• 제목/요약/키워드: power station

검색결과 1,325건 처리시간 0.036초

상용 기성부품을 이용한 O-RAN 호환 기지국 시스템 구현 (Implementation of an O-RAN-Compliant Base Station System Using Commercial Off-the-Shelf Components)

  • 도홍흠;장중봉;최승원;이태훈
    • 디지털산업정보학회논문지
    • /
    • 제18권1호
    • /
    • pp.11-24
    • /
    • 2022
  • Open Radio Access Network (O-RAN) standard has been proposed to separate the baseband signal processing unit from the Radio Frequency (RF) unit at base station system mainly for reducing the cost of base station systems through open-source interfaces between the two units. To satisfy the performance metrics in various scenarios, several fronthaul functional split options were presented by O-RAN. Amongst these options, the split option 7-2x is widely adopted in practical applications due to its excellent trade-off between the required bandwidth and RU overhead. In this paper, we present a hardware implementation of a base station system that is compliant with the Category B of O-RAN split option 7-2x. It consists of O-DU and O-RU implemented with a commercial off-the-shelf Digital Signal Processor and RF transceiver, respectively. The performance of the proposed base station system is evaluated in terms of Bit Error Rate and received signal power as well as the required fronthaul bandwidth. Through various experimental tests, we have observed that the proposed system reduces the fronthaul bandwidth nearly by 89.7% compared to the conventional system that dose not employ the O-RAN standard.

안면도 기후변화감시소의 여름철 PM2.5 OC와 EC 분포 특성 및 배경대기 구분 (Distribution Characteristics and Background Air Classification of PM2.5 OC and EC in Summer Monsoon Season at the Anmyeondo Global Atmosphere Watch (GAW) Regional Station)

  • 함지영;이미혜;류상범;이영곤
    • 대기
    • /
    • 제29권4호
    • /
    • pp.429-438
    • /
    • 2019
  • Organic carbon (OC) and elemental carbon (EC) in PM2.5 were measured with Sunset Laboratory Model-5 Semi-Continuous OC/EC Field Analyzer by NIOSH/TOT method at Anmyeondo Global Atmosphere Watch (GAW) Regional Station (37°32'N, 127°19'E) in July and August, 2017. The mean values of OC and EC were 3.7 ㎍ m-3 and 0.7 ㎍ m-3, respectively. During the study period, the concentrations of reactive gases and aerosol compositions were evidently lower than those of other seasons. It is mostly due to meteorological setting of the northeast Asia, where the influence of continental outflow is at its minimum during this season under southwesterly wind. While the diurnal variation of OC and EC were not clear, the concentrations of O3, CO, NOx, EC, and OC were evidently enhanced under easterly wind at night from 20:00 to 8:00. However, the high concentration of EC was observed concurrently with CO and NOx under northerly wind during 20:00~24:00. It indicates the influence of thermal power plant and industrial facilities, which was recognized as a major emission source during KORUS-AQ campaign. The diurnal variations of pollutants clearly showed the influence of land-sea breeze, in which OC showed good correlation between EC and O3 in seabreeze. It is estimated to be the recirculation of pollutants in land-sea breeze cycle. This study suggests that in general, Anmyeondo station serves well as a background monitoring station. However, the variation in meteorological condition is so dynamic that it is primary factor to determine the concentrations of secondary species as well as primary pollutants at Anmyeondo station.

석탄 화력발전소에서 발생하는 미연분의 특성분석 및 저감방법 (Characteristics of Carbonaceous Particles Derived from Coal-fired Power Plant and Their Reduction)

  • 박호영;김영주;유근실;김춘근;김동훈
    • 대한환경공학회지
    • /
    • 제28권10호
    • /
    • pp.1065-1073
    • /
    • 2006
  • 영흥 화력발전소 1호기 보일러에서 발생된 미연분은 석탄 회의 재활용 및 보일러 효율 측면에서 문제를 일으키고 있었다. 본 연구에서는 미연분 및 사용 석탄의 특성과 현장의 연소조건 분석을 수행하고 보일러 운전조건을 변경하므로서 보일러에서 발생되는 미연분을 저감하고자 하였다. 미연분의 물리, 화학적 분석 결과 대부분 중공(中空)형태의 Cenosphere와 뭉쳐진(Agglomerated) 형태의 Soot로 이루어져 있었다. 영흥 화력발전소에서 사용중인 6개 탄종에 대하여 Tar 및 Soot의 발생 가능량을 CPD(Chemical Percolation Devolatilization) 모델을 이용하여 조사한 결과, Sanseo, Ensham, Elk Valley 탄의 경우 그 발생 가능량이 비교적 적었으며 Peabody, Arthur, Shenhua 탄은 높았다. 영흥 화력발전소 1호기 보일러의 각 미분탄 공급관에서의 미분탄 공급량을 측정하였는데 코너 별로 공급되는 몇몇 버너에서 미분탄이 편중되어 공급되고 있음을 알 수 있었다. 이에 따라 soot가 주성분인 미연분의 산화율을 증가시키기 위하여 과잉공기량을 증가시키고 산화제와의 혼합정도를 높이기 위하여 SOFA(Separated Over Fire Air)의 yaw 각도를 적절히 조절함으로서 미연분의 발생량을 현저히 감소시킬 수 있었다.

