• Title/Summary/Keyword: power line data transmission

Search Result 241, Processing Time 0.025 seconds

Analyzing the Architecture of EPON Network for CATV Overlay (CATV Overlay를 위한 EPON 망 구조에 대한 분석)

  • 이상연;김용태;이재정;이형섭
    • Proceedings of the IEEK Conference
    • /
    • 2003.11c
    • /
    • pp.117-120
    • /
    • 2003
  • PON (Passive Optical Network) is an emerging local subscriber access architecture that provides more bandwidth and services to subscriber than DSL (Digital Subscriber Line and HFC (Hybrid-Fiber Coaxial) network. A PON is a point-to-multipoint optical network with no active elements in the signals' path from source to destination. Advantages of using PON for a subscriber access network include large coverage area, reduced fiber deployment, multicast and broadcast capabilities, reduced cost of maintenance (due to devices being passive), and ease of upgrades to higher bit rate or additional wavelengths. PON uses WDM (Wavelength Division Multiplexing) technique that transmits the downstream and upstream data at each different wavelength. For transmitting the CATV (Community Antenna television) service through PON network, we give out additional wavelength. This study shows the available TPS (Triple play service) architecture using CATV overlay EPON (Ethernet PON) architecture and analyzes the effects of EPON-based CATV transmission by measuring the power loss fur each wavelength and the power range of the available analog wavelength and RF.

  • PDF

Development of a Reclosing Scheme for Reduction of Turbine Generator Shaft Torsional Torques: A Decision Method to Achieve Optimal Reactor Capacity

  • Oh, Yun-Sik;Seo, Hun-Chul;Yang, Jeong-Jae;Kim, Chul-Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1145-1153
    • /
    • 2014
  • It is well known that line switching operations like reclosing are able to cause transient power oscillations which can stress or damage turbine generators. This paper presents a reclosing scheme to reduce the shaft torsional torques of turbine generators by inserting an additional reactor. A novel method to determine optimal reactor capacity to minimize the torsional torque generated in a turbine generator is also proposed. In this paper, the turbine generator shaft is represented by a multi-mass model to measure torsional torques generated in the shaft between the turbine and the generator. Transmission systems based on actual data from Korea are modeled to verify the proposed scheme using ElectroMagnetic Transient Program (EMTP) software. The simulation results clearly show the effectiveness of the proposed scheme and torsional torque can be minimized by applying the proposed scheme.

Quantifying Optical Link Loss of Fiber-to-the-Home Infrastructure

  • Karan Bahadur Bhandari;Bhanu Shrestha;Surendra Shrestha
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.48-58
    • /
    • 2024
  • Fiber to the Home (FTTH) technology is among the most advanced broadband services, delivering voice, data, and television through a single optical fiber directly to customer premises, ensuring high-speed and reliable connectivity. The study conducted on Nepal Telecom's FTTH networks involved direct measurements from the optical line terminal to the fiber access point and optical network unit, providing detailed insights into network performance. Using the OptiSystem software, the analysis revealed a link loss of 24.99 dB, a Q-factor of 12.98, and a minimum Bit Error Rate (BER) of 7.31E-39, all within standard limits, which underscores the robustness of the network. The study also identified that the highest contributors to signal loss were connector loss, fiber attenuation, and fusion splices, emphasizing the importance of minimizing these factors to maintain optimal network performance. Overall, these findings highlight the critical aspects of FTTH network design and maintenance, ensuring that service providers can deliver high-quality broadband services to customers.

Iterative Coding for High Speed Power Line Communication Systems (고속 전력선 통신 시스템을 위한 반복 부호화 기법)

  • Kim, Yo-Cheol;Cho, Bong-Youl;Lee, Jae-Jo;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.11 no.5
    • /
    • pp.185-192
    • /
    • 2011
  • In this paper, we simulate and analyze performance of iterative coding scheme, double binary turbo code, for high speed power line communication (PLC) systems. PLC system has hostile environment for high speed data transmission, so error correction method is necessary to compensate effects of PLC channel. We employ the PLC model proposed by M. Zimmerman and Middleton Class A interference model, and system performance is evaluated in terms of bit error rate (BER). From the simulation results, we confirm double binary turbo code provides considerable coding gains to PLC system and BER performance is significantly improved as the number of iteration increase. It is also confirmed that BER performance increases as code rate is lager, while it decreases as the code rate is smaller.

A study on the receiving rate of the data of the hybrid communication system using data transfer methods for controller system of navigational aids (데이터 전송방식에 따른 항로표지 관리용 하이브리드 통신 시스템의 수신율 분석에 관한 연구)

  • Jeon, Joong Sung
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.78-85
    • /
    • 2014
  • The Mu-communication board supported by hybrid communication is designed with Cortex M3, which is a low power energy consumption 32-bit microcontroller. The Cortex M3 microcontroller has UART(Universal asynchronous receiver/transmitter) ports which can set appropriately using the command line interpreter (CLI) program with each port. URAT ports are used for hybrid communication modems, GPS modules, etc. When the socket type was compared with the short message service type, the socket type was proven to be better. By improving the receiving performance in the control and management system of the AtoN, data loss was minimized. During the testing of the socket and SMS, data was collected from each buoy for 12 hours every 1 minute and the receiving rate of the data was found to be more than 98.58 % and 99.42 % respectively.

