• Title/Summary/Keyword: power meter

Search Result 532, Processing Time 0.029 seconds

A study on the security analysis and evaluation of the web based metering/billing system for the value storage electricity meter (전력전자상거래(VSEM)를 위한 웹기반 미터링/과금 시스템의 보안성 분석 및 평가에 관한 연구)

  • Kang Hwan-Il;Song Young-Ki;Kang Hwan-Soo;Jo Jin-Hyung;Jang Woo-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.462-464
    • /
    • 2006
  • 본 연구는 제4세대 미터링(Metering) 기술을 이용한 전력전자상거래 즉 VSEM(Value Storage Electricity Meter)을 위한 웹기반 미터링 시스템의 보안성 분석 및 평가에 관한 연구이다. 특히 수요자 측면에서 스마트카드(지불결제)를 이용한 본인 확인(SIM카드), 키 값 확인, VSEM서버에서의 각 수요자와 공급자 데이터 사이의 무결성 확인(Integrity)과 부인 방지(Non-repudiation)를 위한 기존 시스템의 보안 문제를 분석하고 이를 해결할 수 있는 보안 모델을 제안한다.

  • PDF

Device Authentication Protocol for Smart Grid Systems Using Homomorphic Hash

  • Kim, Young-Sam;Heo, Joon
    • Journal of Communications and Networks
    • /
    • v.14 no.6
    • /
    • pp.606-613
    • /
    • 2012
  • In a smart grid environment, data for the usage and control of power are transmitted over an Internet protocol (IP)-based network. This data contains very sensitive information about the user or energy service provider (ESP); hence, measures must be taken to prevent data manipulation. Mutual authentication between devices, which can prevent impersonation attacks by verifying the counterpart's identity, is a necessary process for secure communication. However, it is difficult to apply existing signature-based authentication in a smart grid system because smart meters, a component of such systems, are resource-constrained devices. In this paper, we consider a smart meter and propose an efficient mutual authentication protocol. The proposed protocol uses a matrix-based homomorphic hash that can decrease the amount of computations in a smart meter. To prove this, we analyze the protocol's security and performance.

A study on the application of a method of an intensity of illumination measurement for light flickering (광플리커링에 대한 조도측정법의 적용에 관한 연구)

  • Choi Young-Ha;Lee Kang-Won;Ohn Jung-ghun;Shim Jae-Bock;Kwon Ki-Jin;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1402-1406
    • /
    • 2004
  • As a method of confirming light flickering, we tried to confirm the flicker index measured by Flickermeter and the application possibility by using digital intensity of illumination meter. Also, after simulating the quality deterioration of electric power and generating a various voltage change, we studied on the function between the flicker index measured by Flickermeter and the flicker index for the intensity of illumination by using digital intensity of illumination meter.

  • PDF

Design and Fabrication of a PD Detector for Power Cable Diagnosis (전력케이블 진단을 위한 부분방전 검출장치의 설계 및 제작)

  • Song Jae-Yong;Seo Hwang-Dong;Kil Gyung-Suk;Han Moon-Soeb;Jang Dong-Uk
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.777-782
    • /
    • 2005
  • In this paper, we designed and fabricated a partial discharge (PD) detector to diagnose the soundness of CNCV cables by analyzing PD pulses and to predict discharge locations. The PD detector is consisted of a coupling network with a discharge free capacitor and a detection impedance, a voltage follower and a low noise amplifier. Lower cut-off frequency of the detector is adjusted at 175kHz to block AC voltage and to pass discharge pulse only. The discharge location could be obtained by the time of arrival method using travelling wave propagation theory. In a laboratory test on an eighty meter CV cable, we could position the discharge location within a two meter error.

  • PDF

R&D Trends and Prospects of Automatic Meter Reading System (원격검침 시스템의 기술개발 동향 및 발전 전망)

  • Lee, Jeong-Keun;Lee, Dal-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.150-154
    • /
    • 2008
  • 통신기술과 컴퓨터기술의 발전으로 새로운 전기통신 서비스가 개발 보급되고, 그 예로 도난, 화재, 가스 유출 등 가정 안에서 일어나는 각종 위급상황을 해당관서에 자동으로 알려주는 원격 안전관리시스템의 중요성과 인력 검침에 따른 노동력 확보문제나 효율적이고 경제적인 검침에 따른 운용방안이 요구되는 시점에서 원격검침 시스템(AMRS)의 필요성이 더욱 대두되고 있다. 본 논문에서는 각각의 원격 검침 시스템의 사용된 통신 방식을 비교하고 원격 검침시스템의 국내 외 기술 개발 동향 및 앞으로의 발전방향을 모색하였다. 이에 고유가시대의 검침비용을 절감하고 고객 서비스 향상 방안에 도움이 되고자 한다.

