• 제목/요약/키워드: power station

Search Result 1,325, Processing Time 0.034 seconds

Service Coverage Analysis on Land-based DGPS Station due to Output Power Enhancement (송신출력 증강에 따른 내륙 DGPS 기준국의 서비스 영역 분석)

  • Baek, Hwa-Jong;Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.7
    • /
    • pp.1350-1357
    • /
    • 2012
  • Korean NDGPS, which consists of the ocean-based reference station of 11 site and the land-based reference station of 6 sites, are operating. The land-based reference stations provide the output power of 500W, the service shadow regions are occurred due to mountains and nation topography. In this paper, the service coverages of land-based reference stations are analyzed in the viewpoint of output power enhancements of land-based reference stations within 1KW. Also, we suggest virtual land DGPS reference stations 2 sites to resolve the service shadow regions.

Service Coverage Enhancement due to Output Power of Korean Land-based DGPS (국내 DGPS 내륙 기준국의 출력 증강에 따른 서비스 영역 분석)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.10
    • /
    • pp.2059-2064
    • /
    • 2011
  • The DGPS systems that is a GPS augmentation system were installed for ocean- and land-service. The ocean-based reference station of 11 site and the land-based reference station of 6 sites are operating for ocean- and land-service. Although the land-based reference stations provide the output power of 500W, the service shadow regions are occurred due to mountain lands and building area. In this paper, the service coverages for land-based reference stations are analyzed in conditions of output power enhancements of reference station. The service shadow areas are deduced from service coverages of land-based reference stations and ocean-based reference stations. The medium frequency-band wave propagation models are considered as DGPS wave propagation model. The service coverages are analyzed by considering the compensated ground surface-conductivity.

Two-Stage Base Station Sleeping Scheme for Green Cellular Networks

  • Yang, Juwo;Zhang, Xing;Wang, Wenbo
    • Journal of Communications and Networks
    • /
    • v.18 no.4
    • /
    • pp.600-609
    • /
    • 2016
  • In this paper, we propose a two-stage base station (BS) sleeping scheme to save energy consumption in cellular networks. The BS sleeping mode is divided into a light sleeping stage and a deep sleeping stage according to whether there is a user in the BS's coverage. In the light sleeping stage, a BS will retain its coverage and frequently switch between the on state and the doze state according to the service characteristics. While in the deep sleeping stage analysis, the BS will shut down its coverage, and neighbor BSs will patch the coverage hole. Several closed-form formulas are derived to demonstrate the power consumption in each sleeping stage and the stage switching conditions are discussed to minimize the average power consumption. The average traffic delay caused by BS sleeping and the average deep sleeping rate under a given traffic load have also been studied. In addition, it is shown that BS sleeping is not always possible because of the limited quality of service (QoS) requirements. Simulation results show that the proposed scheme can effectively reduce the average BS power consumption, at the cost of some extra traffic delay. In summary, our proposed framework provides an essential understanding of the design of future green networks that aim to take full advantage of different stages of BS sleeping to obtain the best energy efficiency.

Study on the Imported Food Safety Measures against the Fukushima Daiichi Nuclear Power Station Accident (후쿠시마 다이이치 원자력 발전소 사고 이후 각국의 수입식품 관리 조치 비교·분석에 관한 연구)

  • Shin, Seonggyun
    • The Korean Journal of Food And Nutrition
    • /
    • v.28 no.2
    • /
    • pp.202-218
    • /
    • 2015
  • Many countries have introduced new imported food safety measures, following the accident at Fukushima Daiichi Nuclear Power Station. This study was conducted to evaluate the measures contents and effects on food trades values. Eight percent of members were notified the introduced measures to the World Trade Organization. The measures' contents were banning imports, enhancing inspection and adding certification requirement. The covered regions were some prefectures, entire Japan or all affected countries. European Union introduced a measure that subjecting foods originating from 12 prefectures to import at designated ports with required certification. The measures were amended 8 times until March 2014 to apply listed foods from 15 prefectures. The trade value of fishery products and miscellaneous foods were affected. Australia introduced a measure that required additional inspection of dairy, fishery and plants products from 13 prefectures with subsequent amendments. The trade value had no effect in tested foods. Chinese Taipei introduced a temporary import ban for all foods from 6 prefectures. Trade values for fruits were affected. The United States issued an import alert for detention without examination for listed prefectures and goods without introducing new measures. Although no specific products were affected, trade values for all foods were affected.

Radiation Distribution Around Fukushima Daiichi Nuclear Power Station Decade After the Accident

  • Yukihisa Sanada;Miyuki Sasaki;Hiroshi Kurikami;Fumiya Nagao;Satoshi Mikami
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.21 no.1
    • /
    • pp.95-114
    • /
    • 2023
  • During the decades after the Fukushima Daiichi Nuclear Power Station (FDNPS) accident, ambient dose rates have markedly decreased when compared to those at the early state of the accident. Government projects have been continuously conducted by surveying the ambient dose rate and radiocesium distributions. Airborne surveys using crewed helicopters and unmanned aerial vehicles (UAVs) are the best methods for obtaining an overall picture of the distribution. However, ground-based surveys are required for accurate measurements near the population. The differences between these methods include the knowledge of the post depositional behavior of radionuclides in land use. The survey results form the basis for policy decisions such as lifting evacuation zones, decontamination, and other countermeasures. These surveys contain crucial findings regarding post-accident responses. This paper reviews the survey methods of government projects and current situation around the FDNPS. The visualization methods and databases of ambient dose rates are also reviewed to provide information to the population.