발전소 제어시스템 기본 스테이션 기능 검증 (Functional Test of A Station of Control System for Power Plant)

  • 변승현;박두용;임익헌
    • 전자공학회논문지SC
    • /
    • 제48권4호
    • /
    • pp.25-32
    • /
    • 2011
  • 국내 전력의 수요증가로 인해 전력산업에서 신경망 역할을 하는 I&C(Instrumentation & Control)의 중요성이 날로 증가하고 있으며, 외국 선진 제작사의 기술 보호로 제어 시스템의 국산화가 요구되고 있는 상황이다. 이러한 상황에서 500MW급 초임계압 표준 석탄화력 발전소에의 실증 적용을 목표로 국산 통합 감시 제어시스템 개발 연구가 진행되고 있다. 개발하는 통합 감시 제어시스템은 발전설비의 중요성으로 인해 개발과정이나 개발 후 발전 설비에 적용되기 전에 시스템의 기능 및 신뢰성 등의 검증이 요구되고 있다. 또한 전력수요의 증가로 인해 제어시스템 설치 및 시운전 기간의 충분한 확보가 어려운 시점에서, 향후 실증 적용시 시행착오를 줄이기 위해 제어 시스템의 검증은 필수적이다. 본 논문에서는 개발한 제어 시스템의 기본 스테이션에 대해 기능 검증한 사례를 소개한다.

기지국용 제어전원으로 사용가능한 위상제어 직렬공진형 컨버터 시스템 (Phase Controlled Series Resonant Converter System for Control Power Supply in a Base Station)

  • 지준근;임영하
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.181-183
    • /
    • 2003
  • In this paper, phase controlled series resonant converter(PCSRC) system for control power supply in base station is suggested. PCSRC system is robust to load variations because it is POSR(parallel output series resonant) type. And it provides stable output voltage by changing phase angle of MOSFET switches to input voltage variations. Firstly, operation analysis about suggested series resonant converter system was carried. Then Computer simulations using PSIM were carried to prove characteristics of suggested system.

  • PDF

An Advanced Simulation Model for Brushless DC Motor Drives

  • Lee B. K.;Ehsani M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.390-394
    • /
    • 2001
  • A dynamic simulation model for the brush less dc (BLDC) motor drives using Matlab is presented. In this model, an entire BLDC motor drive, including power conversion unit, BLDC motor, and speed/torque control system, is investigated. Especially, the PWM inverter is modeled using switching function concept, so that the detailed voltage and current waveforms, such as line-to-line voltages, inverter input current, ac line current, and switch/diode currents, can be obtained and average/rms ratings of the components can be easily calculated. Also, the proposed model is made into modular blocks and it can be easily extended to other ac motor applications with a little modification. The detailed modeling method is explained and its actual implementation is described. The validity of the proposed model is verified by various simulation results.

  • PDF

Overview of State of the Art of Reduced Parts Converter Topologies for Adjustable Speed Drives

  • Lee B. K.;Ehsani M.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.395-399
    • /
    • 2001
  • In this paper, various reduced parts converter topologies and control strategies for power factor correction and motor control are reviewed and systematic design methodology is developed. From this investigation, the converter topologies could be mainly categorized into cascade type and unified type. The detailed operational principles are examined and the performance comparison is derived to illustrate merits and limitations of the converters. Simulation results are provided to help the better understanding of the theoretical description and several experimental results are presented on prototype induction motor better brush less dc (BLDC) motor drives, along with cascade and unified type converters.

  • PDF

비상디젤발전기 신뢰도에 대한 베이즈추정 (Bayes Estimate for the Reliability of Nuclear-Power Plant Emergency Diesel Generator)

  • 심규박;류부형
    • 품질경영학회지
    • /
    • 제25권3호
    • /
    • pp.108-118
    • /
    • 1997
  • A commercial nuclear power station contains at least two emergency diesel generates(EDG) to control the risk of severe core demage during the station blackout accidents. Therefore the reliability of the EDG's to start and load-run on demend must be maintained at a sufficiently high level. Until now, a simple assessment of start and load-run success rates was used to calculate the EDG's reliability. However, this method has been found to contain many defects. Recently, the work of Martz et al.(1996) proposed the use of the Bayes estimator to find the EDG's reliability. In this paper, we will propose confidence interval for the Bayes estimator, compare the above two methods and, using practical examples, illustrate why the Bayes estimator method is more reasonable in our situation.

  • PDF

한반도 풍력자원의 시공간적 특성 분석 (The spatial-temporal characteristics for wind power resources on the Korean Peninsula)

  • 이화운;김민정;김동혁;김현구;이순환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.331-332
    • /
    • 2008
  • Wind energy issued as most spotlight general energy by excellence of actuality as well as economical efficiency, solving environmental problem which caused by creating the energy and possibility of eternal production. Accordingly, government is at the stage of corresponding level by requesting development of new technology to the developed countries as a part of national key industries. The grievous situation from such a rapid movement is meteorological comprehension and assessment as well as the problem of estimation exactness about the wind. In this study, we use the regional meteorological station data, automatic weather station data and QuikSCAT SeaWinds data.

  • PDF

수력발전소 건물 소음저감대책 연구 (A Study on the Noise Reducing Method for HydroPower Station Building)

  • 김기원;조성수;이연주;박태진;이용훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.58-60
    • /
    • 2008
  • In this paper, In this investigation we measured and evaluated effects to residential area as result of noises caused by building vibration when the turbine of hydro-electric power station runs, and establishes the best plan of soundproof for that area. Furthermore, we analyzed differences between estimated noises and actual noises and its causes before constructing the soundproofing panels so that it helps to start building the soundproofing panels and similar constructions in the future.

  • PDF