• 제목/요약/키워드: power transformer protection

검색결과 151건 처리시간 0.023초

표준형 지상변압기 개발에 관한 연구 (A study on development of the standard PAD-mounted type Transformer)

  • 조국희;김광화;양태권;홍원식;조양섭;김양태
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1997년도 추계학술발표회논문집
    • /
    • pp.74-77
    • /
    • 1997
  • As underground distribution systems to be operated in downtown have more merits than overhead distribution system, underground distribution systems are being increased. But when pad-mounted transformers have troubles, reptures and fires can be occurred. We think that this makes accidents and power failures of bulidings and generates malaise and a great economic loss. In order to increase the reliability of pad-mounted transformers, we have investigated transformers and understood their failure mechani는. Therefore, we would have objectives and necessities of this study to improve quality and operating condition and install switches to be able to check and maintain transformers and optimize protection devices and increase cooling effect in pad-mounted transformers.

  • PDF

전력용변압기보호를 위한 개선된 수치계전기법 (Advanced Numerical Relaying for Power Transformer Protection)

  • 박철원;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.217-219
    • /
    • 2004
  • The second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic-restrained RDR needs modification. This paper describes an advanced numerical algorithm that utilizes terminal voltage, differential current harmonics, harmonic ratio, and flux-differential current slope. Based on the results of testing with WatATP99 simulation data, the proposed algorithm was proven to be faster and more reliable.

  • PDF

A High Efficiency Controller IC for LLC Resonant Converter in 0.35 μm BCD

  • Hong, Seong-Wha;Kim, Hong-Jin;Park, Hyung-Gu;Park, Joon-Sung;Pu, Young-Gun;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.271-278
    • /
    • 2011
  • This paper presents a LLC resonant controller IC for secondary side control without external active devices to achieve low profile and low cost LED back light units. A gate driving transformer is adopted to isolate the primary side and the secondary side instead of an opto-coupler. A new integrated dimming circuitry is proposed to improve the dynamic current control characteristic and the current density of a LED for the brightness modulation of a large screen LCD. A dual-slope clock generator is proposed to overcome the frequency error due to the under shoot in conventional approaches. This chip is fabricated using 0.35 ${\mu}m$ BCD technology and the die size is $2{\times}2\;mm^2$. The frequency range of the clock generator is from 50 kHz to 500 kHz and the range of the dead time is from 50 ns to 2.2 ${\mu}s$. The efficiency of the LED driving circuit is 97 % and the current consumption is 40 mA for a 100 kHz operation frequency from a 15 V supply voltage.

태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구 (Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders)

  • 김병기;김소희;유경상;노대석
    • 한국융합학회논문지
    • /
    • 제2권4호
    • /
    • pp.29-37
    • /
    • 2011
  • 종래의 배전계통에 있어서의 전력조류는 변전소에서 선로말단을 향한 단 방향이었지만, 신에너지전원(분산전원)이 연계된 배전계통의 경우에는 그 출력용량의 여부에 따라 양방향의 전력조류가 발생할 가능성이 있어, 계통운용상 여러 가지의 문제점이 야기될 수 있다. 분산전원은 대규모전원의 보완적 역할과 배전선로 상의 국부적 부하 감당 역할을 부과하여 그의 적극적 활용을 꾀하기 위해서는, 분산전원으로부터 배전계통에 전력을 공급하는 역 조류의 기능을 허용할 수 있는 양방향 보호협조방식의 체제를 확립할 필요가 있다. 따라서 본 연구에서는 분산전원 연계에 따른 보호협조 기본 방안과 부하절체 운전에 따른 보호협조 방안, 변압기결선에 따른 보호협조 방안 등에 대한 알고리즘을 제시하였다. 또한, 이론적인 계산법(대칭좌표법)과 MATLAB/SIMULINK에 의하여 실 계통에서의 양방향 보호협조에 관련된 문제점을 분석하고, 해결방안을 제시하였다.

The Development of the ±80kV 60MW HVDC System in Korea

  • Park, Kyoung-Ho;Baek, Seung-Taek;Chung, Yong-Ho;Jang, Gil-Soo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.594-600
    • /
    • 2017
  • HVDC transmission systems can be configured in many ways to take into account cost, flexibility and operational requirements. [1] For long-distance transmission, HVDC systems may be less expensive and suffer lower electrical losses. For underwater power cables, HVDC avoids the heavy currents required to charge and discharge the cable capacitance of each cycle. For shorter distances, the higher cost of DC conversion equipment compared to an AC system may still be warranted, due to other benefits of direct current links. HVDC allows power transmission between unsynchronized AC transmission systems. Since the power flow through an HVDC link can be controlled independently of the phase angle between the source and the load, it can stabilize a network against disturbances due to rapid changes in power. HVDC also allows the transfer of power between grid systems running at different frequencies, such as 50 Hz and 60 Hz. This improves the stability and economy of each grid, by allowing the exchange of power between incompatible networks. This paper proposed to establish Korean HVDC technology through a cooperative agreement between KEPCO and LSIS in 2010. During the first stage (2012), a design of the ${\pm}80kV$ 60MW HVDC bipole system was created by both KEPCO and LSIS. The HVDC system was constructed and an operation test was completed in December 2012. During the second stage, the pole#2 system was fully replaced with components that LSIS had recently developed. LSIS also successfully completed the operation test. (2014.3)