Comparison of event tree/fault tree and convolution approaches in calculating station blackout risk in a nuclear power plant

  • Man Cheol Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.141-146
    • /
    • 2024
  • Station blackout (SBO) risk is one of the most significant contributors to nuclear power plant risk. In this paper, the sequence probability formulas derived by the convolution approach are compared with those derived by the conventional event tree/fault tree (ET/FT) approach for the SBO situation in which emergency diesel generators fail to start. The comparison identifies what makes the ET/FT approach more conservative and raises the issue regarding the mission time of a turbine-driven auxiliary feedwater pump (TDP), which suggests a possible modeling improvement in the ET/FT approach. Monte Carlo simulations with up-to-date component reliability data validate the convolution approach. The sequence probability of an alternative alternating current diesel generator (AAC DG) failing to start and the TDP failing to operate owing to battery depletion contributes most to the SBO risk. The probability overestimation of the scenario in which the AAC DG fails to run and the TDP fails to operate owing to battery depletion contributes most to the SBO risk overestimation determined by the ET/FT approach. The modification of the TDP mission time renders the sequence probabilities determined by the ET/FT approach more consistent with those determined by the convolution approach.

SETTING OF HPA OUTPUT POWER IN COMS DATS CONSIDERING IMD CHARACTERISTICS

  • Park, Durk-Jong;Yang, Hyung-Mo;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.204-207
    • /
    • 2006
  • COMS will receive two different meteorological signals in S-Band from IDACS (Image Data Acquisition and Control System) in ground station before transmitting them in L-Band to user station. MODCS (Meteorological Ocean Data Communication Subsystem) in satellite released the value of required PFD (Power Flux Density) to receive two signals. Thus, DATS (Data Acquisition and Transmission Subsystem) needs to send two signals to satellite with a satisfied EIRP. The value of minimum HPA (High Power Amplifier) output power was estimated by subtracting antenna directional gain and path loss between antenna and HPA from the needed EIRP in this paper. Besides the minimum output power of HPA, the maximum output power was also calculated with considering IMD (Inter-Modulation Distortion) characteristics. IMD is always occurred in the output of HPA when LRIT and HRIT are amplified by using single HPA as COMS application. In this paper, the setting of maximum output power was determined when the IMD of modelled HPA was corresponded to the requirement of MODCS.

  • PDF

Multi-Objective Optimal Predictive Energy Management Control of Grid-Connected Residential Wind-PV-FC-Battery Powered Charging Station for Plug-in Electric Vehicle

  • El-naggar, Mohammed Fathy;Elgammal, Adel Abdelaziz Abdelghany
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.742-751
    • /
    • 2018
  • Electric vehicles (EV) are emerging as the future transportation vehicle reflecting their potential safe environmental advantages. Vehicle to Grid (V2G) system describes the hybrid system in which the EV can communicate with the utility grid and the energy flows with insignificant effect between the utility grid and the EV. The paper presents an optimal power control and energy management strategy for Plug-In Electric Vehicle (PEV) charging stations using Wind-PV-FC-Battery renewable energy sources. The energy management optimization is structured and solved using Multi-Objective Particle Swarm Optimization (MOPSO) to determine and distribute at each time step the charging power among all accessible vehicles. The Model-Based Predictive (MPC) control strategy is used to plan PEV charging energy to increase the utilization of the wind, the FC and solar energy, decrease power taken from the power grid, and fulfil the charging power requirement of all vehicles. Desired features for EV battery chargers such as the near unity power factor with negligible harmonics for the ac source, well-regulated charging current for the battery, maximum output power, high efficiency, and high reliability are fully confirmed by the proposed solution.

Theoretical and Experimental Analysis of Extremely Low Frequency Magnetic Field in the Vicinity of the Transformer Station of Overhead Power Lines

  • Ghnimi, Said;Rajhi, Adnen;Gharsallah, Ali;Bizid, Youssef
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1655-1662
    • /
    • 2018
  • This paper studies the magnetic fields between the power lines which are finite length and other ones which are infinitely long around the first tower in the proximity of the power transformers. They will be used as a source of disturbance applied to the power line. The method applied in this study was gradual; develop the theoretical formulation of the magnetic fields of these lines which are finite length and other ones which are infinitely long, examine the effects of different couplings between the different neighboring lines and the distribution transformers on behavior of magnetic fields. The method also focused on the experimental results analyzing the magnetic fields which will be used as a source applied to the auditory implants EMC. The theoretical and experimental results were compared and discussed for three power lines (90kV, 150kV and 225kV) near the power station, and it proved the effect of these substations on the simulated and measured results of the magnetic field. The maximum intensities of magnetic fields measured at the height of 1m from the ground for the circuit of three lines close to each substation were significantly lower than the ICNIRP reference levels for occupational and non occupational exposures.

A Evaluation on the Characteristics of Electrical Power System for the Station Blackout Events (원전 완전전원상실 사고에 대한 전력계통 특성평가)

  • Oh, S.H.;Zoo, O.P.;Ryu, B.H.;Chung, Y.H.;Kim, D.I.;Lim, C.H.;Kim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.140-143
    • /
    • 1993
  • Station Blackout(SBO) event means the complete loss of alternating current(AC) electrical power to the essential & nonessential switchgear buses in a nuclear power plants. Since many safety systems in nuclear power plants depend upon alternative current power, the SBO event could be an important contributor to damage of reactor core. Therefore, the SBO events have been considered as a very important safety issues in a nuclear power plants. In this paper, as evaluating the design characteristics of offsite & emergency power systems, an acceptable minimum SBO duration is calculated. And it is presented that the design method for alternative AC(AAC) sources to cope with the SBO events.

  • PDF