• 제목/요약/키워드: power system protection

검색결과 1,270건 처리시간 0.032초

A Protection Circuit for the Power Supply of a Gas Discharge Lamp

  • Kim, Ho-Sung;Kim, Jong-Hyun;Baek, Ju-Won;Yoo, Dong-Wook;Jung, Hye-Man;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • 제10권6호
    • /
    • pp.777-783
    • /
    • 2010
  • In order to drive gas discharge lamps, DC-AC converters with a LCC resonant tank, whose output voltage is adjusted by a variable frequency control are frequently used. However, when they are activated by varying the operating frequency, converters are frequently damaged by unstable operation, due to the rising and falling of the operating frequency near the resonant frequency. To solve this problem, a simple protection circuit for the power supply of a gas discharge lamp is proposed in this paper. This circuit senses the primary current of the main transformer. Using this protection circuit, the operating frequency of the lamp driving inverter system is kept close to and on the right side of the resonant frequency and the inverter is always operated in the ZVS condition. The resulting stable variable frequency operation allows various gas discharge lamps to be tested without the risk of damaging the main switches, because the protection circuit can protect the power MOSFETs of bridge converters from abnormal conditions. The validity and effectiveness of the proposed protection circuit are verified through the experimental results.

분산 전원 계통 연계용 보호 IED의 설계 및 구현 (Realization of Protection IED for Distributed Power System)

  • 한철완;오성남;김갑일;손영익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.517-519
    • /
    • 2005
  • In this paper, we consider a digital protection IED(Intelligent Electric Device) for a distributed power system. The IED can measure various elements for protection and communicate with another devices through network. The protection IED is composed of specific function modules: signal process module which converts analog signal from PT and CT handle algorithm to digital one; communication module for connection with another IEDs; input/output module for user-interfaces. A general purpose DSP board with TMS320C2812 is used in the IED. In order to verify the proposed IED, experimental researches with the power system simulator DOBLE has been carried out for a phase earth fault. The results show an under-voltage relaying algorithm has been realized sucessfully in the hardware system.

  • PDF

분산 전원 계통 연계용 보호 IED 설계를 위한 실험 연구 (Experimental Research for Design of Distributed Power System Protection IED)

  • 한철완;오성남;윤기돈;김갑일;손영익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.90-92
    • /
    • 2005
  • In this paper, we design a digital protection IED(Intelligent Electric Device) for a distributed power system in connection with power grid. The device can measure various elements for protection and communicate with another devices through network. The protection IED is composed of specific function modules: signal process module which converts analog signal from PT and CT handle algorithm to digital one; communication module for connection with another IEDs; input/output module for user-interfaces; main control module for control the whole modules. A general purpose DSP board with TMS320C2812 is used in the IED. Experiments with the power system simulator DOBLE have been made to verily the proposed hardware system.

  • PDF

Dempster-Shafer 증거 이론을 이용한 배전계통 보호도 평가 (Protection Level Evaluation of Distribution Systems Based on Dempster-Shafer Theory of Evidence)

  • 김희철;이승재;강상희;안복신;박종국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.896-898
    • /
    • 1998
  • Recent development of the digital computer and communication technology has made the concept of the adaptive protection possible, which is to adapt the operating parameters of the protective devices to the system changes, so that the best protection function can be maintained all the time. In order to achieve the adaptive protection, it is necessary to have the way to determine whether the change of the settings is needed under the certain system change or how good the current protection level is. This paper proposed the protectability index, which is a way to evaluate the protection level of the system under arbitary conditions and the operating strategy of the adaptive protection utilizing this index. It is based on an hierachical evaluation model and the evidence combination rule of the Dempster-Shafer theory.

  • PDF

Performance of Protection Systems during Catastrophic failures in Power Systems

  • Phadke Arun G.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.103-108
    • /
    • 2005
  • Catastrophic failures in power systems are rare but not uncommon events. Protection systems play an important role in the progression of events during a catastrophic failure. This paper will examine some of the historical records, and suggest possible improvements to protection systems which can have a positive impact on power system performance during catastrophic failures.

