• Title/Summary/Keyword: power conditioning

Search Result 1,094, Processing Time 0.023 seconds

A Microcomputer-Based Engine Performance Test System(I) (마이크로 컴퓨터를 이용(利用)한 엔진성능(性能) 측정장치(測定裝置) (I))

  • Min, Y.B.;Kim, Y.H.;Lee, K.M.;Huh, S.D.
    • Journal of Biosystems Engineering
    • /
    • v.11 no.1
    • /
    • pp.24-30
    • /
    • 1986
  • In order to collect the engine performance data accurately, rapidly and reliabily, the microcomputer-based engine performance test system was developed and tested. The system measures engine shaft torque and speed, fuel consumption, exhaust gas temperature, engine shaft power and fuel consumption ratio. The system consisted of 32 channels 8 bit A/D converter, time clock, dynamic strain amplifier and signal conditioning circuits to amplify and filter the electrical signal from transducers. Most of transducers were devised for low cost, easy setting and self-manufacturing. The system has been installed on a small kerosene engine (DAEDONG NA50B).

  • PDF

A Study of Thermodynamic Cyclic Characteristics of HFC-134a Automotive Air-Conditioner System (HFC-134a 자동차용 공조시스템의 열역학적 사이클 특성에 관한 연구)

  • Lee, K.H.;Won, J.P.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.1
    • /
    • pp.51-64
    • /
    • 1994
  • Analytical study on the thermodynamical cyclic behabiour and characteristics of HFC-l34a refrigerant for automotive air conditionser system for the replacement of existing CFC-12 has been carried out in this paper through development of system performance simulation program, expecially in the view point of system design considerations. The results indicate that HFC-l34a system will give a greater refrigerating capacity than CFC-12 if appropriate engineering measures such as proper codensers, flow controllers, etc., taken for certain operating conditions. The results, however, also show that the operating power for compression process increases over entire temperature range as a result of decreasing volumetric efficiency due to larger specific volume and increased discharging pressure. The present study results indicate that proper selection of condensing and evaporating temperature plus refrigerant control is very important performance factor to have better COP in the HFC-134a system design.

  • PDF

Analysis of the Low Frequency Ripple according to Power Conditioning System Topology and PMW Strategy (PCS 회로 및 PWM 방식에 따른 저주파 리플전류 분석)

  • Shin, Dong-Gun;Kim, Jong-Soo;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.258-259
    • /
    • 2007
  • 본 논문에서는 연료전지 시스템에서 발생하는 저주파 리플 전류의 발생 및 전달과정을 분석하고 PCS 회로 및 PWM방식에 따른 저주파 리플 영향을 비교 분석한다. 전압형 풀브리지 컨버터와 전류형 풀브리지 컨버터에서의 저주파 리플 전류 발생 양상을 시뮬레이션을 통하여 비교 분석한다.

  • PDF

Modeling of Fuel Cell Stack to Design of Power Conditioning System (PCS) for Fuel Cell Application (연료전지용 PCS 설계를 위한 연료전지 스택 모델링)

  • Ko, Jeong-Min;Kim, Jong-Soo;Kang, Hyun-Soo;Lee, Byoung-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.256-257
    • /
    • 2007
  • 본 논문에서는 연료전지용 PCS 설계 및 시뮬레이션 시 연료전지의 비선형 전원 특성에 의한 영향을 확인하기 위하여 고분자 전해질 연료전지 (PEMFC) 스택을 전기화학 방정식을 기반으로 모델링한다. 모델링된 연료전지 전원을 부스트 컨버터의 입력으로 활용하여 시뮬레이션을 수행한다.

  • PDF

DEVELOPMENT OF HOT CELL FACILITIES FOR DEMONSTRATION OF ACP

  • You, Gil-Sung;Choung, Won-Myung;Ku, Jeong-Hoe;Cho, Il-Je;Kook, Dong-Hak;Park, Seong-Won
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.02a
    • /
    • pp.191-204
    • /
    • 2004
  • The research and development of effective management technologies of the spent fuels discharged from power reactors are an important and essential task of KAERI. In resent several years KAERI has focused on a project named "development and demonstration of the Advanced spent fuel Conditioning Process (ACP) in a laboratory scale." The Facility for ACP demonstration consists of two Hot Cells and auxiliary facilities. It is now in the final design stage and will be constructed in 2004. After construction of the facility the ACP equipments will be installed in Hot Cells. The ACP will be demonstrated by some simulated spent fuels first and then by spent fuels.

