• Title/Summary/Keyword: power system monitoring

Search Result 1,937, Processing Time 0.033 seconds

Thin-Plate-Type Embedded Ultrasonic Transducer Based on Magnetostriction for the Thickness Monitoring of the Secondary Piping System of a Nuclear Power Plant

  • Heo, Taehoon;Cho, Seung Hyun
    • Nuclear Engineering and Technology
    • /
    • v.48 no.6
    • /
    • pp.1404-1411
    • /
    • 2016
  • Pipe wall thinning in the secondary piping system of a nuclear power plant is currently a major problem that typically affects the safety and reliability of the nuclear power plant directly. Regular in-service inspections are carried out to manage the piping system only during the overhaul. Online thickness monitoring is necessary to avoid abrupt breakage due to wall thinning. To this end, a transducer that can withstand a high-temperature environment and should be installed under the insulation layer. We propose a thin plate type of embedded ultrasonic transducer based on magnetostriction. The transducer was designed and fabricated to measure the thickness of a pipe under a high-temperature condition. A number of experimental results confirmed the validity of the present transducer.

ESS Connected PV Monitoring System Supporting Redundant Communications (통신 이중화를 지원하는 ESS연계 태양광 모니터링 시스템)

  • Joo, Jong-Yul;Lee, Young-Jae;Oh, Jae-Chul
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • The systems associated with the ESS never stop. It runs 24 hours everyday. The system must be managed to run. The ESS system should perform normally even if the power IT equipment fails or communication failure occurs. Therefore, there is a need for a system that actively addresses, manages and controls the high precision power data of the ESS, even if a variety of failures occur. I would like to propose a power management communication unit to cope with the occurrence of communication failure. This paper also includes an integrated management system that can perform micro grid site management, maintenance and monitoring for the ESS system connected with the solar power generation facility.

Wireless Bridge Health Monitoring System for Long-term Measurement of Small-sized Bridges (중소교량의 지리적 특성을 고려한 무선 전력 및 통신 기술 기반 교량 장기 계측시스템 구축 방안 연구)

  • Tae-Ho Kwon;Kyu-San Jung;Ki-Tae Park;Byeong-Cheol Kim;Jae-Hwan Kim
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.4
    • /
    • pp.86-93
    • /
    • 2023
  • A bridge health monitoring technology is under development for the safety management of aged bridges. The bridge health monitoring technology has been developed mainly for single bridge management at a large scale, so it uses wire-based systems for power supply and data transfer. However, the wire-based systems need to be improved for the sporadically distributed small-sized bridges on local roads. This study proposed a wireless structural health monitoring system for small-sized bridges. The proposed monitoring system overcomes the limitations of wired systems by providing wireless power through solar power and utilizing LTE technology to transmit measurement data. In addition, a remote control system and power management plan were proposed to ensure the stability of the bridge measurement system. The proposed measurement system was installed on 32 bridges on fields and verified the operability by collecting 80.6% of measurement data for one year. The proposed system can support the health monitoring of aged bridges on local roads.

Development of Rooftop-mounted Smart Solar Power Generation System (IT 융합기술을 이용한 스마트 태양광 발전 시스템 연구)

  • Woo, Deok Gun;Lee, Hyo Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.504-506
    • /
    • 2022
  • The existing rooftop solar power generation systems focus mainly on the development of a fixed system because of system error along with safety problem. Accordingly, it is intended to develop a rooftop mounted smart solar power generation system by adding a solar tracking system and a monitoring system to the existing fixed rooftop solar power generation technology. It plans to develop and commercialize 'Rooftop Mounted Smart Solar Power Generation System' by applying solar tracking system, safety diagnosis and response system, abnormal diagnosis and alarm system, and external device control and monitoring systems.

  • PDF

Implementation of Failure Detecting and Monitoring System for High-Pressure Natrium Lamps and Ballasts (고압나트륨 램프와 안정기를 위한 고장 감시 시스템의 실현)

  • 오우석;이휘재;김규식;배희환
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.81-84
    • /
    • 1998
  • In this paper, we implemented this failure detecting and monitoring system for high-pressure natrium lamps and ballasts. The hall CTs of the local detecting system measure the current flowing into natrium lamps via ballasts and acertain whether the natrium lamps or ballasts are out of order or not. These test data are transmitted to the main monitoring system. So, we can see the status of the natrium lamps or ballasts promptly.

