• 제목/요약/키워드: power system protection

Search Result 1,273, Processing Time 0.026 seconds

Analysis on the Operation Characteristics and Protection Coordination between the Current Ratio Differential Relay for Line Protection and the Trigger-type SFCL in the Power Transmission System (송전급 초전도한류기의 적용에 따른 선로보호용 비율전류차동계전기의 동작특성 및 보호협조 분석)

  • Cho, Yong-Sun;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.925-930
    • /
    • 2013
  • The fault current of the power transmission system is greater than that of the power distribution system. Therefore, the introduction of superconducting fault current limiter (SFCL) is more needed to reduce the increased fault current. The trigger-type SFCL consists of the high-temperature superconducting element (HTSC), the current limiting reactor (CLR) and the circuit breaker (CB). The trigger-type SFCL can be used to supplement the disadvantages of the resistive-type SFCL. The operation characteristics of the current ratio differential relay which is usually applied to the protection device of the power transmission system are expected to be affected under fault conditions and the applicability of the trigger-type SFCL. In this paper, we analyzed the operating characteristics, by the fault conditions, between the current ratio differential relay for line protection and the trigger-type SFCL in the power transmission system through the PSCAD/EMTDC simulation.

Power system protection IED design using an embedded processor (임베디드 프로세서를 이용한 계통 보호 IED 설계)

  • Yoon, Ki-Don;Son, Young-Ik;Kim, Kab-Il
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.711-713
    • /
    • 2004
  • In the past time, the protection relay did only a protection function. Currently, its upgraded device i.e. IED(Intelligent Electric Device) has been designed to protect, control, and monitor the whole power system automatically. Also the device is desired to successfully measure important elements of the power system. This paper considers design method of a digital protection IED with a function of measuring various elements and a communication function. The protection IED is composed of the specific function modules that are signal process module, communication module, input/output module and main control module. A signal process module use a DSP processor for analysis of input signal. Main control module use a embedded processor, Xscale, that has an ARM Core. The communication protocol uses IEC61850 protocol that becomes standard in the future. The protection IED is able to process mass information with high-performance processor. As each function module is designed individually, the reliability of the device can be enhanced.

  • PDF

Development of Web-based Protection Relay Setting Program in Power System (전력시스템 보호를 위한 웹기반 계전기 정정 프로그램 개발)

  • Bok, Jeong-Song;Jeong, Ho-Sung;Shin, Myong-Chul;Cho, In-Suk;Seo, Hee-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.246-248
    • /
    • 2001
  • For protection of power system, it is a prerequisite to action characteristics of protective relay about a changing environment in power system and correcting the setting value. A substation operator always reside to correct of a relay, however there are problem of efficiency. Recently, power system operation become manless and supervision and control of incident is required anywhere, introduction of new concept as a intellectual manless protective relay is a recent trend. This paper is the web-based protective relay setting program that a manager make an analysis of operation and incident of power system through the web at a remote place corresponding recent manless of system and approach the protection relay and then can correct the error.

  • PDF

A Study on Trouble and Arrangement of the Ground-Fault Protection for 2 Step Voltage Distribution System of Premises (2 Step 이상 운용 고객의 구내배전계통 지락보호시스템 구성 현황 및 문제점 검토)

  • Im, Jin-Sung;Shin, Myoung-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.73-77
    • /
    • 2010
  • Most accidents occurred in power receiving & transforming facility are ground fault. The quality of power supply is deteriorated since the ground fault is not detected promptly. This paper analyzes the problems about system-grounding type of 2 step power receiving & transforming facility, arrangement of protection relaying scheme and ground-fault protection system of ungrounded system. Then, this paper presents the arranging scheme of system-grounding type to improve power supply reliability.

FACTS controller design for improving Power System damping (제동력 향상을 위한 FACTS기기제어)

  • Yoon, Jong-Su;Lee, Gun-Jun;Moon, Gun-Woo;Yoon, Suk-Ho;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.835-837
    • /
    • 1997
  • This paper presents a control system design for the STATCON of FACTS devices by LQR, LQG control scheme to enhance small-signal stability in the power system, the feature of this FACTS controller is coordinated with generator exciter controller(AVR, PSS) to improve the total power system stability and performance.

  • PDF

Parametric Evaluation Method of Protectability in a Distribution System (파라메터 관점에서의 배전계통 보호도 평가방법)

  • Cho, P.S.;Hyun, S.H.;Lim, S.I.;Lee, S.J.;Lee, D.S.;Waldemar, Waldemar
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.241-243
    • /
    • 2002
  • Recently, great efforts are concentrated on the autonomous, adaptive protection schemes with advanced artificial intelligence and digital technology. It is highly required for a next generation protective system not only to detect and to clear a fault, but also to fit itself to the changing environment. In this paper it is suggested an evaluation method for the protection ability of a protective system in a distributed system. The suggested method is of bottom-up scheme, in other words, protection ability is estimated from the lowest level of parameters in each protective devices to the highest level of the whole protective system. This feature makes it possible to evaluate the protection ability either for the protective device(or a system), or for a protected system. And, in addition, it is enabled that the protectability concept can be applied in the design stage of a protective system for a distribution network. The proposed method is applied to a simple distributed network to show its effectiveness.

