• Title/Summary/Keyword: power conditioning

Search Result 1,094, Processing Time 0.03 seconds

The Secondary LLC Series Resonant Converter for the Boost DC/DC Converter (변압기 2차측 LLC 직렬공진컨버터 적용 승압형 DC/DC 컨버터)

  • Lee Hyun-Kwan;Lee Gi-Sik;Chung Bong-Geon;Kong Young-Su;Kim Eun-Soo;Cha In-Su;Yoon Jeong-Phil
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.277-280
    • /
    • 2006
  • Recently, the high frequency isolated boost DC/DC converter has been widely used for the PCS (Power Conditioning System) system because of its small size and low cost. However, the high frequency isolated boost DC/DC converters applied the conventional voltage-fed converter and current-fed converter have the problems such as the high conduction losses and the surge voltage due to the high circulating current and the leakage inductance, respectively. To overcome this problems, in this paper the secondary LLC resonant converter is proposed, and the experimental results of the secondary LLC series resonant converter for boost DC/DC converter are verified on the simulation based on the theoretical analysis and the 1kW experimental prototype.

  • PDF

Parallel operation of grid-connected PV PCS (계통연계형 태양광 PCS의 병렬운전)

  • Lee K.O.;Jung Y.S.;So J.H.;Yu B.G.;Yu G.J.;Choi J.Y.;Choy I.
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.299-301
    • /
    • 2006
  • 계통연계형 태양광 시스템을 구성하고 있는 전력변환장치인 PCS(power conditioning system)는 일반적으로 그 내부에 입력전력 평활용 Capacitor, DC-DC Converter, DC link Capacitor, DC-AC Inverter 및 L-C Filter 등으로 구성된다. 이러한 태양광 시스템의 구성은 주로 태양광 어레이와 PCS의 DC-DC Converter 및 DC-AC Inverter의 수와 연결 방법에 따라 여러 가지로 구성할 수가 있다. 본 논문에서 제안할 시스템의 구성은 하나의 태양광 어레이를 다수의 계통연계형 태양광 PCS가 공유하는 형태인데, 이러한 시스템의 주요 장점은 첫째, 일사량에 따라 각각의 PCS가 모두 정격에서 운전하도록 하여 변환효율을 개선할 수 있다는 점과 둘째, 태양광 어레이의 용량 확장에 따른 PCS 장치의 용이한 확장성 그리고 셋째, 연결되어 있는 다수의 PCS 중 하나의 태양광 PCS가 고장으로 인하여 유지 및 보수가 필요할 때에도 그 외의 다른 정상적인 태양광 PCS는 지속적인 발전이 가능한 장점 등을 갖는다. 본 논문에서는 태양광 어레이의 출력을 공유하는 병렬운전용 태양광 PCS의 구성에 대하여 연구하고, 그 병렬운전기법을 제시하여 이에 대한 타당성을 시뮬레이션으로 검증하고자 한다.

  • PDF

A Simple Resonant DC Link Snubber-Assisted Bi-directional Three-phase PWM Converter for Battery Energy Storage Systems

  • Hiraki, Eiji;Nakaoka, Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.2B no.3
    • /
    • pp.133-139
    • /
    • 2002
  • In this paper, a prototype of an active auxiliary quasi-resonant DC link (QRDCL) snubber assisted voltage source bidirectional power converter (AC to DC and DC to AC) operating at zero voltage soft-switching (BVS) PWM nlode is presented for a Battery Energy Storage System (BESS). The operating principle of this QRDCL circuit and multifunctional control-based converter system, including PWM inverter mode in which energy flows from the battery bank to the three-phase utility-grid in addition to an active PWM converter mode in which energy flows from the utility-grid to the battery banks are described respectively by the control implementation on the basis of d-q coordinate plane transformation. The multifunctional operation characteristics of this three-phase ZVS PWM bi-directional converter with QRDCL is demonstrated fer a BESS under the power conditioning and processing schemes of energy supply mode and energy storage mode, and compared with a conventional three-phase hard switching PWM bi-directional converter for a BESS. The effectiveness of the three-phase ZVS PWM hi-directional converter with QRDCL is proven via the simulation analysis.

