시로코 홴 성능 및 공력 소음 예측에 관한 연구 (Measurement and Prediction of Aerodynamic Noise from Sirocco Fans)

  • 김경호;박계찬;이승배
    • 한국유체기계학회 논문집
    • /
    • 제2권4호
    • /
    • pp.57-64
    • /
    • 1999
  • The prediction method of the performance and aerodynamic noise from a sirocco fan was developed and compared with measured data. To predict the performance of the sirocco fan, the well-known slip coefficients and various loss models were tested and applied to forward curved sirocco impellers. Using loss models proposed for both impeller and casing, the predicted performance characteristics were in good agreement with measured ones by an ANSI test plenum. Various scaling models for aerodynamic noise from the sirocco fan were evaluated and tested against measured power levels in terms of flow coefficient. It was shown that the turbulent broadband sound power from the sirocco fan can be modeled successfully by trailing edge noise.

  • PDF

적응 부밴드 필터링을 이용한 전력계통 시변 주파수와 고조파 검출 및 추적 (Detection and Tracking of Time Varying Power System Frequencies and Harmonics using Subband Adaptive Filtering)

  • 손상욱;최훈;배현덕
    • 전기학회논문지
    • /
    • 제58권4호
    • /
    • pp.679-687
    • /
    • 2009
  • In this paper, a subband filtering and adaptive prediction technique for analyzing harmonics in power systems is presented. In this method, the filter banks are designed to decompose odd and even order harmonics separately. The adaptive prediction has been employed reduce the transient and white noise effect in time varying harmonics detecting and tracking. The frequencies and amplitudes of the decomposed harmonics are estimated by recursive algorithm. To demonstrate the performances of the developed technique, computer simulations to the signal with the time-varying frequency and THD are carried out.

Implementation of Robust Prediction Observer Controller for DC-DC Converter

  • Shenbagalakshmi, R.;Raja, T. Sree Renga
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1389-1399
    • /
    • 2013
  • A discrete controller is designed for low power dc-dc switched mode power supplies. The approach is based on time domain and the control loop continuously and concurrently tunes the compensator parameters to meet the converter specifications. A digital state feedback control combined with the load estimator provides a complete compensation, which further improves the dynamic performance of the closed loop system. Simulation of digitally controlled Buck converter is performed with MATLAB/Simulink. Experimental results are given to demonstrate the effectiveness of the controller using LabVIEW with a data acquisition card (model DAQ Pad - 6009).

Markov Chain을 이용한 핸드폰 메뉴 선택 예측 (Prediction of Mobile Phone Menu Selection with Markov Chains)

  • 이석원;명노해
    • 대한산업공학회지
    • /
    • 제33권4호
    • /
    • pp.402-409
    • /
    • 2007
  • Markov Chains has proven to be effective in predicting human behaviors in the areas of web site assess, multimedia educational system, and driving environment. In order to extend an application area of predicting human behaviors using Markov Chains, this study was conducted to investigate whether Markov Chains could be used to predict human behavior in selecting mobile phone menu item. Compared to the aforementioned application areas, this study has different aspects in using Markov Chains : m-order 1-step Markov Model and the concept of Power Law of Learning. The results showed that human behaviors in predicting mobile phone menu selection were well fitted into with m-order 1-step Markov Model and Power Law of Learning in allocating history path vector weights. In other words, prediction of mobile phone menu selection with Markov Chains was capable of user's actual menu selection.

유압식 착암기 치즐의 타격 변형량 해석에 관한 연구 (A Study On the Analysis Of Impact Strain for Hydraulic Breaker Chisel)

  • 박종원;이기욱;김형의
    • 유공압시스템학회논문집
    • /
    • 제4권4호
    • /
    • pp.21-27
    • /
    • 2007
  • A hydraulic breaker for construction machinery generally used for the destroying and disassembling of buildings, crashing road pavement, breaking rocks at quarry and so on. So the measurement of the impact energy of a hydraulic breaker is very important thing to prove its capability to manufacturers and customers. Therefore the prediction of impact energy in design process is very helpful to the most of breaker manufacturers. In this study, we carried on modeling and simulation of a hydraulic breaker to predict impact energy via commercial CAE software. The modeling and simulation of a hydraulic breaker was achieved with two parts. One is a hydraulic circuit analysis part via AMESim and the other is impact strain analysis part via ANSYS.

