• Title/Summary/Keyword: power conditioning

Search Result 1,094, Processing Time 0.026 seconds

Thermal Instability of Fluid in a Slot between Two Vertical Permeable Walls (두개의 수직 다공성 벽면을 가진 좁은 간격에서의 유체의 열적 불안정성)

  • Sohn, Dong-Yun;Yoo, Jung-Yul;Lee, Taik-Sik
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.4
    • /
    • pp.215-222
    • /
    • 1984
  • An analytical study on the thermal instability of fluid in a vertical solt between two permeable walls has been carried out using fast converging power series solution method. For given values of prandtl number Pr and permeability paramter ${\sigma}$, the critical Grashof number $Gr_c$ and the critical wave number ac are found as eigenvalues of the problem formulated by the stability equations and the appropriate boundary conditions which are derived on the basis of linear stability theory. In the case of ${\sigma}\;>\;10^4$, the results approach those of solid boundary case, but in the case of ${\sigma}\;<\;10^3$, the decrease of $Gr_c$ and $a_c$become more prominent. In other words, the permeable walls cause the flow to be more unstable than the solid walls. This is considered to be due to the slip of the fluid on the wail, which decrease the friction force.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

Wind Power Grid Integration of an IPMSG using a Diode Rectifier and a Simple MPPT Control for Grid-Side Inverters

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.10 no.5
    • /
    • pp.548-554
    • /
    • 2010
  • In this paper, a 1.5 kW Interior Permanent Magnet Synchronous Generator (IPMSG) with a power conditioner for the grid integration of a variable-speed wind turbine is developed. The power-conditioning system consists of a series-type 12-pulse diode rectifier powered by a phase shifting transformer and then cascaded to a PWM voltage source inverter. The PWM inverter is utilized to supply sinusoidal currents to the utility line by controlling the active and reactive current components in the q-d rotating reference frame. While the q-axis active current of the PWM inverter is regulated to follow an optimized active current reference so as to track the maximum power of the wind turbine. The d-axis reactive current can be adjusted to control the reactive power and voltage. In order to track the maximum power of the wind turbine, the optimal active current reference is determined by using a simple MPPT algorithm which requires only three sensors. Moreover, the phase angle of the utility voltage is detected using a simple electronic circuit consisting of both a zero-crossing voltage detecting circuit and a counter circuit employed with a crystal oscillator. At the generator terminals, a passive filter is designed not only to decrease the harmonic voltages and currents observed at the terminals of the IPMSG but also to improve the generator efficiency. The laboratory results indicate that the losses in the IPMSG can be effectively reduced by setting a passive filter at the generator terminals.

The grid-connected bidirectional PCS technology of the ESS (에너지 저장장치의 계통 연계형 양방향 PCS 기술)

  • Ko, Bong-Woon
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1280-1287
    • /
    • 2019
  • Grid-connected bidirectional PCS(Power Conditioning System) technology is a technology for implementing distributed renewable energy smart grid. And it is always charged by using power collected from solar modules and commercial grid power among vast smart grid systems, and stored when needed.It is a hybrid energy storage device that allows power to be released into the low voltage system. To this end, a PV input power converter with MPPT function, a bidirectional power converter for battery charging and discharging, and a DC Link input are output to a 3 phase 380V AC system, and if nessary, the bidirectional DC/DC converter We designed and developed a PCS with three power converter structures composed of inverters that perform battery charging. Currently, this system is applied to the site of Jeju, which is vulnerable to power outages and fire accidents.

AN IN VITRO STUDY OF THE THERAPEUTIC EFFECT OF ARGON LASER IRRADIATION ON HYPERSENSITIVE ROOTS (과민성치근에 대한 Argon laser조사의 치료효과에 관한 실험적 연구)

  • Chang, Kap-Sung;Kim, Byung-Ok;Han, Kyung-Yoon
    • Journal of Periodontal and Implant Science
    • /
    • v.25 no.3
    • /
    • pp.668-678
    • /
    • 1995
  • In order to evaluate the therapeutic effect of argon laser irradiation on hypersensitive root, 60 mandibular premolars that had been extracted due to periodontal disease were treated by thorough scaling, root planing and root conditioning with tetracycline HCI(100mg/ml, 5 min.) for induction of hypersensitive root. Within middle one third of root mesial surface(30) or distal surface(30) was randomly irradiated by 0.5W-, 0.75W- and 1.0W-power for 2 minutes argon laser(HGM Inc., USA) with or without topical application of 1.23% acidulated phosphate fluoride gel(Pascal, USA). After all teeth were maintained in 2% methylene blue solution for 48 hours and cross-sectioned through irradiated surface of dried roots, methylene blue stained area was compared between irradiated side and nonirradiated side. Following results were obtained : 1. Methylene blue stained area was significantly less in the laser irradiated group than control group(p<0.05). 2. There was no significant difference in methylene blue stained area between 0.5W-power and 0.75W-power group(p>0.1) and between 0.75W-power and 1.0W-power group(p>0.1), but there was significant difference between 0.5W-power and 1.0W-power group(p<0.05). 3. There was no significant difference in methylene blue stained area between two groups with and without topical application of 0.12% acidulated phosphate fluoride gel(p>0.1). The results suggest that argon laser irradiation on hypersensitive root may reduce the hypersensitivity by obstruction of dentinal tubules.

