• Title/Summary/Keyword: power filtering

Search Result 413, Processing Time 0.029 seconds

Harmonic and Interhamonic Detection and Estimation of Power Signal using Subband MUSIC/ESPRIT (부밴드 MUSIC/ESPRIT를 이용한 전력신호 고조파 및 중간고조파 검출 및 추정)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.149-158
    • /
    • 2015
  • This paper proposes a subband filtering technique to the MUSIC and the ESPRIT algorithm for estimating the magnitude and frequency of the harmonics of power signal. In proposed method, the input power signal is decomposed to the odd harmonics and the even harmonics respectively by the filter bank system. The amplitude and the frequency estimation of the decomposed harmonics are carried out using the MUSIC and the ESPRIT method. Subband filtering can reduce the autocorrelation matrix size of input data, and spectrum leakage between adjacent harmonics. Therefore, this subband technique has advantage in computational cost and estimation accuracy compared to fullband MUSIC and ESPRIT. To demonstrate the performance of the method, computer simulations are performed to the synthesized input signal, and experiment results are compared in subband and fullband cases.

Low-Power Block Filtering Architecture for Digital IF Down Sampler and Up Sampler (디지털 IF 다운 샘플러와 업 샘플러의 저전력 블록 필터링 아키텍처)

  • 장영범;김낙명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.743-750
    • /
    • 2000
  • In this paper, low-power block filtering architecture for digital If down sampler and up sampler is proposed. Software radio technology requires low power and cost effective digital If down and up sampler. Digital If down sampler and up sampler are accompanied with decimation filter and interpolation filter, respectively. In the proposed down sampler architecture, it is shown that the parallel and low-speed processing architecture can be produced by cancellation of inherent up sampler of block filter and down sampler. Proposed up sampler also utilizes cancellation of up sampler and inherent down sampler of block filtering structure. The proposed architecture is compared with the conventional polyphase architecture.

  • PDF

Analysis on Power Generation Characteristics of a Vehicle Rooftop Photovoltaic Module with Urban Driving Conditions (도심 주행 조건에 따른 차량 탑재 태양광모듈의 발전특성 분석)

  • Jeon, Seonwoo;Choung, Seunghoon;Bae, Sungwoo;Choi, Jaeyoung;Shin, Donghyun
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.79-86
    • /
    • 2020
  • This study examines the power generation characteristics of a vehicle rooftop photovoltaic module with urban driving conditions. Actual test data with an illuminometer and a thermometer were used to analyze the power generation characteristics of the vehicle rooftop photovoltaic module. In addition, the power generation characteristics were analyzed in terms of urban driving conditions, irradiance, ambient temperature, and photovoltaic module temperature. This study also analyzes the power generation characteristics of the vehicle rooftop photovoltaic module with urban driving conditions through a wavelet transform filtering method. The power generation characteristics of the vehicle rooftop photovoltaic module with urban driving conditions depend on the change in irradiance rather than that in photovoltaic module temperature.

Ventricle Image Restoration and Enhancement with Multi-thresholding and Multi-Filtering

  • Ryu, Kwang-Ryol;Jung, Eun-Suk
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.2
    • /
    • pp.231-234
    • /
    • 2009
  • Speckle noise reduction for power Doppler ventricle coherent image for restoration and enhancement using Fast Wavelet Transform with multi-thresholding and multi-filtering on the each subbands is presented. Fast Wavelet Transform divides into low frequency component image to high frequency component image to be multi-resolved. Speckle noise is located on high frequency component in multi-resolution image mainly. A Doppler ventricle image is transformed and inversed with separated threshold function and filtering from low to high resolved images for restoration to utilize visualization for ventricle diagnosis. The experimental result shows that the proposed method has better performance in comparison with the conventional method.

A Fault Detection Method for Control Rod Drive Mechanisms in Nuclear Power Plants via $H_\infty$ Filtering ($H_\infty$ 필터를 이용한 원자력발전소 제어봉구동장치의 고장 검출)

  • Kim, Seok-Ju;Kim, Chun-Gyeong;Lee, Jong-Mu;Gwon, Sun-Man;Park, Min-Guk
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.571-574
    • /
    • 2003
  • This paper proposes a detection method for mechanically stuck control rod drive mechanism (CRDM) faults. During the normal operation of a CRDM, disturbance voltage is induced due to the change of the airgap flux between the stator and the armature of a CRDM. This disturbance voltage is estimated by using $H_\infty$ filtering method, and generalized plant is used in linear fractional transform (LFT) framework. $H_\infty$ filtering is described and solved in terms of linear matrix inequalities (LMIs). Simulation results are shown.

