• 제목/요약/키워드: power space

검색결과 3,228건 처리시간 0.027초

BIPV를 위한 단축 구동 태양광 전력 발생장치 제작에 관한 연구 (A Study on the Manufacture of Single Axis Tracking Solar Power Generation System for BIPV)

  • 조재철;이진
    • 전기학회논문지
    • /
    • 제61권2호
    • /
    • pp.335-338
    • /
    • 2012
  • Recently, the energy has been used much more than ever, but there has been many problems including atmospheric pollution. So we need alternative energy resources, which are solar heat, solar light, wind power, small water power, etc. The field, which is most popular these days, is the energy source by solar light which transform electric energy using the solar cell and it is available with many researches. In this paper, we manufactured the solar power generation system over 90W using solar module which was 9.90V for Voc, 0.93 A for Isc, 8.64 V for Vmp, 0.75 A for Imp, 6.5 W for power. System was controlled by step motor with worm gear to operate optimum condition between $0^{\circ}{\sim}70^{\circ}$ angle. This system was very effective in tracking space use because it need less space than general solar module.

안전주입 실패를 동반한 제어봉구동장치 관통부 파단 사고 실험 기반 국내 안전해석코드 SPACE 예측 능력 평가 (Evaluation of SPACE Code Prediction Capability for CEDM Nozzle Break Experiment with Safety Injection Failure)

  • 남경호
    • 한국안전학회지
    • /
    • 제37권5호
    • /
    • pp.80-88
    • /
    • 2022
  • The Korean nuclear industry had developed the SPACE (Safety and Performance Analysis Code for nuclear power plants) code, which adopts a two-fluid, three-field model that is comprised of gas, continuous liquid and droplet fields and has the capability to simulate three-dimensional models. According to the revised law by the Nuclear Safety and Security Commission (NSSC) in Korea, the multiple failure accidents that must be considered for the accident management plan of a nuclear power plant was determined based on the lessons learned from the Fukushima accident. Generally, to improve the reliability of the calculation results of a safety analysis code, verification is required for the separate and integral effect experiments. Therefore, the goal of this work is to verify the calculation capability of the SPACE code for multiple failure accidents. For this purpose, an experiment was conducted to simulate a Control Element Drive Mechanism (CEDM) break with a safety injection failure using the ATLAS test facility, which is operated by Korea Atomic Energy Research Institute (KAERI). This experiment focused on the comparison between the experiment results and code calculation results to verify the performance of the SPACE code. The results of the overall system transient response using the SPACE code showed similar trends with the experimental results for parameters such as the system pressure, mass flow rate, and collapsed water level in component. In conclusion, it can be concluded that the SPACE code has sufficient capability to simulate a CEDM break with a safety injection failure accident.

저궤도 인공위성용 Regulated Peak Power Tracking(RPPT) 시스템을 위한 단순화된 직-병렬 구조 (A Simplified Series-Parallel Structure for the RPPT (Regulated Peak Power Tracking) system)

  • 양정환;배현수;이재호;조보형
    • 전력전자학회논문지
    • /
    • 제13권2호
    • /
    • pp.110-118
    • /
    • 2008
  • 기존의 저궤도 인공위성 전력계 시스템에 사용된 직렬 구조, 병렬 구조는 공전 주기 동안 두 번의 전력변환 과정을 거쳐 시스템의 효율을 감소시킨다. 직-병렬 구조는 한 번의 전력변환 과정을 거쳐 시스템의 효율을 향상시키지만 레귤레이터가 추가됨으로써 시스템의 비용과 무게, 크기를 증가시킨다. 본 논문에서는 레귤레이터의 추가 없이 시스템의 효율을 향상시키는 단순화된 직-병렬 구조를 제안한다. 인공위성이 지구를 공전하는 동안 상황에 따라 변화하는 제안한 구조의 동작을 네 가지 모드로 분류하고, 각 모드마다 제안한 시스템을 안정적인 동작을 확인하기 위하여 대신호 분석을 수행하였다. 실험을 통하여 기존의 직렬구조와 제안한 구조의 효율을 비교하였다. 제안한 구조의 안정적인 동작을 검증하기 위해 200W급 태양전지와 TMS320F2812 DSP로 제어되는 100W급 전력조절기 두 모듈을 병렬로 구성하여 실험하였다.

SED MODELING FOR CLASS 0 PROTOSTAR L1527 IRS

  • Baek, Giseon;Lee, Jeong-Eun;Lee, Seokho
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.42.1-42.1
    • /
    • 2015
  • We model the Spectral Energy Distribution (SED) of Class 0 protostar L1527 IRS using a radiative transfer code RADMC-3D. In addition to the photometry data from literatures, we include the Herschel/PACS data which well covers the far-infrared SED peak of L1527 IRS, providing precise constraints to the density structure and other physical properties of its circumstellar envelope. Previously, Tobin et al. (2013) presented a dust continuum modeling results using a rotating and infalling envelope (Terebey and Shu, & Cassen 1984 ; TSC envelope), which originally describes a power-law density profile (${\rho}{\propto}r-{\alpha}$) with the power-law index (${\alpha}$) of 1.5. However, we find that Herschel/PACS data are better fitted with a shallower power-law density profile. This smaller power-law might be attributed to a inner envelope. Thus, we fit the SED of L1527 IRS with a Bonnor-Ebert sphere, which is a combination of the inner flat-topped and the outer power-law (${\alpha}=2$) density profiles. This Bonnor-Ebert sphere is often used to explain the density profile of prestellar cores, which is considered the earliest stages of star formation. The well-fitted SED with a Bonnor-Ebert sphere suggests that L1527 IRS might have collapsed from a Bonnor-Ebert sphere rather than a singular isothermal sphere.

