• Title/Summary/Keyword: power line data transmission

Search Result 241, Processing Time 0.021 seconds

Development of a Lighting Control Switch Using Power Line Communication Technology (전력선 통신기술을 이용한 조명제어 스위치의 개발)

  • Song Jae-yong;Moon Seung-bo;kil Gyung-suk;Lee Gyung-soo;Kim Chang-yul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.4
    • /
    • pp.792-797
    • /
    • 2005
  • Lighting control switches based on the power line communication technology are developed and extended to incorporate dimming control to provide energy saving and appropriate illumination. The developed switch uses a general purpose microprocessor and associated electronics. Both the power line communication and the dimming function are implemented in one microprocessor, and it enables the low price commercialization. The frequency of the carrier was set at 250kHz considering the transmission data length and signal attenuation in power lines. Tests on prototypes in an low-voltage power lines have shown that the switches have a robust operation characteristics with the length of power lines and the variation of load capacities.

Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line (고압 배전선로 전력선 통신 신호결합장치 개발)

  • Lee Jae-Jo;Park Young-Jin;Oh Hui-Myoung;Kim Kwan-Ho;Lee Dae-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

A Method development of Power Line Location and 3D Modeling using LiDAR Data (라이다 데이터를 이용한 송전선로 위치 추출 및 3차원 모델링 기법 개발)

  • Kim, Eun-Young;Kim, Seong-Yong;Lee, Kang-Won
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.389-393
    • /
    • 2007
  • There has been many researches using LiDAR(Light Detection And Ranging) data. There has been many other researches through out the world using the 3 dimensional spatial data in various fields. In this research, Using lidar data and digital images, we have extracted the position of the power-transmission line and created 3 dimensional models. The presented method is more efficient than field surveying and it can also be used lot monitoring change in the environment

  • PDF

A Study on the Characteristics of the Synchroneous Data Transmission by the Phase Band Limit of AC Power Wave to Avoid the Periodic Noises in the Data Communication System of Distribution Line Carrier Method (배전선 반송 데이타통신에서의 전원동기 위상대역한정 전송에 의한 주기적 노이즈신호 회피특성에 관한 연구)

  • 최순만;노창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.3
    • /
    • pp.78-84
    • /
    • 1994
  • The location of periodic noises in phase of AC power wave reveals to be specific according to the noise kinds which can be generally classified into modulation and baseband types in DLC. The former noise type has constant noise phase which is originated from switching mode power supplies and the latter normally caused from thyristor circuit of low switching frequency is compared to be more dispersive than the other.

  • PDF

Development of an Equipment for Monitoring Current and Voltage on a Power Transmission Line

  • K. Kuwanami;E.Jishiuama;T Matsuda;I.Oota;H.Kuribayashi;N. Ueda;Ha, S.yata
    • Proceedings of the IEEK Conference
    • /
    • 2000.07a
    • /
    • pp.233-236
    • /
    • 2000
  • A portable equipment that measures a current and voltage waveform of power transmission lines is pro-posed. In the equipment, the current and voltage, respectively, are detected by a loop coil and a capacitor clamped around the power lines. The detected data is transmitted by an FM wave to the receiver on the ground station. Since the receiver is isolated from the power lines, we do not require high potential insulators for the measurement of current and voltage. The proposed equipment is therefore, small-sized, light, and low in the cost of production. Experimental results presented here show that the equipment can monitor the current flowing in single wire over a ground plane and the potential of the wire.

  • PDF

Two-Terminal Numerical Algorithm for Single-Phase Arcing Fault Detection and Fault Location Estimation Based on the Spectral Information

  • Kim, Hyun-Houng;Lee, Chan-Joo;Park, Jong-Bae;Shin, Joong-Rin;Jeong, Sang-Yun
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.460-467
    • /
    • 2008
  • This paper presents a new numerical algorithm for the fault location estimation and arcing fault detection when a single-phase arcing ground fault occurs on a transmission line. The proposed algorithm derived in the spectrum domain is based on the synchronized voltage and current samples measured from the PMUs(Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm uses DFT(Discrete Fourier Transform) for estimation. The algorithm uses a short data window for real-time transmission line protection. Also, from the calculated arc voltage amplitude, a decision can be made whether the fault is permanent or transient. The proposed algorithm is tested through computer simulation to show its effectiveness.

