• Title/Summary/Keyword: practically

Search Result 2,907, Processing Time 0.037 seconds

Output LC Filter Design of Three Phase Voltage Source Inverter Considering the Performance of Controller (제어기 응답을 고려한 삼상 전압형 인버터의 출력 LC필터 설계)

  • 최재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.748-751
    • /
    • 2000
  • in this paper the design procedure of three phase voltage source inverter output filter is described. The 'd' axis transfer function of the filter output voltage to the load current is described with the capacitor value and the system time constant including the controller. This means that the relation between the filter capacitor value and the system time constant is given as the closed form. By using the above closed form the capacitor value can be calculated with the system time constant is given as the closed,. form the capacitor value can be calculated with the system time constant which can be implemented practically not using the try and error method. And as the effect of the load is connected.

  • PDF

A study on the Push-Pull type high frequency resonant inverter (푸시-풀형 고주파 공진 인버터에 관한 연구)

  • 서철식
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.364-367
    • /
    • 2000
  • This paper describes a Push-Pull type high fre-quency resonant inverter conposed of consolidation of boost converter circuit and resonant circuit. By using a boost converter circuit the proposed inverter can obtain a twice input voltage of reson ant circuit and reduce a secondary turn ratios. By using both boost-converter and switching device can be reduce by half. Also the ana-lysis of the proposed circuit was described by using normalized parameter and operating characteristics have been evaluated as to switching frequency and parameters. In the future this pro-posed inverter shows that it can be practically used as a power source system for the lighting equipment of discharge lamp induction heating applications.

  • PDF

Precise Speed Control and Sensorless Technique of PM BLDC Motor Using the PLL Algorithm (PM BLDC 모터의 PLL 알고리즘을 사용한 정밀속도제어 및 센서리스 기법)

  • Lee, Seung-Jun;Yoon, Yong-Ho;Kim, Young-Ran;Won, Chung-Yuen;Choi, You-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.449-454
    • /
    • 2005
  • Brushless DC Motor(PM BLDCM) is widely used in industrial applications due to its high efficiency and power density. In order to increase reliability and reduce system cost, this paper studies particularly applicable method for sensorless PM BLDCM drive system. The resulting third harmonic signal keeps a constant phase relationship with the rotor flux for any motor speed and load condition, and is practically free of noise that can be introduced by the inverter switching, making this a robust sensing method. As a result, the method described here is not sensitive to filtering delays, allowing the motor to achieve a good performance over a wide speed range. In addition, a simple starting method and a speed estimation approach are also proposed.

  • PDF

A Study On Sing1e-Stage Active-Clamp Type High Frequency Resonant Inverter (단일 전력단 능동 클램프형 고주파 공전 인버터에 관한 연구)

  • 강진욱;원재선;김동희;조규판;김경식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.287-291
    • /
    • 2002
  • This paper presents active-clamp class-E high frequency resonant inverter with single-stage. The proposed circuit is integrated active-clamp class-E circuit to boost converter with the function of power factor correction. Boost converter is operated in positive and negative half cycle respectively at line frequency(60Hz), Such a operating in discontinuous conduction mode(DCM) of boost converter performs high power factor. By adding active-clamp circuit in class-E inverter, main switch of inverter part is operated not only ZVS(Zero Voltage Switch) but also reduced the switching voltage stress of main switch. This paper shows that simulation result using Psim 4.1 prove the validity of theoretical analysis. This proposed inverter will be able to be practically used as a power supply in various fields as induction heating applications, DC-DC converter etc.

  • PDF

Characteristics Analysis of Instantaneous Current Resultant Type Load Parallel High Frequency Resonant Inverter (순시전류합성형 부하병렬 고주파 공진 인버터의 특성해석)

  • 조규판;원재선;이봉섭;심광렬;배영호
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.293-296
    • /
    • 2002
  • This paper describes the instantaneous current resultant type load parallel high frequency resonant inverter consisting of three unit half-bridge serial and parallel resonant inverter can be used as power source of induction heating. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, the principle of basic operating and the its characteristics are estimated by the parameters such as switching frequency($\mu$), load resistance(λ). Experimental results are presented to verify theoretical discussion. This proposed inverter will can be practically used as a power supply in various fields as induction heating application, DC-DC converter etc.

