• 제목/요약/키워드: power delivery

검색결과 428건 처리시간 0.028초

V-t 특성 분석에 의한 고체 거시계면의 수명 평가 (Prediction of Life-Time on the Macroscopic Interface between Solid Materials with Analysis of V-t Characteristics)

  • 오재한;이경섭;배덕권;김충혁;이준웅
    • 한국전기전자재료학회논문지
    • /
    • 제13권7호
    • /
    • pp.607-611
    • /
    • 2000
  • The characteristics on the interface between Epoxy and EPDM which are materials of the underground insulation systems of power delivery have studied. The breakdown strength of specimens are observed by applying high AC voltage at the room temperature. The breakdown times under the constant voltage below the breakdown voltage were gained. As constant voltage is applied the breakdown time is proportion to the breakdown strength. The life exponent n is gained by inverse power law and the long breakdown life time can be evaluated. AC breakdown strength and life time is improved by oiling to the interface. When the low viscosity oil is spread interface has the highest life time.

  • PDF

디지탈 보호계전기 성능 시뮬레이터에 관한 연구 (A Study on the Performance Simulator of Digital Protective Relay)

  • 최상봉;문영환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.152-155
    • /
    • 1993
  • Protective Relay in power system play a prominent part in minimizing power delivery interruptions and help to get a fast and secure restoration when a failure occurs. In order to meet the higher functional requirements in power system, the performance tests on response characteristic of protective relay is essential to ensure reliability. The purpose of this study is as follows: In order to evaluate performance of protective relay, it is intended to develop performance of digital protective relay simulator which is composed of digital protective relay part, behaviour analysis part, waveform generation part and simulation program to simulate pour system in detail.

  • PDF

Smart Grid and Its Implications for Electricity Market Design

  • Kim, Seon-Gu;Hur, Seong-Il;Chae, Yeoung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.1-7
    • /
    • 2010
  • Recently, smart grid has been considered a very important new energy delivery technology, and one that can help ensure a cleaner environment by making use of information and communication technology (ICT) in countries around the world. The many technological benefits smart grid offers is expected to bring about a huge change in the electric energy supply chain. In particular, smart grid with advanced ICT is likely to allow market agents to participate in the decision-making process in the restructured electricity industry, easily facilitating Homeostatic Utility Control. In this paper, we examine smart grid as a market externality, and then illustrate issues from the commercial market perspective as it relates to electricity market design. Finally, our paper identifies some of the impacts of smart grid on electricity market design, which may possibly be incorporated into the evolution of the electricity market, thus ensuring market efficiency.

Small-IoT 환경에서 이기종 네트워크를 활용한 스마트 모바일 단말의 에너지 효율적 실시간 컴퓨팅 기법 (Energy-efficient Real-time Computing by Utilizing Heterogenous Wireless Interfaces of the Smart Mobile Device in Small-IoT Environments)

  • 임성화
    • 반도체디스플레이기술학회지
    • /
    • 제20권3호
    • /
    • pp.108-112
    • /
    • 2021
  • For smart mobile devices, the wireless communication module is one of the hardware modules that consume the most energy. If we can build a multi-channel multi-interface environment using heterogeneous communication modules and operate them dynamically, data transmission performance can be highly improved by increasing the parallelism. Also, because these heterogeneous modules have different data rates, transmission ranges, and power consumption, we can save energy by exploiting a power efficient and low speed wireless interface module to transmit/receive sporadic small data. In this paper, we propose a power efficient data transmission method using heterogeneous communication networks. We also compared the performance of our proposed scheme to a conventional scheme, and proved that our proposed scheme can save energy while guaranteeing reasonable data delivery time.

Configurations of AC and DC-type Quality Control Center for a New Distribution System FRIENDS

  • Hayashi Yusuke;Saisyo Masaki;Ise Toshifumi;Tsuji Kiichiro
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.497-501
    • /
    • 2001
  • Unbundled power quality service is paid much attention under the circumstances of deregulation and diversification of needs of customers for quality and price of electric power. Moreover, distributed generators (DGs) such as photovoltaic generations and wind turbines will be introduced to distribution system more and more, and reverse flow of active power has possibility to cause new problems in the distribution system such as voltage rise of distribution line and protection problem. Flexible, Reliable and Intelligent Electrical eNergy Delivery System, which is called FRIENDS, has been proposed as one of promising distribution system for such requirements, and intensive studies are under way. One of features of the system is introducing Quality Control Center (QCC) into the system for unbundled power quality service and easy installation of DGs. Two types of QCCs for such purposes are proposed, and simulation results are shown in this paper.