  • PDF

Implementation of a Web-based Open Architecture Monitoring System Using the Java Language (자바 언어를 이용한 개방형 구조 웹 기반 모니터링 시스템 구현)

  • 김성태;김영선;한상재;황동환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.550-550
    • /
    • 2000
  • This paper proposed a web-based open architecture monitoring system using the Java language. The proposed system can be implemented in any platform and the status of the process can be monitored in a remote station. The proposed scheme have been applied to a steam generator level controller for a nuclear power plant. The result shows the feasibility of the proposed system.

  • PDF

Study on analog-based ex-core neutron flux monitoring systems of Korean nuclear power plants for digitization

  • Kim, Young Baik;Vista, Felipe P. IV;Chong, Kil To
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2237-2250
    • /
    • 2021
  • The analog-based Ex-core Neutron Flux Monitoring System (ENFMS) in Korean Nuclear Power Plants (NPPs) has been performing its intended functions successfully for a long time. On the other hand, the primary concern with the extended use of analog systems is the aging effect, such as mechanical failures, environmental degradation, and obsolescence. The transition to a digital-based Man-Machine Interface Systems (MMIS) in Korea and other countries has been accelerating, but some systems are still analog-based IC systems, such as the ENFMS in APR1400 NPPs. Digitalized ENFMS can become a reality using computers and microprocessors owing to the progress in digital electronics and information technology. This paper presents the result of the first phase of the research on the digitalization of the ENFMS signal processing electronics for NPPs operated or produced in Korea. It has two main parts: (1) review engineering bases of ex-core neutron flux monitoring system, including nuclear engineering, instrumentation techniques, and analog and digital signal processing techniques, and (2) analysis of analog signal processing electronics of ENFMS for OPR1000 and APR1400 power plants. They are prerequisite to the second phase of the research which is the detailed implementation of the digitalization.

DTS-based Temperature Monitoring and Analysis of Battery Cell Deterioration Characteristics by Temperature Condition (DTS 기반 온도 감시 및 온도 조건에서의 배터리 셀 열화 특성 분석)

  • SoonJong, Kwon;Soo-Yeon, Kim;Jin, Hwang;Sang-Kyun, Woo;Bong-Suck, Kim
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.2
    • /
    • pp.143-149
    • /
    • 2022
  • As ESS safety issues increase recently, there is a need to more precisely monitor the temperature of the ESS. In this paper, DTS technology for temperature monitoring of ESS batteries is introduced and the temperature measurement principle is explained. The temperature of the battery module is measured using the DTS system, and the thermal deviation between battery cells inside the battery module is analyzed. In order to analyze how thermal imbalance affects the charging and discharging performance of the battery, an accelerated degradation test was conducted. Cycle life characteristics analysis, battery surface temperature change, and AC impedance characteristics were conducted to analyze how the performance of battery cells differs according to temperature conditions.

Design of Data Center Environmental Monitoring System Based On Lower Hardware Cost

  • Nkenyereye, Lionel;Jang, Jongwook
    • Journal of Multimedia Information System
    • /
    • v.3 no.3
    • /
    • pp.63-68
    • /
    • 2016
  • Environmental downtime produces a significant cost to organizations and makes them unable to do business because what happens in the data center affects everyone. In addition, the amount of electrical energy consumed by data centers increases with the amount of computing power installed. Installation of physical Information Technology and facilities related to environmental concerns, such as monitoring temperature, humidity, power, flood, smoke, air flow, and room entry, is the most proactive way to reduce the unnecessary costs of expensive hardware replacement or unplanned downtime and decrease energy consumed by servers. In this paper, we present remote system for monitoring datacenter implementing using open-source hardware platforms; Arduino, Raspberry Pi, and the Gobetwino. The sensed data displayed through Arduino are transferred using Gobetwino to the nearest host server such as temperature, humidity and distance every time an object hitting another object or a person coming in entrance. The raspberry Pi records the sensed data at the remote location. The objective of collecting temperature and humidity data allows monitoring of the server's health and getting alerts if things start to go wrong. When the temperature hits $50^{\circ}C$, the supervisor at remote headquarters would get a SMS, and then they would take appropriate actions to reduce electrical costs and preserve functionality of servers in data centers.