• Title/Summary/Keyword: ppd

Search Result 289, Processing Time 0.023 seconds

Retrospective analysis of keratinized tissue augmentation using a xenogeneic collagen matrix for resolving peri-implant mucositis and peri-implantitis

  • Jung Soo Park;Yeek Herr;Jong-Hyuk Chung;Seung-Il Shin;Hyun-Chang Lim
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.2
    • /
    • pp.145-156
    • /
    • 2023
  • Purpose: The significance of keratinized tissue for peri-implant health has been emphasized. However, there is an absence of clinical evidence for the use of a xenogeneic collagen matrix (XCM) to manage peri-implant mucositis and peri-implantitis. Therefore, the purpose of this study was to investigate outcomes after keratinized tissue augmentation using an XCM for the management of peri-implant diseases. Methods: Twelve implants (5 with peri-implant mucositis and 7 with peri-implantitis) in 10 patients were included in this study. Non-surgical treatments were first performed, but inflammation persisted in all implant sites. The implant sites all showed a lack of keratinized mucosa (KM) and vestibular depth (VD). Apically positioned flaps with XCM application were performed. Bone augmentation was simultaneously performed on peri-implantitis sites with an intrabony defect (>3 mm). The following clinical parameters were measured: the probing pocket depth (PPD), modified sulcular bleeding index (mSBI), suppuration (SUP), keratinized mucosal height (KMH), and VD. Results: There were no adverse healing events during the follow-up visits (18±4.6 months). The final KMHs and VDs were 4.34±0.86 mm and 8.0±4.05 mm, respectively, for the sites with peri-implant mucositis and 3.29±0.86 mm and 6.5±1.91 mm, respectively, for the sites with peri-implantitis. Additionally, the PPD and mSBI significantly decreased, and none of the implants presented with SUP. Conclusions: Keratinized tissue augmentation using an XCM for sites with peri-implant mucositis and peri-implantitis was effective for increasing the KMH and VD and decreasing peri-implant inflammation.

Evaluation of the effectiveness of diode laser therapy in conjunction with nonsurgical treatment of periimplantitis

  • Dicle Altindal;Eylem Ayhan Alkan;Metin Calisir
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.376-387
    • /
    • 2023
  • Purpose: Peri-implantitis (PI) is an inflammatory condition associated with the destruction of bone tissue around a dental implant, and diode lasers can be used to treat this disease. In this study, we aimed to evaluate the effectiveness of a 940-nm diode laser for the nonsurgical treatment of PI. Methods: Twenty patients (8 women and 12 men) were enrolled in a split-mouth randomized controlled study. In the control group (CG), mechanical debridement with titanium curettes accompanied by airflow was performed around the implants. The test group (TG) was treated similarly, but with the use of a diode laser. Clinical measurements (plaque index, gingival index [GI], probing pocket depth [PPD], bleeding on probing [BOP], clinical attachment level, and interleukin-1β [IL-1β] in the peri-implant crevicular fluid) were evaluated and recorded at baseline and 3 months. IL-1β levels were determined using the enzyme-linked immunosorbent assay method. Results: The symptoms were alleviated in both groups at 3 months as assessed through clinical measurements. GI, BOP, and PPD were significantly lower in the TG than in the CG (P<0.05). The IL-1β level increased post-treatment in both groups, but this increase was only statistically significant (P<0.05) in the CG. Conclusions: The diode laser enabled improvements in clinical parameters in the periimplant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.

Particulate Matter and CO2 Improvement Effects by Vegetation-based Bio-filters and the Indoor Comfort Index Analysis (식생기반 바이오필터의 미세먼지, 이산화탄소 개선효과와 실내쾌적지수 분석)

  • Kim, Tae-Han;Choi, Boo-Hun;Choi, Na-Hyun;Jang, Eun-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.37 no.4
    • /
    • pp.268-276
    • /
    • 2018
  • BACKGROUND: In the month of January 2018, fine dust alerts and warnings were issued 36 times for $PM_{10}$ and 81 times for PM2.5. Air quality is becoming a serious issue nation-wide. Although interest in air-purifying plants is growing due to the controversy over the risk of chemical substances of regular air-purifying solutions, industrial spread of the plants has been limited due to their efficiency in air-conditioning perspective. METHODS AND RESULTS: This study aims to propose a vegetation-based bio-filter system that can assure total indoor air volume for the efficient application of air-purifying plants. In order to evaluate the quantitative performance of the system, time-series analysis was conducted on air-conditioning performance, indoor air quality, and comfort index improvement effects in a lecture room-style laboratory with 16 persons present in the room. The system provided 4.24 ACH ventilation rate and reduced indoor temperature by $1.6^{\circ}C$ and black bulb temperature by $1.0^{\circ}C$. Relative humidity increased by 24.4% and deteriorated comfort index. However, this seemed to be offset by turbulent flow created from the operation of air blowers. While $PM_{10}$ was reduced by 39.5% to $22.11{\mu}g/m^3$, $CO_2$ increased up to 1,329ppm. It is interpreted that released $CO_2$ could not be processed because light compensation point was not reached. As for the indoor comfort index, PMV was reduced by 83.6 % and PPD was reduced by 47.0% on average, indicating that indoor space in a comfort range could be created by operating vegetation-based bio-filters. CONCLUSION: The study confirmed that the vegetation-based bio-filter system is effective in lowering indoor temperature and $PM_{10}$ and has positive effects on creating comfortable indoor space in terms of PMV and PPD.