  • PDF

A Wire-overhead-free Reset Propagation Scheme for Millimeter-scale Sensor Systems

  • Lee, Inhee;Bang, Suyoung;Kim, Yejoong;Kim, Gyouho;Sylvester, Dennis;Blaauw, David;Lee, Yoonmyung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권4호
    • /
    • pp.524-533
    • /
    • 2017
  • This paper presents a novel reset scheme for mm-scale sensing systems with stringent volume and area constraints. In such systems, multi-layer structure is required to maximize the silicon area per volume and minimize the system size. The multi-layer structure requires wirebonding connections for power delivery and communication among layers, but the area overhead for wirebonding pads can be significant. The proposed reset scheme exploits already existing power wires and thus does not require additional wires for system-wide reset operation. To implement the proposed reset scheme, a power management unit is designed to impose reset condition, and a reset detector is designed to interpret the reset condition indicated by the power wires. The reset detector uses a coupling capacitor for the initial power-up and a feedback path to hold the developed supply voltage. The prototype reset detector is fabricated in a $180-{\mu}m$ CMOS process, and the measurement results with the prototype mm-scale system confirmed robust reset operation over a wide range of temperatures and voltages.

오늘날의 고성능 TBM과 선진 장비조달 방안 (Modern High-Power TBM with Advanced Procurement System)

  • 지왕률
    • 터널과지하공간
    • /
    • 제23권3호
    • /
    • pp.161-168
    • /
    • 2013
  • 세계적으로 Modern High-Power TBM을 이용한 터널공사가 점점 많아지고 있다. 특히 오늘날의 고성능 TBM의 개발로 많은 터널공사에서 성공적인 결과를 가져왔으며, TBM 동력의 향상과 커터 등 면판설계 기술의 발달, 및 TBM 굴진율 예측 소프트 웨어의 사용 등으로 터널공사의 자동화, 기계화가 이뤄 졌으며, TBM 장비조달은 OPP 방식을 이용한 발주자 직접 구매 방식이 TBM 선진국에서 효과적으로 사용되고 있다. 최근 많은 나라에서 환경 민원 등의 문제로 인해 도심지의 발파공법사용이 금지되어 TBM을 이용한 터널의 기계화 시공이 세계적인 추세이다.

Energy Efficient Cross Layer Multipath Routing for Image Delivery in Wireless Sensor Networks

  • Rao, Santhosha;Shama, Kumara;Rao, Pavan Kumar
    • Journal of Information Processing Systems
    • /
    • 제14권6호
    • /
    • pp.1347-1360
    • /
    • 2018
  • Owing to limited energy in wireless devices power saving is very critical to prolong the lifetime of the networks. In this regard, we designed a cross-layer optimization mechanism based on power control in which source node broadcasts a Route Request Packet (RREQ) containing information such as node id, image size, end to end bit error rate (BER) and residual battery energy to its neighbor nodes to initiate a multimedia session. Each intermediate node appends its remaining battery energy, link gain, node id and average noise power to the RREQ packet. Upon receiving the RREQ packets, the sink node finds node disjoint paths and calculates the optimal power vectors for each disjoint path using cross layer optimization algorithm. Sink based cross-layer maximal minimal residual energy (MMRE) algorithm finds the number of image packets that can be sent on each path and sends the Route Reply Packet (RREP) to the source on each disjoint path which contains the information such as optimal power vector, remaining battery energy vector and number of packets that can be sent on the path by the source. Simulation results indicate that considerable energy saving can be accomplished with the proposed cross layer power control algorithm.