  • PDF

A Study on the Requirements Analysis and Design for System Development of Remote Firmware Upgrade Management System Based-on AMI (AMI 기반 원격 펌웨어업그레이드 시스템 개발을 위한 요구분석 및 설계에 관한 연구)

  • Jung, Nam-Joon;Yang, Il-Kwon;Choi, Seong-Hwan;Jin, Young-Taek
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.1
    • /
    • pp.155-161
    • /
    • 2012
  • The firmware upgrade, which is remotely performed, is an essential function in smart metering or AMI (Advanced Metering Infrastructure). In other words, the AMI software and firmware can be switched for maintaining and improvement without replacement of H/W devices in AMI environment. Also, if number and type of devices are increase, the demand of remote update service will be increased. Through the firmware upgrade service remotely, the electric power corporation may be able to benefit various fields. For example, there are to adapt more easily in many environments, real-time service and to cut maintenance costs. In this paper, we proposed to design an international level FUMS(Firmware Upgrade Management System) which includes requirement function, architecture and protocol related with DCU, Smart Meter.

An Efficient Channel Selection and Power Allocation Scheme for TVWS based on Interference Analysis in Smart Metering Infrastructure

  • Huynh, Chuyen Khoa;Lee, Won Cheol
    • Journal of Communications and Networks
    • /
    • v.18 no.1
    • /
    • pp.50-64
    • /
    • 2016
  • Nowadays, smart meter (SM) technology is widely effectively used. In addition, power allocation (PA) and channel selection (CS) are considered problems with many proposed approaches. In this paper, we will suggest a specific scenario for an SM configuration system and show how to solve the optimization problem for transmission between SMs and the data concentrator unit (DCU), the center that collects the data from several SMs, via simulation. An efficient CS with PA scheme is proposed in the TV white space system, which uses the TV band spectrum. On the basic of the optimal configuration requirements, SMs can have a transmission schedule and channel selection to obtain the optimal efficiency of using spectrum resources when transmitting data to the DCU. The optimal goals discussed in this paper are the maximum capacity or maximum channel efficiency and the maximum allowable power of the SMs used to satisfy the quality of service without harm to another wireless system. In addition, minimization of the interference to the digital television system and other SMs is also important and needs to be considered when the solving coexistence scenario. Further, we propose a process that performs an interference analysis scheme by using the spectrum engineering advanced Monte Carlo analysis tool (SEAMCAT), which is an integrated software tool based on a Monte-Carlo simulation method. Briefly, the process is as follows: The optimization process implemented by genetic evolution optimization engines, i.e., a genetic algorithm, will calculate the best configuration for the SM system on the basis of the interference limitation for each SM by SEAMCAT in a specific configuration, which reaches the solution with the best defined optimal goal satisfaction.

Review on Data Acquisition of Renewable Power Generators (신재생발전기의 데이터 취득방안에 대한 고찰)

  • Lee, Bong-Kil;Kim, Wan-Hong;Choi, Joon-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.1-20
    • /
    • 2020
  • In accordance with the Government's policy, renewable power generation is expanding very largely. This leads to increasing uncertainty in the power market and power system owing to the intermittent and fluctuating output characteristics of renewable power generators. Data on the acquisition of renewable power generators can be largely classified according to the operation of the power market and power system. Data on the settlement for the payment for the power amount are acquired in the power market, and real-time data for monitoring the status and output of the generators are acquired in the power system. However, renewable power generators operating in the power market have different acquisition cycles depending on the method of communication of the power meter. They acquire data only for settlement purposes and have no real-time data, which requires improvement. In this paper, the acquisition status is reviewed by classifying the data of renewable power generators into settlement and real-time data. In addition, measures and acquisition criteria for real-time data of renewable power generators for improving the acquisition method are proposed.

Development of Demand Controller Using Power line

  • Kim Ho;Kwak Dong-Hyun;Lee Jeong-Bok;Seok Won-Youp;Han Seong-Ryong;Jeon Hee-Jong
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.552-555
    • /
    • 2001
  • In this paper, an intelligent demand control system was introduced. This system are composed of demand controller, RTU, power line modem and HMI program. The proposed demand controller was capable of synchronizing with watt-hour meter recommended by KEPCO(Korea Electrical Power Corporation). To control remote loads, network function using powerline communication is implemented in RTU with HMI program and novices are able to operate system easily. Additionally using the power line, the cost and time of installation can b saved. The system performance was proved with a several experiments.

  • PDF

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..