초전도 전력케이블의 계통 적용을 위한 보호계전기의 동작특성 분석 (Operational characteristics analysis of protective relay for utility application of HTS power cable)

  • 김재호;김진근;심기덕;조전욱;이승렬;윤재영;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.57-58
    • /
    • 2008
  • Recently, several kinds of superconductivity applications are implemented and evaluated in the utility power networks. The protection system for HTS(High Temperature Superconducting) power devices safe operation has not been established yet. For the protection of the HTS apparatus, a better understanding of the quench properties against fault current and appropriate protection devices are required. In this study, an algorithm of protection system is developed with respect to HTS power cable. The protection system of HTS power cable was analyzed in the simulated power system. Results obtained from simulation will provide much more decisive data in order to design a certain superconducting power device, and can give a good information for the installation in power system.

  • PDF

Development of Protection Method for Power System interconnected with Distributed Generation using Distance Relay

  • Kim, Ji-Soo;Cho, Gyu-Jung;Song, Jin-Sol;Shin, Jae-Yun;Kim, Dong-Hyun;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2196-2202
    • /
    • 2018
  • The conventional power system allowed only downstream power flow. Therefore, even if a fault occurs, only the forward current flow is considered. However, with the interest in distributed generation (DG), DGs such as Photovoltaic (PV), Wind Turbine (WT) are being connected to a power system. DGs have many advantages, but they also have disadvantage such as generation of reverse flow. Reverse flow can severely disrupt existing protection systems that only consider downstream power flow. The major problems that may arise from reverse power flow are blinding protection and sympathetic tripping. In order to solve such problems, the methods of installing a directional relay or a fault current limiter is proposed. However, this method is inconceivable because of the economics shortage. Therefore, in this paper, a distance relay installed in existing power system is used to solve the protection problem. Modeling of distance relay has been carried out using ElectroMagnetic Transients Program (EMTP), and it has been verified through simulations that the above problems can be solved by a distance relay.

An Over Current Protection Scheme for Hybrid Active Power filter

  • Lee Woo-Cheol;Chae Beom-Seok;Hyun Dong-Seok;Lee Taeck-Kie
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.571-575
    • /
    • 2001
  • A protection scheme for hybrid active power filters, which is combined shunt passive filter and small rated series active filter, is presented and analyzed in this paper. The proposed series active power filter operated as a high impedance 'k($\Omega$)' to the fundamental component when over current occurs in the power distribution system, and three control strategies are proposed in this paper. The first is the method by detecting the fundamental source current through the p-q theory, the second is the method by detecting the fundamental component of load current in Synchronous Reference Frame (SRF) and the third is the method by detecting the input voltage. When the over current occurs in the power distribution system, the proposed scheme protects the series active power filter without additional protection circuits. The validity of proposed protection scheme is investigated through experimental result for the prototype hybrid active power filter system.

  • PDF

Development of a structure analytic hierarchy approach for the evaluation of the physical protection system effectiveness

  • Zou, Bowen;Wang, Wenlin;Liu, Jian;Yan, Zhenyu;Liu, Gaojun;Wang, Jun;Wei, Guanxiang
    • Nuclear Engineering and Technology
    • /
    • 제52권8호
    • /
    • pp.1661-1668
    • /
    • 2020
  • A physical protection system (PPS) is used for the protection of critical facilities. This paper proposes a structure analytic hierarchy approach (SAHA) for the hierarchical evaluation of the PPS effectiveness in critical infrastructure. SAHA is based on the traditional analysis methods "estimate of adversary sequence interruption, EASI". A community algorithm is used in the building of the SAHA model. SAHA is applied to cluster the associated protection elements for the topological design of complicated PPS with graphical vertexes equivalent to protection elements.

A Special Protection Scheme Against a Local Low-Voltage Problem and Zone 3 Protection in the KEPCO System

  • Yun, Ki-Seob;Lee, Byong-Jun;Song, Hwa-Chang
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.294-299
    • /
    • 2007
  • This paper presents a special protection scheme, which was established in the KEPCO (Korea Electric Power Corporation) system, against a critically low voltage profile in a part of the system after a double-circuit tower outage. Without establishing the scheme, the outage triggers the operation of a zone 3 relay and trips the component. This sequence of events possibly leads to a blackout of the local system. The scheme consists of an inter-substation communication network using PITR (Protective Integrated Transmitter and Receiver) for acquisition of the substations' data, and under-voltage load shedding devices. This paper describes the procedure for determining the load shedding in the scheme and the experiences of the implementation.