  • PDF

Development of Low-Cost and Low-Power Picosatellite Electrical Power Subsystem (저비용/저전력의 초소형위성 전력계의 개발)

  • Park, Je-Hong;Kim, Young-Hyun;Moon, Byoung-Young;Chang, Young-Keun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.7
    • /
    • pp.105-116
    • /
    • 2004
  • The design of pico-/nano-satellites is particularly challenging due to constraints in mass, volume, power, and surface area. An efficient low-cost picosatellite HAUSAT-1 Electrical Power Subsystem (EPS) is developed to supply the power for various loads during the full mission life. This paper addresses design and analysis results of solar arrays, batteries, power conditioning and distribution units. The component selection, manufacturing and test results are presented by considering appropriate development cost and performance. The simulation results of power system are also illustrated, according to operational modes, through energy balance analysis. Finally, the EFS design feasibility is verified by comparing analysis results with functional and environmental test results at the system and component levels, respectively.

Design of a Photovoltaic PCS with Compensation Control of Reactive Power and Unbalance Current in Three-phase systems (3상 시스템의 무효전력, 불평형 전류 보상 기능을 갖는 태양광 전력변환장치 설계)

  • Park, Sang-Min;Kim, Chang-Soon;Le, Dinh Vuong;Park, Minwon;Yu, In-Keun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.3
    • /
    • pp.29-33
    • /
    • 2016
  • Development of the distributed energy resources such as photovoltaic, wind, and fuel cell has increased rapidly due to the rising demand for clean energy utilization. On the other hand, the distribution system became complex and has problems such as degradation of power factor and current unbalance caused by power converters, reactive power and unbalanced loads. To solve these problems, this paper proposes a 3-phase 4-leg type power conditioning system with compensation control algorithm for the reactive power and unbalance current in distribution system using photovoltaic resource. It is simulated in PSCAD/EMTDC and the effectiveness is confirmed.

A Study on Characteristic of Hybrid PCS for Solar Power Generation Considering on a Residential Lithium Battery ESS. (가정용 리튬배터리 ESS를 고려한 태양광 발전 하이브리드 PCS 특성에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-kwon;Choi, Byung-Sang
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.1
    • /
    • pp.35-45
    • /
    • 2022
  • In this paper, we modeled the devices used easily in PV system circuits. In addition, for full operation of the photovoltaic system, a complete operation system for the DC-DC buck-boost converter and the MPPT control system was modeled and simulated to confirm good operation. we were constructed an actual system with the same conditions in the simulation and experimented. The purpose is to confirm the stable power supply through the load leveling by presenting the PCS considering ESS of photovoltaic power generation. we will do study to apply hybrid capacitors that have high energy density to the same size compared to the EDLC to DVR. As a result, we proposed a single-phase 3 kW grid-connected solar power converter.

Calculation of Required Coolant Flow Rate for Photovoltaic-thermal Module Using Standard Meteorological Data and Thermal Analysis (표준기상 데이터와 열해석을 이용한 태양광열 모듈의 필요 냉각수량 산출)

  • Lee, Cheonkyu;Jeong, Hyo Jae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.4
    • /
    • pp.18-22
    • /
    • 2022
  • Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.

An Experimental Study on Performance of Vapor Compression Refrigeration Cycle with Al2O3 nano-particle (Al2O3 나노 입자를 적용한 증기 압축 냉동 사이클의 성능)

  • Kim, Jeongbae;Lee, Kyu-Sun;Lee, Geunan
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.124-129
    • /
    • 2015
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle using inverter scroll compressor with and without $Al_2O_3$ nano particle. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDY to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. The COP of refrigeration cycle with $Al_2O_3$ nano-particle was similar with that of the base cycle without nano-particle between 1000~3000 rpm of the compressor speed. But, This study showed that the COP of the cycle with $Al_2O_3$ over 3000 rpm of the compressor speed was higher than that of the base cycle due to the higher heat transfer rate increased in the evaporator from the higher oil flow rate inside the cycle as well known. Those results can be used the basic and fundamental data to design the air-conditioning cycle using inverter scroll compressor with $Al_2O_3$ nano particle.