  • PDF

feasibility Study in Application on Load Management of Cooling or Heating Systems (${\cdot}$난방 시스템의 부하관리 프로그램 적용 타당성 검토)

  • Son H.S.;Kim H.C.;Kim H.J.;Hur D.R.;Park J.B.;Shin J.R.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.686-688
    • /
    • 2004
  • We suggest that the core factor which can be established successfully pushing ahead with domestic load management program is finding and keeping management of controllable load resources. We know that load management is mostly the maximum demand power management and participation of DLC program. This paper suggests the way coping with load management suggesting model which air conditioning and heating load facilities are applied to DU program.

  • PDF

The study on a ship energy management system applied rechargeable battery

  • Jang, Jae-Hee;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.2
    • /
    • pp.202-207
    • /
    • 2014
  • Recently, the study of energy saving technology of ships begins in earnest, as energy saving policies are performed all around the world. SEMS (Ship Energy Management System) is one of the techniques to increase energy efficiency by applying to a independent system like a ship and offshore. SEMS is composed of Cooling Pump Control System (CPCS), Renewable Energy Emergency Power Control System (REEPCS), Load Control System (LCS), and Heating, Ventilation, and Air Conditioning System (HVACS). SEMS is enable to increase energy efficiency and achieve integrated management through the interlocking of each system. Especially, it is possible to improve the flexibility of the selection of the generator capacity in conjunction with a rechargeable battery and renewable energy. In this paper, SEMS applied rechargeable battery is proposed and simulated. By applying the rechargeable battery, it was confirmed that SEMS applied rechargeable battery can be operated at optimum efficiency of the generator.

Estimation of Noise Level near Cross Bow Fan by Measurements of Static Pressure. (정압을 이용한 직교류팬 주변의 소음 예측)

  • Kim, Jae-Won;Cho, Yong;Jung, Yoon-Young
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.1156-1161
    • /
    • 2001
  • A significant trial has been performed for estimation of noise level of a cross flow fan for air conditioning system. In general, measurements of noise level of machinery require rigorous equipment involving an anechoic chamber with precision gauges. The apparatus is expensive to utilize and is not easy to construct. In this work, we adopt static pressure sensing from an ordinary pressure transducer for prediction of noise level of a rotating fan. The present procedure is finding sound pressure from the static pressure by manipulating Light-Curle equation depicts noisy energy in terms of pressure on surfaces of noise generators. Sound power level near core unit of the fan is evaluated with the present methodology in a normal laboratory room without any sound absorbers. The method is easy and shows good prediction results compared with precise measurements by using microphones.

  • PDF

A Study on the Noise and Vibration Transmission Path of Rolling Pistion Type Rotary Compressor Using SEA (통계적 에너지 해석 기법에 의한 공조용 로타리 압축기의 소음 진동 전달 경로 해석)

  • Hwang, Seon-Woong;Jeong, Hyeon-Chul;Ahn, Byung-Ha;Jeong, Weui-bong;Kim, Kyu-Hwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.385.2-385
    • /
    • 2002
  • Hermetic rotary compressor is one of the most important components for air conditioning system since it has a great effect on both the performance and the noise and vibration of the system. Noise and vibration of rotary compressor is occurred due to gas pulsation during compression process and unbalanced dynamic force. In order to reduce noise and vibration, it is necessary to identify sources of noise and vibration and effectively control them. (omitted)

  • PDF

Experiment study of structural random loading identification by the inverse pseudo excitation method

  • Guo, Xing-Lin;Li, Dong-Sheng
    • Structural Engineering and Mechanics
    • /
    • v.18 no.6
    • /
    • pp.791-806
    • /
    • 2004
  • The inverse pseudo excitation method is used in the identification of random loadings. For structures subjected to stationary random excitations, the power spectral density matrices of such loadings are identified experimentally. The identification is based on the measured acceleration responses and the structural frequency response functions. Numerical simulation is used in the optimal selection of sensor locations. The proposed method has been successfully applied to the loading identification experiments of three structural models, two uniform steel cantilever beams and a four-story plastic glass frame, subjected to uncorrelated or partially correlated random excitations. The identified loadings agree quite well with actual excitations. It is proved that the proposed method is quite accurate and efficient in addition to its ability to alleviate the ill conditioning of the structural frequency response functions.