  • PDF

초고압 가공 송전선로의 라디오 잡음 예측계산식 개발 (I) (Formulas for Predicting Radio Noise from Overhead HVAC Transmission Lines)

  • 양광호;주문노;명성호;신구용;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1088-1090
    • /
    • 1999
  • The radio noise produced by corona discharge in high voltage transmission tines is one of the most important line design considerations. Therefore it is necessary to pre-evaluate radio noise for transmission line designers using Prediction formulas or field test results. In this Paper, more accurate and useful formulas for Predicting radio noise during fair and foul weathers in AC transmission lines were proposed through comparison with the existing formulas. Also it was verified by comparing with the long-term measured data from operating lines that the Proposed formulas are very accurate. The Proposed prediction formulas are developed by the applications of nonlinear least square optimization method to radio noise database collected from lines throughout the world.

  • PDF

대형 컨테이너운반선의 공조 소음 해석사례 (Noise Analysis of Large Container Carrier Vessel on HVAC Noise)

  • 김문수;조대승;김병희;권종현
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2006년도 특별논문집
    • /
    • pp.65-70
    • /
    • 2006
  • In this paper, we introduce prediction program of HVAC system, HJNOVAC Version 2.0. The developed program adopts both the authentic empirical method suggested by NEBB and acoustic power balancing method. The program provides intuitive pre- and post- processor using modern GUI function to help efficient modeling and evaluation of cabin and HVAC component noises. To verify the accuracy and convenience of the program, we carry out noise prediction of HVAC system for 8,100 TEU Container Carrier and measure the noise levels of cabins during sea trial.

  • PDF

소형 모형선을 이용한 실선마력추정에 대한 연구 (A Fundamental Study on the Power Prediction Method of Ship by using the Experiment of Small Model)

  • 하윤진;이영길
    • 대한조선학회논문집
    • /
    • 제51권3호
    • /
    • pp.231-238
    • /
    • 2014
  • In this study, the self-propulsion tests are performed in INHA towing tank. And the effective wake characteristics of the KVLCC2 and the KCS models are compared by the experimental results. The form factor is independent of Reynolds number. To estimate the hydrodynamic performance of a full scale ship, the form factor is determined to consider attendant on Reynolds number. In this research, the power predictions are carried out considering the form factor difference of model and full scale ship. The results of this research could be used as one of the fundamental data to the powering performance prediction.

광음향기법을 이용한 한국형 고속전철의 실내소음 예측 (Interior noise prediction of the high speed train using ray method)

  • 김관주;박진규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.157-164
    • /
    • 2000
  • This study is about predicting the interior pressure level of the korean high speed train using ray acoustic method. The motor car and the motor and passenger cabin are investigated under the environment of passing open countryside and inside tunnel of 350 km/hr. Calculated sound levels are compared with the proposed sound levels and suggestions about the transmission Joss values of isolating panels inside motor car and the guide lines of allowed sound power limit of motor equipments are provided. Results of TPI car show calculated interior sound level is below the proposed values for both cases of open countryside running and inside tunnel. Since ray acoustic method calculated only air borne noise component, real sound level of the motor car may be higher than prediction. Passenger cabins of TMI, TM5 show higher sound level than the proposed values, so window method was carried out to find the contribution of each panel components and point out the remedy of transmission path. Reduction of sound power of motor equipments should be condisered at the same time.

  • PDF

145kV 40kA 3상 GIS 모선의 온도상승 예측 (Temperature Rise Prediction of 145kV 40kA Three-phase GIS Bus Bar)

  • 김중경;이지연;정상용;한성진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.842-843
    • /
    • 2008
  • Many works on the temperature prediction of power apparatus have usually done by coupled magneto-thermal analysis. However, this method can not consider the internal gas or oil flow in the power apparatus. This paper proposes a new coupled magneto-thermal-flow analysis considering Navier-Stokes equations. The convection heat transfer coefficient is calculated analytically and is applied to the boundary condition to the proposed method. Temperature distribution of 145kV 40kA three-phase GIS bus bar model is obtained by coupled magneto-thermal-flow analysis and shows good agreement with the experimental data.

  • PDF