• 제목/요약/키워드: power station

검색결과 1,325건 처리시간 0.023초

Revenue Maximizing Scheduling for a Fast Electric Vehicle Charging Station with Solar PV and ESS

  • Leon, Nishimwe H.;Yoon, Sung-Guk
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권3호
    • /
    • pp.315-319
    • /
    • 2020
  • The modern transportation and mobility sector is expected to encounter high penetration of Electric Vehicles (EVs) because EVs contribute to reducing the harmful emissions from fossil fuel-powered vehicles. With the prospective growth of EVs, sufficient and convenient facilities for fast charging are crucial toward satisfying the EVs' quick charging demand during their trip. Therefore, the Fast Electric Vehicle Charging Stations (FECS) will be a similar role to gas stations. In this paper, we study a charging scheduling problem for the FECS with solar photovoltaic (PV) and an Energy Storage System (ESS). We formulate an optimization problem that minimizes the operational costs of FECS. There are two cost and one revenue terms that are buying cost from main grid power, ESS degradation cost, and revenue from the charging fee of the EVs. Simulation results show that the proposed scheduling algorithm reduces the daily operational cost by effectively using solar PV and ESS.

CDMA 신호의 Code Domain Power 모듈 개발 (Development of Code-Domain Power module for CDMA signal)

  • 이영교
    • 디지털산업정보학회논문지
    • /
    • 제4권1호
    • /
    • pp.17-24
    • /
    • 2008
  • This paper describes the measurements that provide a characterization of the code-domain channels of a CDMA base station transmitter. One of the measurements, called code-domain power(CDP), provides the distribution of power in the code domain channels. This measurement can be used to verify that the various channels are at expected power levels and to determine when one code channel is leaking energy into the other code channels. We develop module of CDP measurement in the CDMA system.

상이형전자계산기에 의한 영월.부평간 송전계통의 과도안전도 해석 (Transient stability analysis of the Yongwol.Bupyong power system by electronic analog computer techniques)

  • 한만춘
    • 전기의세계
    • /
    • 제15권1호
    • /
    • pp.14-19
    • /
    • 1966
  • Transient stability analysis of Yongwol-Bupyong power system, which contains Yongwol steam power station, the largest one in Korea, was undertaken by using the Yonsei 101 Analog computer. The critical switching time and phase angle for the present 150MW power flow to be stable were found. And the transient stability power limit for the system was also found. It is concluded that the system becoms unstable if the power flow increases much more than 151MW.

  • PDF

저전력 RMIMS 무선 터미널을 위한 새로운 움직이는 이동 기지국 시스템 구조 (1부 : MMBS 일반사항, 클러스터링 및 신호절차) (A New Moving Mobile Base Station (MMBS) Scheme for Low Power RMIMS Wireless System (PARTI: MMBS general issues, clystering and signalling Procedures))

  • 박수열;고윤호;유상조;김성대
    • 한국통신학회논문지
    • /
    • 제24권12B호
    • /
    • pp.2298-2319
    • /
    • 1999
  • 본 논문에서는 최근 들어 본격적인 연구개발이 활성화되고 있는 무선 데이터 통신서비스를 근간으로 한 미세 정보 감시 시스템(RMIMS : radio interfaced micro information monitoring system or MICROS: micro information and communication remote object-oriented system)에 대한 QoS(quality of service)를 보장하는 새로운 움직이는 기지국(MMBS: moving mobile base station) 서비스 방법을 제안하였다. 미세정보 감시시스템은 독립된 전원 장치 형태로 감시 대상 지역에 영구적으로 혹은 반 영구적으로 배치되므로 매우 저 전력의 시스템 요구 사항을 가진다. 또한 이동서이 작고, 비교적 비 실시간 트래픽 특성과 터미널의 배치 영역에 비해 터미널 수가 작은 특성을 가진다. 상향링크(uplink) 방향의 전송거리가 작고, 특정 일부 지역에 환경오염감시, 안전감시, 재난감시, 군사적인 목적 등 응용서비스에 따라 배치되는 RMIMS 터미널을 서비스하기 위해서는 기존의 셀룰라 망에서 사용되는 고정위치 기지국 방식은 경제성 및 실현성을 제공할 수 없다. 이러한 경우에 RMIMS 터미널들에 대한 정보 수집 데이터 망 (network) 서비스를 위하여 이중 무선 인 股嶽決?dual wireless network interface)을 가지면서 IS-MMBS(in-service MMBS), BS-MMBS(background scanning MMBS)를 사용하는 서비스 구조를 통하여 RMIMS 터미널들에 QoS를 보장하는 무선 데이터 서비스를 제공하는 방법 및 절차들을 제안하였다.