Bias Compensation Algorithm of Acceleration Sensor on Galloping Measurement System

  • Kim, Hwan-Seong;Byung, Gi-Sig;So, Sang-Gyun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.127.6-127
    • /
    • 2001
  • In this paper, we deal with two bias compensation algorithms of acceleration sensor for measuring the galloping on power transmission line. Firstly, the block diagram of galloping measurement system is given and a galloping model is presented. Secondly, two compensation algorithms, a simple compensation and a period compensation, are proposed. A simple compensation algorithm use the drafts of velocity and distance at fixed periods, so it is useful for constant bias case. Next, a period compensation algorithm can compensate a periodic bias. This algorithm use the previous measured data and compensated data for constant period, where the period is obtained by FFT method. Lastly, the effectiveness of proposed algorithms is verified by comparing between two algorithms in simulation, and its characteristics and the bias error bound are shown, respectively.

  • PDF

A Study on the Development of the Digital Distance Relay Simulator for Education using GUI (GUI를 이용한 교육용 디지털 거리계전기 시뮬레이터 개발에 관한 연구)

  • Kim Dong-Su;Kim Chul-Hwan;Lee Ki-Teak;Park Nam-Ok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.8
    • /
    • pp.388-395
    • /
    • 2005
  • It has always been of great importance in the electrical power system to educate an algorithm on the digital relaying, but it is difficult to educate an algorithm of a digital distance relay on power system because of exclusiveness of the relaying algorithm on power system. Therefore, we need a digital distance relay simulator, which can simulate the algorithm of the digital relaying on transmission line. In this Paper, we extract fundamental components using digital signal processing from data which are a variety of the simulated faults by EMTP. Then this simulator represents instantaneous values, ms values and symmetrical components that are calculated by fundamental components of voltages and currents. The Simulator also represents the zones of a digital distance relay and the locus of an impedance using GUI. Consequently, the developed simulator is particularly useful for understanding of the fundamental concepts of a distance relaying algorithm from a power system engineer points of view.

The Leakage Current Analysis of ZnO Arrester Using Leakage Current Dete (피뢰기 누설전류 분석장치를 이용한 ZnO 피뢰기의 누설전류 변화 분석)

  • Kim, Young-Chun;Moon, Sun-Ho;Oh, Jung-Hwan;Kim, Jae-Chul;Lee, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1082-1084
    • /
    • 1998
  • In this paper, we developed a diagnosis device for ZnO arrester to detect on-line leakage current and acquire data from the power distribution system. The arrester is important power equipment used in power transmission and distribution systems to protect the generator and the main transformer from surge and overvoltage. First of all we developed a diagnosis device for ZnO arrester leakage current. And then we detect the total leakage current by the developed device without disconnecting the arrester ground wire and analysis the 3rd order harmonic by Fast Fourier Transform(FFT) to diagnose the ZnO arrester deterioration. With measuring the total current and the resistive current of power distribution system in operation, we analysis the trend of resistive current component in the total leakage current. We expect the result will be promote the method to protect electrical utility and customer from accident.

  • PDF

Development of Communication Joint Tools for Implementing a Legacy-line Communication System in a Train (열차 내 무배선통신시스템 구축을 위한 통신연결장치 개발)

  • Kim, Hyun Sik;Park, Soo Hoon;Kang, Seog Geun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.4
    • /
    • pp.877-887
    • /
    • 2015
  • In this paper, a design of communication joint tools to implement a legacy-line communication (LLC) system, which exploits various conductive lines in a train, is presented. We develop two kinds of joint tools; one is a conductive joint tool (CJT) that is connected directly to the conventional lines and the other is the inductive joint tool (IJT) which connects the conventional lines indirectly using electromagnetic induction. As a result, the practical experiment of data communication confirms that an LLC system with the developed joint tools has a transmission rate more than 20 Mbps in the distance of 200 m away. In addition, an environmental durability test shows that the joint tools operate stably in an extreme environmenal variation. It is, therefore, considered that the developed joint tools are very useful to implement a communication network in the train working currently.

An Achievement of High-rate Digital Subscriber Lines(HDSL) Interface Function into the ATM Switching System and its Service Implementation (ATM에HDSL 정합 기능 및 서비스 구현)

  • Yang, Choong-Reol;Chang, J.D.;Kim, J.T.;Kang, S.Y.;Kim, W.W.
    • The Transactions of the Korea Information Processing Society
    • /
    • v.4 no.9
    • /
    • pp.2378-2390
    • /
    • 1997
  • We, in this paper, have implemented E1 HDSL(high-bit-rate digital subscriber line) function over an ATM switching system. The maximum loop lengths for subscriber service and cell loss rates to meet the bit error rate of $10^{-7}$ at transmission of 2B1Q HDSL data of E1 rate over existing telephone copper wires in the presense of the significant impairments such as crosstalk, impulse noise, power line noise and longitudinal over the CSAs environment consisting of 26 gauge and 24 gauge unloaded copper telephone lines has assessed. We have confirmed the typical media services function such as video on demand(VOD) service for MPEG-1, image conference service and high-speed Internet access service over ATM switching system.

  • PDF