Usefulness of Tuberculin Skin Test by Tuberculin PPD RT23 2 TU (Tuberculin PPD RT23 2 TU를 이용한 투베르쿨린 피부반응 검사의 의의)

  • Yang, Jong-Wuk;Jeon, Man-Jo;Kim, Sung-Jung;Lee, Hyang-Lim;Lee, Seung-Jun;Lee, Myoung-Goo;Kim, Dong-Gyu;Park, Myoung-Jae;Kang, Min-Jong;Hyoen, In-Gyu;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.4
    • /
    • pp.401-408
    • /
    • 2002
  • Background : Tuberculin skin test is a method to examine M. tuberculosis infection and has been used all over the world. But various factors make it difficult to understand testing results. In 2000, the American Thoracic Society recommended that skin test results should be decided by considering risk factors of the tested. In Korea, high tuberculosis infection rate and BCG vaccination rate make it difficult to differentiate current infection, past infection, and no infection by the skin test. This study was attempted to examine a negative predictive value of the skin test to understand how the skin test acts on deciding administration of anti-tuberculosis drug. Methods : From Mar. 1 to Jul. 31 in 2001, the test was performed for patients hospitalized in Department of Internal Medicine, Hallym University College of Medicine, Chunchon, Korea by administering Tuberculin PPD RT23 2 TU (0.1 ml)to them that has been currently used in Korea based on Mantoux method. They were decided to be infected with tuberculosis bacilli by following diagnostic standard: 1) tuberculosis bacilli was cultured in sputum by microbiological diagnostic standard or Acid-fast bacilli was proven on a microscopic examination or 2) tuberculosis bacilli was not proven in the aforesaid microbiological test by clinical diagnostic standard, while there was opinion or symptom suitable for tuberculosis by radiographic or histological standard so the doctor decided to apply the tuberculosis treatment. Results : In this study, total 210 patients except 20 patients (8.7%) among 230 hospitalized patients were evaluated. Their average age was 60±16.8 years, and male-female rate was 1.28 : 1 (male: 118, female: 92). Number of patient, who was diagnosed and decided as tuberculosis, was 53(25.2%). Pulmonary tuberculosis was found in 45 patients (84.9%); 22 patients were decided to be positive in the Acid-fast bacilli smear test by microbiological examination (culture positive: 13, culture negative: 9), and 23 patients were decided to be tuberculosis patients by clinical diagnosis standard. Tuberculosis pleuritis was found in 8 patients (15.1%); 4 patients were diagnosed and decided by histological standard, and 4 patients were decided and treated by clinical standard. In differentiating patients into 'Negative' and 'Positive' by the skin test standard of the American Thoracic Society, negative predictive value 92.3%, positive predictive value 47.3%, sensitivity and specificity were 83%, 68.8%, respectively. Conclusion : In hospitalized respiratory patients, there was high negative predictive vlaue 92.3% by tuberculin skin test, therefore skin test would be a important factor for deciding administration of anti-tuberculosis drug on negative skin test patient.

The Nationwide NO$_2$Monitoring with Passive Sampler in Korea

  • Kim, Sun-Tae;Kim, Han-Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E2
    • /
    • pp.69-77
    • /
    • 2002
  • The nationwide NO$_2$monitoring program has been carried out using the passive sampler in Korea since 1993. During the sixteenth periods of measurement, total 26,474 sites of data were collected through eight years. In this paper, the roadside NO$_2$concentration of six major cities were analyzed. As results, the most frequent NO$_2$concentration of Seoul, Incheon, and Daegu ranged from 40 to 60 ppb, and that of Pusan, Kwanju, and Daejeon was from 20 to 40 ppd. Despite that the automobile number of Incheon was less than that of Daegu and Pusan, the exceedence rate of Korean national ambient air quality standard and ninetieth percentile concentration of Incheon were almost the same level as Seoul. In addition, the mean and standard deviation of roadside NO$_2$concentration of Seoul and Incheon was also appeared to be higher than that of other cities. These results indicates that NO$_2$concentration on roadside was affected by the traffic volumes and the traffic flow conditions.

