the initially mixed chloride content. In the study, chloride profiles in cores extracted from anchorage concrete block in two large-scaled suspension bridge (K and P structure) are evaluated considering the exposure periods and conditions. Total 21 cores in tendon room and chamber room were obtained, and the acid-soluble chlorides and compressive strength were evaluated for the structures containing construction period around 3 years. The test results like diffusion coefficient and surface chloride content from the construction joint and cracked area were also discussed with the considerations for maintenance.

Experimental research on vertical mechanical performance of embedded through-penetrating steel-concrete composite joint in high-temperature gas-cooled reactor pebble-bed module

  • Zhang, Peiyao;Guo, Quanquan;Pang, Sen;Sun, Yunlun;Chen, Yan
    • Nuclear Engineering and Technology
    • /
    • 제54권1호
    • /
    • pp.357-373
    • /
    • 2022
  • The high-temperature gas-cooled reactor pebble-bed module project is the first commercial Generation-IV NPP(Nuclear Power Plant) in China. A new joint is used for the vertical support of RPV(Reactor Pressure Vessel). The steel corbel is integrally embedded into the reactor-cabin wall through eight asymmetrically arranged pre-stressed high-strength bolts, achieving the different path transmission of shear force and moment. The vertical monotonic loading test of two specimens is conducted. The results show that the failure mode of the joint is bolt fracture. There is no prominent yield stage in the whole loading process. The stress of bolts is linearly distributed along the height of corbel at initial loading. As the load increases, the height of neutral axis of bolts gradually decreases. The upper and lower edges of the wall opening contact the corbel plate to restrict the rotation of the corbel. During the loading, the pre-stress of some bolts decreases. The increase of the pre-stress strength ratio of bolts has no noticeable effect on the structure stiffness, but it reduces the ultimate bearing capacity of the joint. A simplified calculation model for the elastic stage of the joint is established, and the estimation results are in good agreement with the experimental results.

인천국제공항 여객터미널 전면 고가 교량 공사 시공방법 및 수화열 대책 (Construction Method and Control System of the Heat of Hydration for Inchon International Airport Elevated Road Way)

  • 임채만;박명웅;조용기;조선규;김은겸
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.869-881
    • /
    • 1999
  • Inchon International Airport Elevated Road Way is located between the Passenger Terminal Building and Transportaion Center which are Inchon International Airport core construction projects. The deck of the bridge is consists of 5-span or 6-span continuous pre-stressed concrete slab. Steel form has been used to enhance the quality of texture on concrete slab. Steel form has been used to enhance the quality of texture on concrete surface, lower surface of deck slab with the two way arch has been manufactured by highly professional manner in order to get an beautiful exterior architectural looks. The prestressed concrete deck slab is mass concrete structures with a high-specified concrete strength and a varying section in the range of 0.95-2.8m thickness. Therefore high risks of thermal cracking occurrence by heat of hydration highly are expected. To resolve such problem, we adopted type 1 cement and pipe cooking method at construction site through mass concrete specimen test and 3-dimensional analysis. For Pipe cooling we used 25mm diameter stainless pipes with wrinkles. Cooling pipe with spacing 50-60cm has been installed. And continuous pipe cooling with cooling water of 15$^{\circ}C$ was conducted for 2days. In present 8 span of all 29 spans construction has been completed. No thermal cracking heat hydration has been observed yet.

  • PDF

PSC 일체식 교대교량의 거동특성에 관한 매개변수 연구 (Parametric Study on the Behavioral Characteristics of PSC Integral Abutment Bridges)

  • 최우진;윤지현;안진희;김상효;이상우
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.31-32
    • /
    • 2009
  • 본 연구는 Pre-Stressed Concrete 일체식 교대교량의 거동을 평가하기 위한 매개변수 연구로써, 매개변수 변화에 따른 거동 특성을 단경간 및 다경간 PSC 교량의 상부구조에 작용하는 모멘트 변화 경향을 이용하여 분석하였다.

  • PDF

Shear lag effects on wide U-section pre-stressed concrete light rail bridges

  • Boules, Philopateer F.;Mehanny, Sameh S.F.;Bakhoum, Mourad M.
    • Structural Engineering and Mechanics
    • /
    • 제68권1호
    • /
    • pp.67-80
    • /
    • 2018
  • Recently, U-section decks have been more and more used in metro and light rail bridges as an innovative concept in bridge deck design and a successful alternative to conventional box girders because of their potential advantages. U-section may be viewed as a single vent box girder eliminating the top slab connecting the webs, with the moving vehicles travelling on the lower deck. U-section bridges thus solve many problems like limited vertical clearance underneath the bridge lowest point, besides providing built-in noise barriers. Beam theory in mechanics assumes that plane section remains plane after bending, but it was found that shearing forces produce shear deformations and the plane section does not remain plane. This phenomenon leads to distortion of the cross section. For a box or a U section, this distortion makes the central part of the slab lagging behind those parts closer to the webs and this is known as shear lag effect. A sample real-world double-track U-section metro bridge is modelled in this paper using a commercial finite element analysis program and is analysed under various loading conditions and for different geometric variations. The three-dimensional finite element analysis is used to demonstrate variations in the transverse bending moments in the deck as well as variations in the longitudinal normal stresses induced in the cross section along the U-girder's span thus capturing warping and shear lag effects which are then compared to the stresses calculated using conventional beam theory. This comparison is performed not only to locate the distortion, warping and shear lag effects typically induced in U-section bridges but also to assess the main parameters influencing them the most.