  • PDF

Practically Secure and Efficient Random Bit Generator Using Digital Fingerprint Image for The Source of Random (디지털 지문 이미지를 잡음원으로 사용하는 안전하고 효율적인 난수 생성기)

  • Park, Seung-Bae;Joo, Nak-Keun;Kang, Moon-Seol
    • The KIPS Transactions:PartD
    • /
    • v.10D no.3
    • /
    • pp.541-546
    • /
    • 2003
  • We present a random bit generator that uses fingerprint image as the source of random, and the random bit generator is the first generator in the world that uses biometric information for the source of random in the world. The generator produces, on the average, 9,334 bits a fingerprint image in 0.03 second, and the produced bit sequence passes all 16 statistical tests that are recommended by NIST for testing the randomness.

A Postal Transportation Planning Algorithm (우편물 기간운송계획 알고리듬)

  • 최지영;이경식;박성수;김진석;김혜규
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2001.10a
    • /
    • pp.191-194
    • /
    • 2001
  • We consider a postal transportation planning in the transportation network of the form of hub and spoke. Given mail sorting centers and an exchange center, available vehicles and amount of mails to be transported between mail sorting centers, postal transportation planning is to make a transportation plan without violating various restrictions. The objective is to minimize the total transportation cost. To solve the problem, a tabu search algorithm is Proposed. The algorithm is composed of a route construction procedure and a route improvement procedure to improve a solution obtained by the route construction procedure using a tabu search. Computational results show that the proposed algorithm can solve practically sized problems within a reasonable time and the quality of the solution is acceptable.

  • PDF

M/G/1 복수 휴가 모델을 이용한 IEEE 802.16e 무선 MAN 수면모드 작동에 대한 성능분석

  • Jeong, Seong-Hwan;Hong, Jeong-Wan;Jang, U-Jin;Lee, Chang-Hun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2007.11a
    • /
    • pp.195-203
    • /
    • 2007
  • In this paper, an analytic model of sleep model operation in the IEEE 802.16e is investigated. A mobile subscribe. station (MSS) goes to sleep mode after negotiations with the base station (BS) and wakes up periodically for a short interval to check whether there is downlink traffic to it. If the arrival of traffic is notified, an MSS returns to wake mode. Otherwise, it again enters increased sleep interval which is double as the previous one. In order to consider the situation more practically, we propose the sleep mode starting threshold, during which MSS should await packets before it enters the sleep mode. By modifying the M/G/1 with multiple vacations model, energy consumption ratio(ECR) and average packet response time are calculated. Our analytic model provides potential guidance in determining the optimal parameters values such as sleep mode starting threshold, minimal sleep and maximal sleep window.

  • PDF

Performance Measure of Multiple Characteristics in Parameter Design (다특성치 파라미터 설계의 평가척도에 관한 연구)

  • Kim, Wook Il;Kang, Chang Wook
    • Journal of Korean Society for Quality Management
    • /
    • v.22 no.1
    • /
    • pp.122-132
    • /
    • 1994
  • So far, the Taguchi Method has dealt with multiple quality characteristics under the assumption that they are independent. Since the relationships between quality characteristics are practically important, this study proposes a new performance measure considering the correlation among characteristics. In this paper, we impose weight on each characteristic and correlation among characteristics. The loss function of multiple characteristics is defined in accordance with combination of simple characteristic types, and it is divided into terms of loss that characteristic itself and the correlation among characteristics cause. And the proposed method uses the expected loss of multiple characteristics as the new performance measure. The data in literature are used to compare with the existing performance measures.

  • PDF

Adsorption characteristics of the zeolite for flue gas desulfurization (제올라이트의 아황산가스흡 ${\cdot}$ 탈착특성)

  • Park, Hyun-Hee;Mo, Se-Young
    • Journal of environmental and Sanitary engineering
    • /
    • v.18 no.3 s.49
    • /
    • pp.43-47
    • /
    • 2003
  • The desorption characteristics of NaY zeolite, of which Si/Al ratio is 2.36, was measured at 25${\circ}$C and 150${\circ}$C so as to be used practically as a adsorbent for separation of sulfur oxides from flue gas, for which adsorption and desorption cycles at 25${\circ}$C were repeated four times and that at 150${\circ}$C was done one time. As a result it took 30.8 at 150${\circ}$C and 164.1 minutes in average at 25${\circ}$C to reach equilibrium condition. It means that regeneration of the NaY zeolite can be done below 150${\circ}$C so that zeolite can be used for flue gas desulfurization.