A Study on the Fault Detection and Discrimination of Transmission Line using Fault-generated High Frequency Signals (고주파를 이용한 송전선로의 사고 검출 및 판별에 관한 연구)

  • Lee, Dong-Jun;Kim, Chul-Hwan;Kim, Il-Dong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.8
    • /
    • pp.924-931
    • /
    • 1999
  • Most conventional protection relays are based on processing information in the spectrum that is close to or at power frequency. It is, however, widely known that faults on transmission lines produce frequency components of a wide range. High frequency signals caused by sudden changes in system voltage that occurs in the immediate post-fault period are generally outside the bandwidth of receptibility of most protection scheme. In this respect, a specially designed stack tuner is connected to the coupling capacitor of CVT, in order to capture the high frequency signals. Digital signal processing is then applied to the captured information to determine whether the fault is inside or outside the protected zone, and to discriminate the fault type. In this paper, modal transform is not applied to fault generated signals, because signals which are converted by modal transform are not have an information of each phase any longer. Instead, using peak voltage value of data windows is able to discriminate fault type. The paper concludes by presenting fault detection and discrimination of various faults on transmission line which are based on extensive simulation studies carried out on a typical 154kV Korean transmission line, using the EMTP software.

  • PDF

Analysis of the Competitiveness of Broadband over Power Line Communication in Korea

  • Jeong, Gi-Cheol;Koh, Dae-Young;Lee, Jong-Su
    • ETRI Journal
    • /
    • v.30 no.3
    • /
    • pp.469-479
    • /
    • 2008
  • This study analyzes factors affecting the competitiveness of broadband over power line communication (BPLC) and predicts demand for the service, based on quantitative information about consumer preferences drawn from a survey of Korean consumers. Findings from the estimation suggest that, although consumers value some beneficial features of BPLC, to be competitive the speed and stability of its data transmission needs to be improved. Moreover, on the basis of a market simulation, we expect BPLC to occupy only a small portion of Korea's Internet access market in the future, a finding we expect would hold true for other developed countries whose Internet access markets are already mature.

  • PDF

The Characteristic of Data Transmission for Power Line Communication using an AC Arrester for Electric Railway (전철 피뢰기를 이용한 전력선 통신 데이터 전송 특성)

  • Kim, Jae-Moon;Ahn, Seung-Ho;Kim, Yang-Su;Kim, Chul-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.497-502
    • /
    • 2012
  • Power line communication(PLC) is a kind of communication technology, was made use of controling a frequency narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. This paper deals with the PLC of electric railway using capacitive signal coupler. An AC arrester for catenary is used as a capacitive signal coupler, has the characteristic of capacitor. As a result of field test, a messenger wire used PLC contain much of conducted noise about overall frequency band and also signal attenuation rate increased with increasing frequency between two points. and the communication speed of PLC used messenger wire is 793kbps at a distance of 40m. Experimental results show the possibility of PLC using a messenger wire and an AC arrester for catenary at electric railway.

A study on the comparison/analysis between the fault of transmission line and the LPATS lightning data (송전선로 고장과 LPATS 낙뢰자료 DB와의 비교분석에 관한 연구)

  • Woo, J.W.;Shim, E.B.;Kim, J.B.;Lee, G.W.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2073-2075
    • /
    • 1999
  • To study the basic research of the lightning parameter for power system operation. LPATS(Lightning Position and Tracking System) has been introduced since 1995 in KEPCO. We have developed the lightning parameter analysis program. We obtained the various statistical distribution of lightning current parameters from 1995 by this program. In this paper, we describe the results on the comparison/analysis between the fault of transmission line and the LPATS lightning data.