  • PDF

다이나믹 펨토셀 네트워크에서 커버리지와 데이터 부하 균형을 고려한 기지국의 파워 조절 분산 알고리즘 (A Distributed Power Control Algorithm for Data Load Balancing with Coverage in Dynamic Femtocell Networks)

  • 신동훈;최성희
    • 정보과학회 컴퓨팅의 실제 논문지
    • /
    • 제22권2호
    • /
    • pp.101-106
    • /
    • 2016
  • 셀룰러 시스템을 기반으로 하는 펨토셀 네트워크는 실내 환경에서 대용량 데이터 전송을 위한 기술로 주목 받고 있다. 본 연구에서는 다수의 펨토 기지국을 배치하여 서비스를 제공하는 실내 환경에서 커버리지 문제와 데이터 전송 부하 문제를 동시에 고려하는 기지국의 파워 조절 분산 방법을 제안한다. 사용자의 데이터 사용량은 시간과 장소에 따라 지속적으로 변화하기 때문에 기지국의 데이터 전송 부하를 효과적으로 분배하는 동적 파워 조절 방법이 요구된다. 또한, 대규모 시설에 설치되어 있는 펨토셀 네트워크 시스템을 효율적으로 운영하기 위해서는 기지국의 파워 조절을 위한 분산 알고리즘이 필요하다. 본 논문에서는 기지국 사이의 데이터 전송 부하를 효과적으로 분배하는 분산 알고리즘을 제시한다. 또한, 일부 기지국에서 발행한 장애를 대응하는 방법과 새로운 기지국을 추가하는 방법을 제시한다. 모의 실험을 통해서 제안한 알고리즘의 성능을 시험하였다.

매크로셀과 마이크로셀이 중첩된 W-CDMA 무선가입자망에서 마이크로셀의 용량 산정 (Capacity esitmation of microcell in macro/microcell overlaid W-CDMA WLL system)

  • 손성찬;노재성;김수용;조성준
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2153-2164
    • /
    • 1998
  • This paper has presented the parameters for the coexistence between two systems in macro/microcell ovelaid W-CDMA WLL (wideband CDMA wireless local loop) and has calculated the capacity of forward/reverse link in microcell. To produce the capacity for analyzing system interference effects, we have shown tables and graphs with the parameters sucyh as RF channel bandwidth of WLL(W), the transmission rate of service message(R), the required signal power to noise power ratio( $E_{b/}$ $N_{0}$) for achieving accepatable error rate, te user number ( $N_{W1}$, $N_{W2}$) of the neighboring system, the signal power to interference power ratio(.GAMMA.$_{C1B}$, .GAMMA.$_{C2B}$) of the neighboring system, the normalized distance(d) between microcell and macrocell base-station, and microcell to macrocell radius ratio ( $R_{d}$). From the results, we have convinced that the capacity of microcell diminishes as increasing the user number ( $N_{W2}$) in macrocell, increasing the microcell radius, and decreasing the normalized distance(d) between microcell and macrocell base-station. Especially, we have known that when $R_{d}$=0.1, $N_{W2}$ must be below 24 at .GAMMA.$_{C2B}$ = 0 dB and below 8 at .GAMMA.$_{C2B}$ = 4 dB for the acceptable capacity raito to be over 80%. Therfore, this paper is usefult to design microcell W-CDMA WLL for accommodating more user number under the interference effects of macrocell W-CDMA WLL and is expected to be reference in power control if base-station.ation.ion.ation.ation.