응급의료 전달체계의 충실 방안 (A Study in an Effective Programs for Emergency Care Delivery System)

  • 권숙희
    • 한국보건간호학회지
    • /
    • 제9권1호
    • /
    • pp.83-102
    • /
    • 1995
  • As the society is being industrialized, the fast-paced economic development that has caused substantial increase in cerebrovascular and coronary artery diseases and the industrial development and increased use of means of transportation have resulted in the rapid rise of incidents in external injuries as well. So the pubic has become acutely aware of the need for fast and effective emergency care delivery system. The goal of emergency care delivery system is to meet the emergency care needs of patients. The emergency care delivery system is seeking to efficiently satisfy the care needs of people. Therefore the purpose of this study is designed to develop an effective programs for emergency care delivery system in Korea. The following specific objectives were investigated. This emergency care delivery system must have the necessary man power, for transfering the patients, communication net work, and emergency care facilities. 1) Man power Emergency care requires n0t only specialized traning in the emergency treatment but also knowledge and experience i11 other related area, so emergency care personnel traning program should be designed in order to adapt to the specific need of emergency patients. It will be necessary to ensure professional personnel who aquires the sufficient traning and experience for emergency care and to look for legal basis. We have to develop re-educational programs for emergency nurse specialist. They should be received speciality of emergency nursing care so that they will work actively and positively in emergency part. Emergency medical doctor and nurse specialist should be given an education which is related in emergency and critical care. Emergency care personnel will continue to provide both acute and continuing care as partner with other medical team. 2) Transfering the patients. Successful management of pre-hospital care requires adequate traning for the emergency medical technician. Traning program should be required to participate in a actual first aids activites in order to have apportunities to acquire practical skills as well as theoretical knowledge. The system of emergency medical technician should be remarkablly successful with first responder firefighters. Establishing this system must add necessary ambulances operating at any given time. It will be necessary to standardize the ambulance size and equipment. Ambulance should be arranged with each and every fire station. 3) Communication net work. The head office of emergency commumication network should be arranged with the head office of fire station in community. It is proposed that Hot-line system for emergency care should be introduce. High controlled ambulance and thirtial emergency center should simultaneously equip critical-line in order to communication with each other. Ordinary ambulance and secondary emergency facility should also simultaneously equip emergency-line in order to communication with each other. 4) Emergency care facilities. Primary emergency care facilities should be covered with the ambulatory emergency patients-minor illness and injuires. Secondary emergency care facilities should be covered with the emergency admission patients. Third emergency care center should be covered with the critical patients who need special treatments and operation. Secondary and third emergency care facilities should employ emergency medical doctor and emergency nurse specialist to treat in-patients with severe and acute illness and multiple injuires. It should be fashioned for a system of emergency facilities that meets emergency patients needs. Provide incentives for increased number of emergency care facilities with traning in personal/clinical emergency care. 5) Finance It is recommended to put the finance of a emergency care on a firm basis. The emergency care delivery system should be managed by the government or accreditted organizations. In order to facilitate this relevant program the fund is needed for more efficient and effective emergency researchs, service, programs, and policy. 6) Gaining understanding and co-operation of pubic It is also important to undertake pubic education to improve understanding of first aids and C. P. R of individuals, communities and business. It is proposed that teachers and health officers be certified in C. P. R. The C. P. R education can be powerful influence save lives. Lastly appropriate emergency care information must be provided to the pubic for assisting them in choosing emergency care.

  • PDF

Prediction of Galloping Accidents in Power Transmission Line Using Logistic Regression Analysis

  • Lee, Junghoon;Jung, Ho-Yeon;Koo, J.R.;Yoon, Yoonjin;Jung, Hyung-Jo
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.969-980
    • /
    • 2017
  • Galloping is one of the most serious vibration problems in transmission lines. Power lines can be extensively damaged owing to aerodynamic instabilities caused by ice accretion. In this study, the accident probability induced by galloping phenomenon was analyzed using logistic regression analysis. As former studies have generally concluded, main factors considered were local weather factors and physical factors of power delivery systems. Since the number of transmission towers outnumbers the number of weather observatories, interpolation of weather factors, Kriging to be more specific, has been conducted in prior to forming galloping accident estimation model. Physical factors have been provided by Korea Electric Power Corporation, however because of the large number of explanatory variables, variable selection has been conducted, leaving total 11 variables. Before forming estimation model, with 84 provided galloping cases, 840 non-galloped cases were chosen out of 13 billion cases. Prediction model for accidents by galloping has been formed with logistic regression model and validated with 4-fold validation method, corresponding AUC value of ROC curve has been used to assess the discrimination level of estimation models. As the result, logistic regression analysis effectively discriminated the power lines that experienced galloping accidents from those that did not.