  • PDF

The Optimal Controller Design of Buck-Boost Converter by using Adaptive Tabu Search Algorithm Based on State-Space Averaging Model

  • Pakdeeto, Jakkrit;Chanpittayagit, Rangsan;Areerak, Kongpan;Areerak, Kongpol
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권3호
    • /
    • pp.1146-1155
    • /
    • 2017
  • Normally, the artificial intelligence algorithms are widely applied to the optimal controller design. Then, it is expected that the best output performance is achieved. Unfortunately, when resulting controller parameters are implemented by using the practical devices, the output performance cannot be the best as expected. Therefore, the paper presents the optimal controller design using the combination between the state-space averaging model and the adaptive Tabu search algorithm with the new criteria as two penalty conditions to handle the mentioned problem. The buck-boost converter regulated by the cascade PI controllers is used as the example power system. The results show that the output performance is better than those from the conventional design method for both input and load variations. Moreover, it is confirmed that the reported controllers can be implemented using the realistic devices without the limitation and the stable operation is also guaranteed. The results are also validated by the simulation using the topology model of MATLAB and also experimentally verified by the testing rig.

Development of dynamic motion models of SPACE code for ocean nuclear reactor analysis

  • Kim, Byoung Jae;Lee, Seung Wook
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.888-895
    • /
    • 2022
  • Lately, ocean nuclear power plants have attracted attention as one of diverse uses of nuclear power plants. Because ocean nuclear power plants are movable or transportable, it is necessary to analyze the thermal hydraulics in a moving frame of reference, and computer codes have been developed to predict thermal hydraulics in large moving systems. The purpose of this study is to incorporate a three dimensional dynamic motion model into the SPACE code (Safety and Performance Analysis CodE) so that the code is able to analyze thermal hydraulics in an ocean nuclear power plant. A rotation system that describes three-dimensional rotations about an arbitrary axis was implemented, and modifications were made to the one-dimensional momentum equations to reflect the rectilinear and rotational acceleration effects. To demonstrate the code's ability to solve a problem utilizing a rotational frame of reference, code calculations were conducted on various conceptual problems in the two-dimensional and three-dimensional pipeline loops. In particular, the code results for the three-dimensional pipeline loop with a tilted rotation axis agreed well with the multi-dimensional CFD results.

Seismic evaluation of different types of electrical cabinets in nuclear power plants considering coupling effects: Experimental and numerical study

  • Md Kamrul Hasan Ikbal;Dong Van Nguyen;Seokchul Kim;Dookie Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3472-3484
    • /
    • 2023
  • The objective of this research is to assess the seismic performance of different types of electrical cabinets in nuclear power plants. The cabinets under investigation are: (a) Case 1: a short single cabinet; (b) Case 2: a tall single cabinet; (c) Case 3: separated cabinets; and (d) Case 4: a combined cabinet with coupling effects. To accurately capture the real behavior of the cabinet, three-dimensional finite element models are developed using ANSYS with connection non-linearity. Frequency domain decomposition (FDD) is used to determine the dynamic properties of the cabinets from shaking table testing data, and these results are utilized to validate the numerical model. The close match between the experimental and numerical results obtained from the modal analysis demonstrates the accuracy of the numerical model. Subsequently, transient structural analysis is performed on the validated models to explore seismic performance. The results show that the acceleration response of the combined cabinet is lower than the single cabinet and the separated cabinet. This observation suggests that top anchors used to combine two different types of cabinets play a crucial role in assessing the efficiency and seismic resistance of electrical cabinets in a nuclear power plant.

GaInP/GaAs/Ge 3중 접합 태양전지 배열기의 정지궤도에서 전력 성능 평가 (GaInP/GaAs/Ge Triple Junction Solar Array Power Performance Evaluation on Geostationary Orbit)

  • 구자춘;박희성;이나영;천이진;차한주;문건우;나성웅
    • 한국항공우주학회지
    • /
    • 제42권12호
    • /
    • pp.1057-1064
    • /
    • 2014
  • 정지궤도위성은 다수의 탑재체를 하나의 위성체 플랫폼에 탑재하고 2010년 6월 26일에 발사되었다. 태양기간 동안 인공위성에서 요구되는 전력은 태양전지 배열기 윙에서 생성된다. 태양전지는 Spectrolab사의 적층법을 사용한 RWE Space사의 Gaget 2로 명명되는 GaInP/GaAs/Ge 3중 접합 셀이다. 본 논문은 정지궤도 비행 데이터에 대한 경향을 분석한 결과를 바탕으로 설계수명 말기에서 태양전지 배열기의 전력 성능을 평가하였다. 설계수명 말기에서 예측한 태양전지 배열기의 전력 성능은 태양전지 배열기 제작사가 제공한 전력 성능과 비교하였다. 경향분석 결과를 통해 태양전지 셀은 현저한 성능감소 없이 정상적으로 동작되고 있다.