• Title/Summary/Keyword: power distribution line

Search Result 812, Processing Time 0.032 seconds

Anti-islanding method for distributed PV generation systems (분산형 태양광발전시스템의 단독운전 검출기법)

  • Hwang, In-Ho;Ahn, Kyo-Sang
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.64-67
    • /
    • 2005
  • Many anti-islanding methods have been developed and tested in pratice. Generally, it seems to be possible to include effective and reliable anti-islanding methods in the PV inverter However, it is difficult to detect islanding phenomenon in the case of multiple systems in the same distribution line. In this paper, the islanding possibility of distributed PV generation system is analyzed and discussed to detect islanding phenomenon.

  • PDF

SERVICE RESTORATION OF POWER DRSTRIBUTION SYSTEM IN CONSIDERATION OF PROTECTIVE DEVICES (보호기기를 고려한 배전계통 복구방안)

  • Lee, Seung-Jae;Kim, Tae-Hyung;Yoon, Jin-Young;Kim, Kuk-Hun;Kim, Hak-Moo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.48-50
    • /
    • 1993
  • One of the most important functions in the distribution automation is the service restoration. This paper proposes the new method which considers not only constraints of voltage, line current and bank capacity but also the operating characteristics of protective devices such as OCR and reclosers.

  • PDF

Study on Operation Method for Distribution Line Connection using Active Phase Controller (능동위상제어기를 이용한 배전선로 연계 운전방법에 대한 연구)

  • Kim, Soo-Yeon;Jeong, Da-Woom;Park, Sung-Jun;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.326-327
    • /
    • 2019
  • 본 논문은 분산전원의 증가로 복잡해진 배전 계통의 효율적인 운영을 위해 배전선로의 재구성을 연구하며, 각 배전선로를 연계하기 위해 능동위상제어기를 이용하여 배전선로간의 연계방안을 제안한다. 능동위상제어기의 개념을 설명하고, 배전 선로의 연결을 위해 연계 지점의 전압 크기와 위상을 동기화하는 방법을 제안한다. 제안한 방법은 시뮬레이션을 통해 검증한다.

  • PDF

Introduction of KEPCO's distribution class SFCL fabricated for verification test (실증시험용 배전급 초전도 한류기의 특성 평가 및 운전 시험)

  • Yim, Seong-Woo;Park, Chung-Ryul;Yu, Seung-Duck;Kim, Hye-Rim;Hyun, Ok-Bae;Park, Kwon-Bae;Sim, Jung-Wook;Lee, Kyoung-Ho;Oh, Ill-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.294_295
    • /
    • 2009
  • Superconducting fault current limiter (SFCL) is an power device of a novel concept. While SFCLs generate no ohmic loss during the operation carrying normal currents, they can limit fault currents very fast making large impedance by their quench characteristics. In 2006, KEPCO has developed a distribution class hybrid type SFCL by a collaborative research project with LS industrial systems. The SFCL has merits in practical and economical points of view. In the SFCL, the superconductor just plays a role of a fault detector and the current limiting is completed by the other current limiting element made of normal metals throu호 the line commutation. As a result, the required amounts of superconductors can be reduced considerably. Consequently, the hybrid SFCL can be fabricated with small size and cost, maintaining perfect current limiting performance. Currently, KEPCO is carrying out a research project at Gochang power test center for the purpose of the verification test of the 22.9 kV/ 630 A class SFCL for the practical application in real grid. Through the project, a long term operational test and fault current test will be done. In this paper, the back ground of development and installation of the SFCL will be explained and the operation plan of the SFCL for the verification test is also introduced.

  • PDF

Application Method and EMTP-RV Simulation of Series Resonance Type Fault Current Limiter for Smart Grid based Electrical Power Distribution System (스마트 그리드 배전계통을 위한 직렬 공진형 한류기 적용 방법 및 EMTP-RV 시뮬레이션 연구)

  • Yun-Seok Ko;Woo-Cheol Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.2
    • /
    • pp.361-370
    • /
    • 2024
  • In this paper, a method was studied for applying a series resonant type fault current limiter that can be manufactured at low cost to the smart grid distribution system. First, the impact of the harmonic components of the short-circuit fault current injected into the series resonance circuit of the fault current limiter on the peak value of the transient response was analyzed, and a methodology for determining the steady-state response was studied using percent impedance-based fault current computation method. Next, the effectiveness of the method was verified by applying it to a test distribution line. The test distribution system using the designed current limiter was modeled using EMTP_RV, and a three-phase short-circuit fault was simulated. In the fault simulation results, it was confirmed that the steady-state response of the fault current accurately followed the design target value after applying the fault current limiter. In addition, by comparing the fault current waveform before and after applying the fault current limiter, it was confirmed that the fault current was greatly suppressed, confirming the effect of applying the series resonance type current limiter to the distribution system.

