• 제목/요약/키워드: power system monitoring

검색결과 1,937건 처리시간 0.035초

웹 기반 풍력발전 모니터링 시스템 개발에 관한 연구 (A Study on the Development of the Web-based Monitoring System for the Wind Turbine Powers)

  • 김인수;김성식;최영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1147-1148
    • /
    • 2006
  • The increase of exhaust gas which is caused by with the industry activity which follows in the Industrial Revolution of the human being has had an influence on the globe climate system so that causes the problem of the greenhouse effect. As a comprehensive countermeasures, it has been prompted to save energy, build a structure environmentally friendly and use renewable energy sources that are continually replenished by nature-the sun, the wind, the Earth's heat, and plants. In addition, new technologies that turn these fuels into usable forms of energy-most often electricity, but also heat, chemicals or mechanical power have been applied actively to the social infrastructure. Therefore, there should be methods to manage forms of renewable energy effectively and securely. This paper proposes the web-based monitoring system for the wind power system of these methods and introduces the real web-based monitoring system installed in Daegwallyeong.

  • PDF

발전용 고온 배관의 점검 및 실시간 변위감시 기술 (Technology of Inspection and Real-time Displacement Monitoring on Critical Pipe for Power Plant)

  • 현중섭;허재실;조선영;허정열;이성기
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.1177-1186
    • /
    • 2009
  • High temperature steam pipes of thermal power plant are subject to a severe thermal range and usually operates well into the creep range. Cyclic operation of the plant subjects the piping system to mechanical and thermal fatigue damages. Also, poor or malfunctional supports can impose massive loads or stress onto the piping system. In order to prevent the serious damage and failure of the critical piping system, various inspection methods such as visual inspection, computational analysis and on-line piping displacement monitoring were developed. 3-dimensional piping displacement monitoring system was developed with using the aluminum alloy rod and rotary encoder sensors, this system was installed and operated on the high temperature steam piping of "Y" thermal power plant successfully. It is expected that this study will contribute to the safety of piping system, which could minimize stress and extend the actual life of critical piping.

전력간선에서의 전자파 장애를 고려한 원칩형 누설전류 원격 검출단말기의 개발 (An Development of Leakage Current Sensing Module of the System on Chip Type Under Consideration of Electromagnetic Interface in Power Trunk Line)

  • 김동완;박지호;박성원
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.377-384
    • /
    • 2009
  • In this paper, leakage current sensing module of SoC(System on Chip)type and real time monitoring system under consideration of electromagnetic interface in power trunk line are developed. The first, leakage current sensing module of SoC type under consideration of electromagnetic interface is developed, and the developed sensing module of SoC type is composed of leakage sensing part, power supply part, interface part, communication part, AD(Alternating current to Direct current)convert part and amplification part. And also the electromagnetic compatibility is evaluated by conduction and radiation of EMI(Electromagnetic Interference) for developed sensing module. The developed system can have confidence, stability and do energy saving under mixed electric circumstance of the low voltage communication device and high voltage equipment. The second, the real time remote monitoring system is developed using designed wire and wireless communication module with leakage current sensing module of SoC type. The developed real time remote monitoring system can monitor sensing state, occurrence state of leakage current and alarm for each step etc.. And the device configuration, PCB layout for leakage current sensing module of system on chip type and the experiment configuration in consideration of EMI are presented. Also the measurement results of conduction and radiation for EMI are presented.

CNC 공작기계의 절삭력 감지를 위한 주축모터의 역률 및 마찰특성에 관한 연구 (Study on Spindle Motor's Power-Factor and Frictional Characteristics For Cutting Force Monitoring in a CNC Machine)

  • 홍성함;이병휘;허건수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.141-146
    • /
    • 2002
  • Real-time monitoring and control of the cutting force is essential for unmanned cutting process. Although the cutting force can be measured directly using tool dynamometers, their implementation is not feasible in industry due to high cost. Alternative approach is the cutting force estimation based on spindle drive models, but it requires the knowledge of their characteristics with the spindle speed variation. This paper investigates the power-factor and frictional characteristics of three-phase induction motors and determines its characteristics below and above the base speed, respectively. In order to realize the proposed cutting force monitoring system, a stand-alone DSP board was utilized. Its monitoring and control performance is evaluated in a CNC lathe.