A Study on Biofilm Detachment in an IFBBR (역 유동층 생물막 반응기에서의 생물막 탈착에 관한 연구)

  • 김동석;박영식
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.263-271
    • /
    • 1994
  • A detachment of biofilm was investigated in an inverse fluidized bed biofilm reactor(IFRBR). The biofilm thickness, 5 and the bioparticle density, Pm were decreased by the increase of Reynolds number, Re and the decrease of biomass concentration, h. The correlations were expressed as $\delta$=6l.6+16.33$b_c$-0.004Re and Ppd=0.3+0.027$b_c$- 2.93x$l0^{-5}$ no by multiple linear regression analysis method. Specific substrate removal rate, q was derived by F/M ratio and biofilm thickness as q=0.44.+0.82F/M-5.Ix10$-4^{$\delta$}$. Specific biofilm detachment rate, bds was influenced by FIM ratio and Reynolds number as $b_{ds}$=-0.26+0.26F/M+ 2.17$\times$$10^{-4}$Re. Specific biofilm deachment rate in an IFBBR was higher than that in a FBRR(fluidized bed biofilm reactor) because of the friction between air bubble and the bioparticles.

  • PDF

A study on the synthesis and characterization of PI/$\textrm{TiO}_2$ nano-composite (폴리이미드/$\textrm{TiO}_2$ 나노 복합재의 합성 및 특성에 관한 연구)

  • 이중희;이봉신;허석봉
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.137-140
    • /
    • 2001
  • Oragnic/inorganic hybrid materials prepared by sol-gel method have rapidly become a fasci nating research field in materials science. In this study, Polyimide/$\textrm{TiO}_2$ composites were synthesized from nano-sized anatase $\textrm{TiO}_2$ and two types of Polyimide (BTDA-PPD, PMDA-ODA) by Sol-gel method. Nano-sized $\textrm{TiO}_2$ particles were prepared from $\textrm{TiOEt}_4$ solution. The composites were charcaterized by using XRD, TGA, IR, TEM, and Atomic Force Microscope(AFM). $\textrm{TiO}_2$ nano particles were dispersed well in polyimide matrix and the thermal stability of polyimide was improved with $\textrm{TiO}_2$ nano-sized particles.

  • PDF

Internet Protocols Over ABR and UBR Services: Problems, Approaches, and Their Evaluation (ABR과 UBR 서비스 상에서 인터넷 프로토콜: 문제점, 해결방안, 그리고 성능평가)

  • Park, Seung-Seop;Yuk, Dong-Cheol
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.11S
    • /
    • pp.3260-3268
    • /
    • 1999
  • As the proliferation of multimedia traffic over High-speed Internet increases, ATM network will be vital to adopt as backbone network over various parts of Internet. In this paper, we investigate the performance of TCP/IP traffic flow over ABR and UBR of ATM service to study for the high throughput and good fairness by simulation technique. Although TCP is run in the transport layer, it is controlled by several methods, e.g, EPD, PPD, RED, EFCI, ER etc, in ATM layer when TCP uses the ABR/UBR service. Therefore, if one cell is discarded in ATM layer, a packet of TCp will be laost. And, also, along with the increasing of the number of VC among switches, the throughput and fairness will be degraded. In order to improve these degradations, we propose the effective parameter control operations of EFCI and ER on ABR service, and also suggest the buffer management methods on UBR service. Finally, through the simulation results, the improved throughput and fairness are shown.

  • PDF

A Study on the Development of a pub level Silica Measuring Technology by the Split-beam Type System (스플리트빔 형태의 고정도 단위 실리카 측정기술 개발에 관한 연구)

  • 정경열;류길수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.382-388
    • /
    • 2002
  • Dissolved silica is one of fatal components at a boiler facility Therefore, a dissolved silica measurement system should be equipped for managing efficiently the boiler facility. Most of silica measurement systems are composed of a sensor module of single-beam type structure, and silica density is measured with a infrared spectrometry using the Lambert-beer method. However, such a system occurs measuring error of large range and inconsistency of a light source, because of measuring a standard sample and a measuring sample alternatively. This paper introduces a method that the sensor module has a split-beam type structure and a tungsten lamp. The proposed system can measure silica density quickly and precisely more than those composing of a single-beam type structure, because of measuring and comparing with two samples at a same time. And examination results are shown to compare efficiencies of the system and existing commercial products, and for an ammonia influence.

Electrical Characterization of Organo Sulfur Compound-Polyphenylenediamine Positive Electrode in Lithium Battery (유기황화합물-Polyphenylenediamine리튬전지용 정극의 전기적특성)

  • 박수길;박종은;손원근;김상욱;임기조;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.261-264
    • /
    • 1997
  • Polyphenylenediamine(PPD)film was prepared with organo sulfur compond (2-aminothiophenol, 1,2-ethanedithiol, and 2-aminoethaneethiol etc.) adding lithium salt to increase the electrical conductivity of the polymer surface. The molecular structure of conductive polymer synthesized were examined and discussed by using SEM, FT-IR, NMR etc. The elecrical conductivity messurement were carried out with four-probe method at dry box of He and $N_2$atmosphere. The typical value of successful electrical conductivity was 1.2$\times$10$^1$S/cm at room temperature.

  • PDF