Smart Panel Board for EV Standard Chargers and Its Control Method (전기자동차 완속충전기용 스마트 분전반 및 그 제어방법)

  • Kim, Myeong-Soo;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.511-521
    • /
    • 2014
  • This study proposes an electric vehicle (EV) smart panel board and its control method on the basis of charging scheduling. The proposed system consists of batteries, a three-phase battery charger, three single-phase inverters, transfer switches for electric power distribution, and a controller. The three-phase battery charger usually charges the batteries at midnight when electric rates are cheap and in light load. When the electric power consumption of the EV standard chargers connected to one phase of the power line is relatively large or when a blackout occurs, the electric power stored in the battery is supplied by discharging through the inverters to the EV standard chargers. As a result, the value of peak load and the charging electric power quantity supplied from a utility grid are reduced, and the current unbalance is improved. The usefulness of the proposed system is confirmed through simulations, experiments, and case studies.

The Design of Rectangular Microstrip Patch Array Antenna with Micorstrip Feed Line Network (마이크로스트립 급전 회로망을 갖는 구형 마이크로스트립패치어레이 안테나의 설계)

  • Park, Doo-Seok;Hong, Ui-Seok;Ko, Young-Hyuk
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.2
    • /
    • pp.39-46
    • /
    • 1990
  • In this paper, Rectangular microstrip patch array antenna. relative current of which is distributed to 1:2:2:1, is designed and fabricated by using Tschebyscheff's polynominal expression and is verified by theoretical analysis and experiment. Seeking for more accurate resonant frequency, an equivlent network, which is consisted including feed line and power distribution line, is analyzed by using the analysis method of transmission line mode. As a result of their comparison and examination, such as resonant frequency by fringing effects, by return loss, by experiment, it is conformed that errors are not barely and agreed with each other. is also agreed with a measured values.

  • PDF

Dynamic Thermal Rating of Transmission Line Based on Environmental Parameter Estimation

  • Sun, Zidan;Yan, Zhijie;Liang, Likai;Wei, Ran;Wang, Wei
    • Journal of Information Processing Systems
    • /
    • v.15 no.2
    • /
    • pp.386-398
    • /
    • 2019
  • The transmission capacity of transmission lines is affected by environmental parameters such as ambient temperature, wind speed, wind direction and so on. The environmental parameters can be measured by the installed measuring devices. However, it is impossible to install the environmental measuring devices throughout the line, especially considering economic cost of power grid. Taking into account the limited number of measuring devices and the distribution characteristics of environment parameters and transmission lines, this paper first studies the environmental parameter estimating method of inverse distance weighted interpolation and ordinary Kriging interpolation. Dynamic thermal rating of transmission lines based on IEEE standard and CIGRE standard thermal equivalent equation is researched and the key parameters that affect the load capacity of overhead lines is identified. Finally, the distributed thermal rating of transmission line is realized by using the data obtained from China meteorological data network. The cost of the environmental measurement device is reduced, and the accuracy of dynamic rating is improved.

Design and Application of Power Line Communication Module for V2G Conforming with International Standard for Electric Vehicle Charging Infrastructure (EV 충전인프라를 위한 국제표준에 부합하는 V2G용 전력선통신모듈 설계 및 응용)

  • Kim, Chul-Soo;Baek, Soo-Whang
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.6
    • /
    • pp.1183-1190
    • /
    • 2018
  • The environmental regulations are being strengthened all over the world, and the introduction of electric vehicles are actively being considered to cope with them effectively. It is essential to establish a charging infrastructure, which is an essential element of electric vehicle distribution. In this paper, power line communication technology essential for smart charging infrastructure is studied. A control board capable of achieving a physical layer speed of 10Mbps and a TCP/IP layer of 4.5Mbps, which conforms to the ISO/IEC 15118 international standard, and a control board mounted on the board and compliant with international standards. We have developed a software solution to perform functions for linking. In addition, in order to be applied to the combo-type DC fast charger, the hardware was designed to meet the industrial environment standard and the V2G communication module was developed by integrating it with the software solution.

Safeguard system using distribution line and telecommunication network for controlling aimless behavior in senile elderly patients

  • Yamamoto, Hiromi;Wakamatsu, Hidetoshi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10b
    • /
    • pp.885-890
    • /
    • 1988
  • This is a successive study of the development and application of an electronic safeguard system for elderly men (senile dementia patients) who wander without purpose because of declined mental capability, while retaining their physical ability. The new safeguard system is designed with some additional functions on the basis of the previously developed system. Firstly, alarms are designed not to disturb other patients at night, so that informations about doors from which the patients go out may be transmitted to helpers individually by radio paging system. Secondly, the system hardware can be set up anywhere without laying particular signal transmission cables, provided that there exist AC power distribution lines for the utilization as a transmission line of signals to alarm indicators. Thirdly, it is possible to have a grasp of the whole states of the safeguard systems at the center of operation by monitoring the operational state of each system with a necessary data acquisition according to its instruction through telecommunication network. Thus, each safeguard system can be economically supplied to the special nursing homes and the helpers are ensured more released from physical and psychological burdens so that they can devote themselves to the care of senile elderly men, thereby improving their patients' comfort and human dignity.

  • PDF