  • PDF

이산웨이블릿을 이용한 전력외란 측정 시스템 (Power disturbance measurement system using discrete wavelet transform)

  • 이진목;김홍균;최재호;이상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.177-181
    • /
    • 2003
  • Need of power stability, reliability is increased, as using of sensitive: nonlinear load are increasing. Therefore, Power Quality Problems become the center of public interest. Many kinds of algorithms have been studied for monitoring of Power Quality Problems. Monitoring algorithms of using RMS, FT and the others are easy to applicate to system. But, it is not enough to monitor all of Foyer. Quality problems. Wavelet Transform is more proper to applicate. so, This paper presents measurement system using discrete wavelet transform.

  • PDF

전력 모니터링 시스템의 개발 (Development of Electronic Power Monitoring System)

  • 박성재;윤지근;김상봉
    • 동력기계공학회지
    • /
    • 제7권1호
    • /
    • pp.42-50
    • /
    • 2003
  • 최근의 배전반 설비의 고성능, 안정성, 신뢰성은 전기에너지의 사회적 욕구로 요구되고 있다. 본 논문에서는 전력품질에 관한 정보를 수집하고 통합 모니터링과 설비의 보호, 그리고 다양한 장치들을 제어할 수 있는 전력 모니터링 시스템의 개발에 대하여 고려하고자 한다. 전력품질 모니터링을 통하여 수집된 정보는 시스템의 효과적인 운용과 사용상의 신뢰성을 개선시킨다. 본 시스템은 크게 하드웨어부와 소프트웨어부로 구성된다. 하드웨어부는 원칩 마이크로 프로세서(Intel 80C196KC)를 사용한 측정과 제어, 통신 그리고 입/출력을 담당하는 다기능 인디케이터와 컨트롤러로 구성된다. 다양한 기능의 모니터링, 데이터베이스와 제어를 PC상에서 구현하기 위한 소프트웨어부는 사용자 그래픽 인터페이스(GUI) 기반의 비주얼 프로그래밍을 사용하여 개발되었다.

  • PDF

광역 전력계통 감시시스템 구축 및 실증 (Building and Actual Proving K-WAMS in Korea Power Grid)

  • 김상태;김지영;송완석;장수형;문영환;김태현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.175_176
    • /
    • 2009
  • K-WAMS based on i-PIU as a synchro-phasor data acquisition device using GPS can treat a monitoring and evaluation of wide area power system to detect a various symptoms of wide area disturbances and prevent large blackout. This paper introduced the development of K-WAMS such as WAMS(Wide Area Monitoring System).

  • PDF

무선통신기술을 적용한 도시철도 전력설비의 상태모니터링 (Condition Monitoring of the Power Facilities appling to the Wireless Communications in Urban Rail Transit)

  • 김도윤;정호성;박영;박현준;박영재;김성태
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.406-410
    • /
    • 2009
  • Power facilities of urban rail transit substation is deterioration, and endurance limitation is coming, so urban rail transit facilities should take any necessary measure for maintenance and repair. In this paper proposes online monitoring system using the wireless communications for the urban rail transit. This system is constructed various departments; such as sensor, measurement, data communication, host computer, and power departments. It is designed to collect and save AI (Analog Input) information of the power facilities, and to analyze and display them. As a result, it is possible to prevent from any unexpected power cuts and monitor my abnormalities in real time, and to collect accumulated data for creating a better management system.

  • PDF

IEC61850 기반 디지털 변전시스팀에서의 PDMS 적용 방안에 관한 연구 (A study for PDMS Application Scheme of Digital S/S with IEC61850 Base)

  • 이동철;김희수;배을록;민병운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.78-82
    • /
    • 2006
  • The Partial Discharge Monitoring System is technology which is available to measure & analysis the partial discharge of Power equipment. This technology is in the limelight as a pre-forecast system of equipment defect but there are some problems like no protocol standard, layered network management and the limitation of physical size. This paper presents whole system structure includes engineering centers, LN(Logical Node) to apply PDMS for, base-digital substation system, ICE61850 compatible Condition Monitoring &Diagnosis (CMD), Local Unit(LU), Intelligent Electronic Device (IED) for the solution scheme of these limitations.

  • PDF

50kW 계통연계형 태양광발전시스템의 성능특성 결과분석 (Performance Results and Analysis of 50kW Grid-Connected PV System)

  • 소정훈;정영석;유병규;황혜미;유권종;최주엽
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2006년도 전력전자학술대회 논문집
    • /
    • pp.219-221
    • /
    • 2006
  • This paper presents the performance results of 50kW grid-connected PV (Photovoltaic) system for monitoring periods. Form these performance monitoring results, the PV system performance has been evaluated and analyzed for component perspective (PV array and power conditioning unit) and global perspective (system efficiency, capacity factor, and electrical power energy and power quality etc.).

  • PDF