• Title/Summary/Keyword: power station

Search Result 1,325, Processing Time 0.032 seconds

The study on Harmonic Current Generated on Power Supply Station in(for) Conventional line and The Review on Effect of facility reducing Harmonic Current. (기존선 변전소에서의 고조파 발생현황과 저감설비 설치 효과 검토)

  • Park Sang-Ock;Lee Jong-Woo;Kwon Sam-Young;Lee Chang-Moo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1309-1315
    • /
    • 2004
  • The harmonic current originated from electric cars will be cause of electromagnetic interference along adjacent communication cables and troubles with signaling. It will also cause overheating in power capacitor and malfuction in protection relay. Therefore, it brought actual measurement of harmonic current by each operation mode. Because the result exceeded the value prescribed by Korea Electric Power Corporation, we constructed facilities reducing harmonic current on overloaded part at each power supply station located in conventional line (Guro, Kyungsan, and Milyang) as an optimal alternative. Then, this study compared and analyzed the reducing effect before and after constructing facility.

  • PDF

A Case study on the plan for the ESC integrating optimized train operation system for Fire & power failure accident in subway (도시철도 화재$\cdot$단전시 최적 열차운행을 위한 통합운영체계 구축방안에 관한 연구)

  • Kim Young-Wook;Choi Se-Wan;Kim Young-Kyu
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1185-1192
    • /
    • 2004
  • Recently heavy traffic is getting worse because increasing population of transportation in urban area. In order to solve this problem. subway is realized with high speed, high density, highly efficiency. When fire accident happened in Dae-Gu subway in February 2003, there happened loss of people and lots of damage because of not being able to control even though fire alarm which was set up in the station rang. This thesis has constructed a simulation integrating operation system using a Database construction, operating program analysis in order to build up the most efficient train operation system. The result of simulation integrating operation system with emergency virtual situation like station and train fire, train failure, power line failure, all trains running on the rail were secured safety by train operation control system. With integrating operation of each train control system, train system, power system, machine facility system, the most efficient integrating operation system should have been constructed at the time the subway fire and power failure broke out.

  • PDF

A Study on the Power Station Application and Performance Evaluation of 10㎿ grade Intelligent Digital Governor (10㎿급 인텔리전트 디지털 가버너의 현장적용 및 성능평가에 관한 연구)

  • 조성훈;장민규;전일영;이성근;김윤식
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.314-317
    • /
    • 2002
  • This paper present a methods for performance evaluation of digital governor and we treat the way to reduce the trial and error when the developed digital governing system is applied to station. The parameters of the model are estimated using input-output data, the model adjustment technique and a genetic algorithm(GA). To verify validity of the completed model, the comparision model and real output signals have been carried out. The developed digital governing system is applied to Sumjingang hydro-power plant, Korea Hydro Nuclear Power Corporation, it has replaced mechanical governing system. Test was performed in order to demonstrate the performance evaluation of the digital governor parameters.

  • PDF

Power Control of Femto Base Station for Protecting Macrocell Users (매크로셀 사용자 보호를 위한 펨토셀 기지국의 전송전력 제어)

  • Jeong, Dong Geun;Kim, Yu Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38A no.10
    • /
    • pp.865-873
    • /
    • 2013
  • In the cellular networks adopting femtocells, the macrocell users can suffer from severe interference by the femtocells. In this paper, we propose a distributed transmission power control scheme for femtocells to protect macrocell users. With the proposed scheme, when a macrocell user experiences outage due to severe interference, it informs the interfering femtocell base station (BS) of the outage occurrence, via the macrocell BS. Then, the femtocell BS reduces the transmission power to protect the macrocell user. The proposed scheme does not require too much control information among the macrocell BS, the macrocell users, and the femtocell BS. Moreover, the computational complexity in femtocell BS is very low. By using simulation, we show that the performance of the proposed scheme is good enough to use in practice, in spite of its simplicity.

A Basic Study on a New Type Particulate Emission Control Means of a Power Station Using a Micro-Gap and a Pulse Discharge (Micro-Airgap Discharge Phenomena) (초미소간격(超微小間隔)과 극단(極端)펄스방전(放電)을 이용(利用)한 미연소탄소립자(未燃燒炭素粒子) 소각제거기술(燒却除去技術) 개발기초연구(開發基礎硏究)(I) (초미소간격(超微小間隔)의 방전현상(放電現象)))

  • Moon, Jae-Duk;Shin, Soo-Youn
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.605-608
    • /
    • 1993
  • Breakdown characteristics of a small rod-to-rod microairgap has been studied for obtain an optimum breakdown voltage and an airgap spacing to be used as an emission control means by the electrical arc-burning unburnt carbon particulates exhausted from a power station burner. It is found that the breakdown voltage at the rod-to-rod airgap spacing in the rang of $1{\sim}100{\mu}m$ decreased with decrease in the rod-to-rod airgap spacing. And there were no minimum breakdown voltage on a $V_b$-Pd characteristics which is known as the minimum voltage in Paschen's law in air atmosphere. Breakdown voltages of the airgap at the constant airgap spacing were $V_{b-dc}>V_{b-ac}>V_{b-pulse}$, and it was lowest for the pulse voltage applied. As a result, it is found that a pulse power was one of effective power compared with dc or ac to be used as such an unburnt carbon particulate emission control means and the airgap spacing became to several tens ${\mu}m$, then the breakdown voltages were down to several handreds voltages.