공기압을 이용한 전기설비 침수 방지 장치 개발에 관한 연구 (The development for flooding prevention apparatus of electrical equipment using air pressure)

  • 김기현;전현재;이상익;배석명;이재용
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.281-284
    • /
    • 2008
  • Inundation of substation and ground power equipment breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation excluding the exchanging cost of equipment, it occurs a great economic and social loss owing to recovery time and events of electric shock occur by inundation electrical equipment(Pad-mounted Transformer and Switch). In case of installing the power equipment at flood danger territory, we are necessary to the product development, the product is that water does not come in the inside the power equipment. Product of pressure maintaining are established on the basic frame and sensor operates at the flooding occurrence and is maintained a shutting tightly structure and it is a method. The product which is produced the reliability of the product it confirmed a flooding yes or no from the condition which puts in the water tank and it verified. We estimate that loss cost which is caused by with flooding and the power failure will be diminished if it is addition to advances the reliability evaluation and a security of the flood protection product.

  • PDF

22.9kV 수전설비에서 측정된 과도과전압의 특성 (Features of Transient Overvoltages Observed at 22.9kV Consumer's Substation)

  • 심해섭;이복희
    • 조명전기설비학회논문지
    • /
    • 제28권9호
    • /
    • pp.52-59
    • /
    • 2014
  • The aims of this paper are to characterize the transient overvoltages(TOVs) and to evaluate the risk occurring at 22.9kV consumer's substation. The measurements of lightning- and switching-caused TOVs were made during Mar. 2013 and Feb. 2014. As a consequence, 47 events of TOVs were recorded and 4 of them were higher than the input voltage envelope(IVE) of the information technology industry council(ITI) curve. The measured TOVs are characterized by longer front times and longer durations compared to the $1.2/50{\mu}s$ standard impulse voltage waveform, and some of them represent bipolar waves with lower oscillation frequencies. It suggests that the test of non-standard impulse voltage waveforms is needed for effective risk assessments of power apparatus. Lightning- and switching-caused TOVs exceeding IVE of ITI curve are induced at the secondary of 22.9kV potential transformer(PT). We may, therefore, conclude that the surge protection devices should be applied at the secondary of PT and the surge absorbers should be installed at the primary of VCB or PT. The results presented in this paper could be useful to design the reasonable insulation coordination for 22.9kV consumer's substation.

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

Si3N4 박막의 유기발광소자 수분침투 방지막으로의 응용 (Application of Si3N4 Thin Film as a Humidity Protection Layer for Organic Light Emitting Diode)

  • 김창조;신백균
    • 한국전기전자재료학회논문지
    • /
    • 제23권5호
    • /
    • pp.397-402
    • /
    • 2010
  • In this paper, we studied WVTR(water vapor transmission rate) properties of $Si_3N_4$ thin film that was deposited using TCP-CVD (transformer coupled plasma chemical vapor deposition) method for the possibility of OLED(organic light emitting diode) encapsulation. Considering the conventional OLED processing temperature limit of below $80^{\circ}C$, the $Si_3N_4$ thin films were deposited at room temperature. The $Si_3N_4$ thin films were prepared with the process conditions: $SiH_4$ and $N_2$, as reactive gases; working pressure below 15 mTorr; RF power for TCP below 500 W. Through MOCON test for WVTR, we analyzed water vapor permeation per day. We obtained that WVTR property below 6~0.05 gm/$m^2$/day at process conditions. The best preparation condition for $Si_3N_4$ thin film to get the best WVTR property of 0.05 gm/$m^2$/day were $SiH_4:N_2$ gas flow rate of 10:200 sccm, working pressure of 10 mTorr, working distance of 70 mm, TCP power of 500 W and film thickness of 200 nm. respectively. The proposed results indicates that the $Si_3N_4$ thin film could replace metal or glass as encapsulation for flexible OLED.

고조파발생에 따른 영향과 대책 연구 (Effect of Harmonic Generation and Countermeasures)

  • 백동현
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.91-97
    • /
    • 2015
  • 초고층건축물이나 대형 사업장과 IT를 추구하는 수용가는 많은 가전기기 사용하여 선형, 비선형부하시의 고조파로인한 Capacitor의 과열 및 소손, 자료 손상, 대지전위 상승, 통신유도장해등을 일으켜 전력설비의 오동작과 과열로 화재의 원인이 될 수 있다. 이를 확인하기 위해 건축물의 7곳을 조사하여 비교한 결과 6곳에서는 적정하였으나 1곳은 고조파관리가 필요하였다. 전류 고조파는 No. 3, 6, 7은 매우 초과하여 정밀 진단이 필요하였으며 No. 2, 3, 5는 5고조파 전류를 고려하여야 한다. R상 전압고조파는 양호하였으나 전류고조파는 No. 1을 제외하고 No. 2, 3, 4, 5, 6, 7은 모두 기준을 초과하였다. 따라서 지그재그변압기나 엑티브필터를 설치하여 고조파 상승을 억제시킬 필요가 있고 설비불평형률, 역률등을 종합 조사하여 효율도 향상시킬 필요가 있다.