  • PDF

A Study on the Alarm Processing System for Fossil Power Plant (화력발전소 경보처리 시스템에 관한 연구)

  • ;;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.32B no.8
    • /
    • pp.1045-1056
    • /
    • 1995
  • The purpose of multiple alarm processing is to give the operator the correct information and perception of the malfunction present in the plant. In this thesis, an APS(Alarm Processing System) is studied for fossil power plants. This APS is based on a cause-consequence trees in the knowledge representation aspect for alarm and plant and adapts alarm filtering methods using fired time information in the decision aspect. Through the cause-consequence trees and filtering methods, the Alarm Processing System finds the cause alarm among the fired multiple alarms and calculates the cause degree which represents the possibility of a fault occurring in the instruments of the plant with the information of fired alarm. The knowledge base is built via interviews and questionaries with the expert operators on the Seoul power plant unit 4. Finally, the validity of the studied APS is shown via simulations.

  • PDF

An Improved Multi-Tuned Filter for High Power Photovoltaic Grid-Connected Converters Based on Digital Control

  • Sun, Guangyu;Li, Yongli;Jin, Wei
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.160-170
    • /
    • 2018
  • For high power photovoltaic (PV) grid-connected converters, high order filters such as multi-tuned filters and Traps+RC filters with outstanding filtering performance have been widely researched. In this paper, the optimization of a multi-tuned filter with a low damping resistance and research on its corresponding control scheme have been combined to improve the performance of the proposed filter. Based on the characteristics of the switching harmonics produced by PWM, the proposed filter is optimized to further improve its filtering performance. When compared with the more common Traps+RC filter, the advantages of the proposed filter with low damping resistances in attenuating the major switching harmonics have been demonstrated. In addition, a simpler topology and reduced power loss can be achieved. On the other hand, to make the implementation of the proposed filter possible, on the base of the unique frequency response characteristic of the proposed filter, a digital single-loop control scheme has been proposed. This scheme is a simple and effective means to suppress the resonance peak caused by a lack of damping. Therefore, a smaller volume, better efficiency of the proposed filter, and easy implementation of the corresponding control scheme can be realized. Finally, the superiority of the proposed filter topology and control scheme is verified in experiments.

contactless power conversion system using the Boost converter (승압형 컨버터를 활용한 비접촉식 전력변환 시스템)

  • Lee S. J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.214-217
    • /
    • 2003
  • The connectorless power supply system on that multi-contact causes confidence when the wiring reconstructed in the rear. As you see above, contact points between sets and indoor space cause inferior function of audio frequency so it needs to be eliminated. This paper explains the structure of connectorless power supply to supply the system with power crossing the air gap in the part of inductively in the connectorless power supply of both magnetic and electrical model. To get maximum output of electrical load, compensating capacitor compensates to show inter-inductance, lequeage-inductance reducing the track-inductance and access the conditions for resonance. At that time it accesses the maximum electric power. The small change of the value of compensating capacitor causes the changes of maximum electric power. Here the power electronics technology is used not only in the industrial machinery but also in the home appliances so the switching power supply is used to actualize the miniaturization, lightweight, and high efficiency. Generally the condenser input methods are widely used in the rectification circuit of switching power supply, but condenser input method generate great quantity of high frequency components because with this method the current flows in the power input filtering condenser only around value of peak of ac input voltage. To solve these problems, installation of power factor improve circuit on the front of filtering capacitence was considered. Several methods were suggested regarding, but the active filter method which makes smalliging and highly power factor possible are the produce main stream. IC for power factor improvement can be utilized by CMOS process proposing low power consumption. When the high power factor is considered seriously in the power factor improvement circuit, active filter method is selected. In the active filter method, the boost converter is used. Regarding this ·the boost converter is needed.

  • PDF

Design of 20 W Class-E Amplifier Including Protection for Wireless Power Transmission at ISM 13.56 MHz (보호 회로를 포함한 무선 전력 전송용 ISM 13.56 MHz 20 W Class-E 앰프 설계)

  • Nam, Min-Young;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.6
    • /
    • pp.613-622
    • /
    • 2013
  • In this paper, an inductive clamping class-E power amplifier has been tested for wireless power transmission at ISM band, 13.56 MHz. The implemented power amplifier is designed to operate stably without destroying power transistor in wireless power transmission system which basically keeps not to align between a transmitting antenna and a receiving antenna. The power amplifier is also designed to enhance harmonic filtering characteristic. The amplifier was tested with a DC supply voltage of 28 V and input power of 25 dBm at 13.56 MHz. The test results show the output power level of 43 dBm, the difference power level between fundamental frequency and second harmonic frequency of more than 55 dBc, the dc current consumption of 830 mA, and the high power-added efficiency of 85 %. Finally, the implemented power amplifier operated normally with 830 mA DC current consumption from 28 V source when the two antennas were aligned, and the power transmission was successful. But when the two antennas were not aligned, its DC current consumption automatically decreased down to 420 mA to protect the switching transistor.