  • PDF

Design of a 2.6 GHz GaN-HEMT Doherty Power Amplifier IC for Small-Cell Base Station Systems (Small-Cell 기지국 시스템을 위한 2.6 GHz GaN-HEMT Doherty 전력증폭기 집적회로 설계)

  • Lee, Hwiseob;Lim, Wonseob;Kang, Hyunuk;Lee, Wooseok;Lee, Hyoungjun;Yoon, Jeongsang;Lee, Dongwoo;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.2
    • /
    • pp.108-114
    • /
    • 2016
  • This paper presents a 2.6 GHz Doherty power amplifier IC to enhance the back-off efficiency. In order to apply to small-cell base stations, the Doherty power amplifier was fabricated using GaN-HEMT process for high power density. In addition, the implemented Doherty power amplifier was mounted on a QFN package. The implemented GaN-HEMT Doherty power amplifier was measured using LTE downlink signal with 10 MHz bandwidth and 6.5 dB PAPR for verification. A power gain of 15.8 dB, a drain efficiency of 43.0 %, and an ACLR of -30.0 dBc were obtained at an average output power level of 33.9 dBm.

Reconstruction of CIGRE benchmark model for DC Transmission (직류전송을 위한 CIGRE benchmark 모델의 재구성)

  • Wang H.J.;Choi J.H.;Kim C.K.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.446-450
    • /
    • 2003
  • This paper makes more stronger than original model about sending station fault and saves total construction cost to replace established six-pulse bridge by each six thyristor for DC-transmission. Also, varying of controller for sending station has a robust characteristics for harmonics and unbalanced faults. This paper is verified by simulation using EMTDC program. Comparing with the results of original model, this paper is proved superiority.

  • PDF

Analysis of Vibration of apply to drive pump with inverter (인버터 적용 펌프모타의 부하운전별 진동해석)

  • Hwang, Jin-Yeol;Kim, Ki-Won
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1131-1132
    • /
    • 2011
  • For the purpose to flow control of pump in booster pump station, nonlinear-load inverter equipment is being introduced. While inverter equipment has the advantage of power-ratio savings and volume control, due to the vibration of pump and motor, secondary breakdown may occur Purpose in this paper is reliable facility operation by providing optimal operationg standards through vibration analysis of apply to drive pump with inverter in long-term in booster pump station.

  • PDF

Station Collocation of Geostationary Spacecraft Via Direct Control of Relative Position (상대위치 직접 제어를 통한 정지궤도 위성의 Collocation에 관한 연구)

  • Lee, Jae-Gyu;No, Tae-Su
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.5
    • /
    • pp.56-64
    • /
    • 2006
  • Station collocation of closely placed multiple GEO spacecraft is required to avoid the problem of collision risk, attitude sensor interference and/or occultation. This paper presents the method of obtaining the orbit correction scheme for collocating two GEO spacecraft within a small station-keeping box. The relative motion of each spacecraft with respect to the virtual geostationary satellite is precisely expressed in terms of power and trigonometry functions. This closed-form orbit propagator is used to define the constraint conditions which meet the requirements for the station collocation. Finally, the technique of constrained optimization is used to find the orbit maneuver sequence. Nonlinear simulations are performed and their results are compared with those of the classical method.

A channel assignment scheme for reducing call blocking rate in DS-CDMA cellular systems (DS-CDMA 셀룰라 시스템에서 호 차단률 개선을 위한 채널 할당 방식)

  • 전형구;황선호;권수근;강창언
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.5
    • /
    • pp.1075-1082
    • /
    • 1997
  • In this paper, we propose a channel assignment scheme for reducing call blocking rate in a base station(BS) of DS-CDMA cellular systems. The proposed scheme can e applied to the case where the capacity of reverse radio link is enough, but not are the available traffic channels performing the digital modulation and demodulation functions between a mobile station and the base station. The proposed scheme takes advantage of the feature of soft handoff in which a mobile station keeps its communication link even if one of the two communication links is released. The scheme estimates the mean and variance of the received power level measured at the base station before assigning a traffic channel for a new call request. The BS makes decision based on the estimated balues whether the new call request will be accepted or not. If it is decided that the capacity of reverse radio link is enough, but all traffic channels are not available, then the BS increases the soft handoff parameter T_DROP to release the traffic channels of mobile stations loactedin soft handoff area. The BS assigns the released traffic channel to anew call or a handoff call. The performance of the proposed channel assignment scheme is evaluated by computer simulation. The results show that the call blocking rate for new calls and handoff calls is reduced.

  • PDF