  • PDF

Environmental Assessment of Smart Grid Station Project Centered on Pilot Project of Korea Electric Power Corporation Building

  • Park, Sun-Kyoung;Son, Sung-Yong;Kim, Dongwook;Kim, Buhm-Kyu
    • 한국기후변화학회지
    • /
    • 제7권3호
    • /
    • pp.217-229
    • /
    • 2016
  • Increased evidences reveal that the global climate change adversely affect on the environment. Smart grid system is one of the ways to reduce greenhouse gas emissions in the electricity generation sector. Since 2013, Korea Electric Power Corporation (KEPCO) has installed smart grid station in KEPCO office buildings. The goal of this paper is two folds. One is to quantify the reduction in greenhouse gas emissions through smart grid stations installed in KEPCO office buildings as a part of pilot project. Among components of smart grid stations, this research focused on the photovoltaic power system (PV) and energy storage system (ESS). The other is to estimate the reduction in greenhouse gas emissions when PV is applied on individual houses. Results show that greenhouse gas emissions reduce 5.8~11.3% of the emissions generated through the electricity usage after PV is applied in KEPCO office buildings. The greenhouse gas emissions reduction from ESS is not apparent. When PV of 200~500 W is installed in individual houses, annual greenhouse gas emission reduction in 2016 is expected to be approximately $2.2{\sim}5.4million\;tCO_2-eq$, equivalent to 6~15% of greenhouse gas emissions through the electricity usage in the house hold sector. The saving of annual electricity cost in the individual house through PV of 200 W and 500 W is expected to be 47~179 thous and KRW and 123~451 thousand KRW, respectively. Results analyzed in this study show the environmental effect of the smart grid station. In addition, the results can be further used as guidance in implementing similar projects.

모니터 기능을 갖는 통신기기용 전원 시스템 (Power supply system of the telecommunication equipment with monitoring function)

  • 이중기;김영태;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF

주파수제어를 위한 비열제어기구의 최적설계에 관한 연구 (A Study of Optimal Design of the Proportional Load-Frequency Controller for a Self-service Power Station)

  • 장세훈;임화영
    • 전기의세계
    • /
    • 제26권2호
    • /
    • pp.99-103
    • /
    • 1977
  • The object of this work is to study an optimal design problem of the proportional load-frequency controller for the single-control area power system. The selfservice power station is still a popular means as a power supplying source on ships or in a certain manufacturing area. The power system of this kind can be formulated as a single control-area system and it attracts a certain academic interest in controlling the system frequency under disturbances. In this paper, the single control-area system is mathematically formulated as a linear, time-invariant system in state-space under certain assumptions. The optimal proportional control law and the realization of the controller in closed loop-version is studied so that the final system designed can attain the system frequency to the nominal stationing value after the small load-disturbance. As in general cases of optimal design problems, the performance index is assumed to be quadratic in states and the control effort, and the infinite time control process is assumed in this work. The final control system realized depicts certain improvements in case study; in stability, transient responses and in steady-state frequency deviation, even though the steady state error did not attain the zero value.

  • PDF

IEEE 802.16e의 절전 클래스 I형과 II형을 위한 강화된 절전 메커니즘 (Enhanced Power Saving Mechanism for Type I and Type II Power Saving Classes in IEEE802.16e)

  • 고광섭;이경혜;문영성
    • 대한전자공학회논문지TC
    • /
    • 제49권7호
    • /
    • pp.6-11
    • /
    • 2012
  • IEEE 802.16e는 수면 모드 작동기법을 사용하여 이동 단말기(Mobile Station: MS)의 제한된 에너지를 관리한다. MS는 수면 모드의 비가용 구간에 물리적인 작동 요소의 출력을 낮출 수 있다. 이 논문은 비가용 구간를 체계적으로 증가시켜 에너지 소모율을 감소시키기 위하여, MS에 I형과 II형의 활성화된 절전 클래스(PSC)가 존재할 때 강화된 절전 메커니즘(ePSM)을 제안한다. 성능 평가 결과, ePSM은 비가용 구간뿐 아니라 에너지 소비에 있어서도 기존 방식에 비해 성능을 향상시킨 것을 확인하였다.