A study on performance test of water heat storage type heat-pump system using cooling tower heat source (냉각탑을 이용한 축열식 히트펌프시스템의 성능측정에 관한 연구)

  • Lee, Sang-Hoon;Park, Hyo-Sik;Han, Woo-Yong;Kim, Uk-Jung
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1099-1104
    • /
    • 2008
  • Recent year, mean energy consumptions of a people are higher than other country. And international oil price became over 120 dollar. This energy environment as well as energy war. Maybe, the Meteorological Administration is going to enforce scorching heatwave special report system from that come summer. Besides, 2008 summer, maximum demand power is expected by 64,240,000kW. The electric power equipment reserve rate appeared in to keep 12.5% level. Chilled water storage system witch is one of electric load administration system. Heat pump system used cooling tower heat recovery is advantage that use is possible to summer in small a public bath building. In this paper, we suggest that heat pump system by heat recovery using cooling tower when it is heating operation of ambient air temperature. To apply cooling tower heat recovery heat pump to chilled water heat storage type and achieved performance evaluation about operation. As a result, performance of heat pump system that about 121% in cooling mode, 138% in heating mode higher than KEPCO standard. And heating operation possible to ambient air temperature about $23^{\circ}C$, which of appear cooling tower outlet temperature about $13^{\circ}C$.

  • PDF

A study on the Cold-heat Storage System for Operation Status Monitoring of Showcase (쇼케이스 운전상태를 고려한 축냉시스템 적용타당성 연구)

  • Lee, Eun-Ji;Lee, Dong-Won
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1261-1266
    • /
    • 2008
  • Experimental study was performed to understand the operations of a showcase working in a discount store. Temperatures of evaporation, condenser were measured and also electric power consumption of compressor were measured. The purpose of this study is to application use of cold-heat storage systems operated the showcase. At the condition using ice storage system, the ice making process was operated during midnight being not needed the cooling of the showcase through the continuous running of the condenser unit. And then, the refrigerant was sub-cooled using stored cold-heat after being discharged from the air cooling condenser during the day time. The cooling performance was increased owing to the sub-cooling of refrigerant during day time, hence the running time of the compressor was effectively decreased. In other words, this study showed that power consumption during daytime can be transferred to the midnight for making use of the refrigerant sub-cooling. So the operating characteristics of the showcase system under various working conditions were analyzed and discussed.

  • PDF

Performance Evaluation of Heat Sink for Cooling of LED Projector (LED 프로젝터 방열용 히트싱크의 성능평가)

  • Lee, Kyoung-Yong;Choi, Young-Seok;Jeon, Dong-Soon;Kim, Seon-Chang;Son, Kwang-Eun
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

An Experimental Study on the Water Evaporation Conditions of the Enclosed Tank (밀폐용기내의 물의 저압 증발 최적조건에 관한 실험적 연구)

  • Kim, S.H.;Shin, Y.S.;Lee, Y.W.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.8 no.1
    • /
    • pp.41-47
    • /
    • 2004
  • Cooling towers are widely used not only for cooling products and equipment in manufacturing process but HVAC(Heating, Ventilation and Air Conditioning) system. As a cooling tower is the terminal apparatus which discharges heat from industrial process, the efficiency of heat exchange in the cooling tower greatly affects to the overall performance of a thermal system. In this paper, we constituted a new water cooling system by using a Latent heat of evaporation in an enclosed tank, and this system is consisted of an enclosed vacuum tank and water driven ejector system. Several experimental cases were carried out for improvement methods of high vacuum pressure and water cooling characteristics. The ejector performance was tested in case of water temperature variations that flows into the ejector. Based on the vacuum pressure by water driven ejector, the water cooling characteristics were investigated for the vaporized air condensing effects.