  • PDF

A Study on Chaining Threat Analysis of Cybersecurity against Reactor Protection Systems (원자로보호계통 사이버보안 연계 위협 분석 연구)

  • Jung, Sungmin;Kim, Taekyung
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.18 no.2
    • /
    • pp.39-48
    • /
    • 2022
  • The application of digital technology to instrumentation and control systems in nuclear power plants has overcome many shortcomings of analog technology, but the threat of cybersecurity has increased. Along with other systems, the reactor protection system also uses digital-based equipment, so responding to cybersecurity threats is essential. We generally determine cybersecurity threats according to the role and function of the system. However, since the instrumentation and control system has various systems linked to each other, it is essential to analyze cybersecurity threats together between the connected systems. In this paper, we analyze the cybersecurity threat of the reactor protection system with the associated facilities. To this end, we quantitatively identified the risk of the reactor protection system by considering safety functions, a communication type, the use of analog or digital-based equipment of the associated systems, and the software vulnerability of the configuration module of the reactor protection system.

Development and Implementation of an Over-Temperature Protection System for Power Semiconductor Devices (전력용 반도체 소자의 과열보호시스템 설계 및 구현)

  • Choi, Nak-Gwon;Lee, Sang-Hoon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.163-168
    • /
    • 2010
  • This paper presents the practical implementation of an over-temperature protection system for power semiconductor devices. In the proposed system, temperature variation is provided with just using $R_{ds(on)}$ characteristics of power MOSFET, while extra device such as a temperature sensor or an over-temperature detection transistor is needed to monitor the temperature in the conventional method. The proposed protection technique is experimentally tested on IRF840 power MOSFET. The PIC microcontroller PIC16F877A is used for the implementation of the proposed protection algorithm. The built-in 10-bit A/D converter is utilized for detecting voltage variance between a drain and a source of IRF840. The induced temperature-resistance relationship based on the measured drain-source voltage, supplies a gate signal to the power MOSFET. If detected temperature's voltage exceeds any a protection temperature's voltage, the microcontroller removes the trigger signal from the power MOSFET. These test results showed satisfactory performances of the proposed protection system in term of accuracy within 1.5%.

Concept Development of Core Protection Calculator with Trip Avoidance Function using Systems Engineering

  • Nascimento, Thiago;Jung, Jae Cheon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.2
    • /
    • pp.47-58
    • /
    • 2020
  • Most of the reactor trips in Korean NPPs related to core protection systems were caused not because of proximity of boiling crisis and, consequently, a damage in the core, but due to particular miscalculations or component failures related to the core protection system. The most common core protection system applied in Korean NPPs is the Core Protection Calculator System (CPCS), which is installed in OPR1000 and APR1400 plants. It generates a trip signal to scram the reactor in case of low Departure from Nucleate Boiling Ratio (DNBR) or high Local Power Density (LPD). However, is a reactor trip necessary to protect the core? Or could a fast power reduction be enough to recover the DNBR/LPD without a scram? In order to analyze the online calculation of DNBR/LPD, and the use of fast power reduction as trip avoidance methodology, a concept of CPCS with fast power reduction function was developed in Matlab® Simulink using systems engineering approach. The system was validated with maximum of 0.2% deviation from the reference and the dynamic deviation was maximum of 12.65% for DNBR and 6.72% for LPD during a transient of 16,000 seconds.

Digital Ratio Differential Relaying for Main Protection of Large Generator (대형 발전기 주보호를 위한 디지털 비율차동 계전기법)

  • Park, Chul-Won;Ban, Yu-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.61 no.1
    • /
    • pp.35-40
    • /
    • 2012
  • An AC generator is an important component in producing an electric power and so it requires highly reliable protection relays to minimize the possibility of demage occurring under fault conditions. It is a need for research of digital generator protection system(DGPS) for the next-generation ECMS and an efficient operation of protection control system in power station. However, most of protection and control system used in power plants have been still imported as turn-key and operated in domestic. This may cause the lack of the correct understanding on the protection systems and methods, and thus have difficulties in optimal operation. In this paper, presented ratio differential relaying(RDR) is main protective element in generator protection IED. The fault detection technique, operation zone and setting value of the RDR were studied and, compared with two of the fault detection algorithm. For evaluation performance of the RDR, the data obtained from ATPDraw5.7p4 modeling was used. The proposed methods are shown to be able to rapidly identify internal fault and did not operate a miss-operation for all the external fault.