  • PDF

A Study on the Noise and Condensation Characteristics of Complex Structure Drainage Pipe Materials (복합 구조형 배수 배관재의 소음 및 결로 특성에 관한 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.72-77
    • /
    • 2016
  • The present study investigates noise and condensation characteristics of polyvinyl chloride (PVC), which is widely used for drainage piping materials, complex double structure by comparing to those of PVC single structure piping materials. In addition, effects of insulation on drainage noise has been measured experimentally. As the results of the experiments, noise reduction effect of PVC complex double structure is superior to that of PVC single structure in terms of elbow and vertical piping materials which are employed for drainage pipes of toilet bowls and bathtub. The insulation barely have effect on the noise reduction in case of the PVC single structure since there is almost no changes in noise occurrence even though the insulation is applied on both elbow and vertical piping materials. Temperature differences between inside and outside of the pipes have been measures for the PVC single and complex double structures as well. In consequence, outside temperature of the PVC complex double structure is higher than that of the PVC single structure. The condensation occurrence time of the PVC complex double structure shows a distinct difference from that of the PVC single structure, thus, the PVC complex double structure has outstanding effect on preventing the condensation.

Performance Characteristics of Refrigerant R170(Ethane) Refrigeration System Using Liquid-gas Heat Exchanger (액-가스 열교환기를 이용한 R170(에탄)용 냉동시스템의 성능 특성)

  • Ku, Hak-Keun
    • Journal of Power System Engineering
    • /
    • v.20 no.5
    • /
    • pp.78-85
    • /
    • 2016
  • This paper considers the influence of internal heat exchangers to the efficiency of a refrigerating system using R170. These liquid-gas heat exchangers(internal or suction-line heat exchangers) can, in some cases, yield improved system performance while in other cases they degrade system performance. A steady state mathematical model is used to analysis the performance characteristics of refrigeration system with internal heat exchanger. The influence of operating conditions, such as the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, to optimal dimensions of the heat exchanger is also analyzed in the paper. The main results were summarized as follows : the mass flowrate of R170, inner diameter tube and length of internal heat exchanger, and effectiveness have an effect on the cooling capacity, compressor work and RCI(Relative Capacity Index) of this system. Exception for the effect of inner diameter, the RCI of R170 with respect to refrigerant mass flowrate, the length and effectiveness of internal heat exchanger is about 2.1~3.3% higher than that of R13 at the same experimental conditions. With a thorough grasp of these effect, it is necessary to design the R170 compression refrigeration cycle using internal heat exchanger.

Cycle performance of refrigeration and air-conditioning system using the hydrocarbon refrigerant R-290 (탄화수소계 냉매 R-290을 사용하는 냉동.공조 장치의 사이클 특성에 관한 연구)

  • 박기원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.447-452
    • /
    • 1999
  • This paper describes the cycle performance of heat-pump system using R-22 and R-290. Experiments were performed in the smooth tube with inside diameter of 10.07mm and outside diameter of 12.07 mm and grooved inner tube having 75 fins with a height of 0.25mm Condensing temperatures were held constantly between 318K and 328 K while evaporating temperatures were varied from 257 K to 288 K mass velocities from 51 to $280 kg/m^2s$. From the experiments it was known that the evaporating temperature and condensing temperature had more affected by the compressor shaft power than the tube geometries. Cooling capacity of the R-22 and R-290 had similar values in the smooth and grooved inner tubes. The coefficient of performance(COP) was calculated using the compressor shaft power volumetric refrigeration capacity compression ratio and cooling capacity. The COP of the R-290 had slightly higher values than that of R-22 The major parameters affecting the heat pump cycle performance wee the refrigerant proper-ties and operating conditions rather than the geometric shapes of the heat exchanger

  • PDF