An Analysis on the Electricity Demand for Air Conditioning with Non-Linear Models (비선형모형을 이용한 냉방전력 수요행태 분석)

  • Kim, Jongseon
    • Environmental and Resource Economics Review
    • /
    • v.16 no.4
    • /
    • pp.901-922
    • /
    • 2007
  • To see how the electricity demand for air-conditioning responds to weather condition and what kind of weather condition works better in forecasting maximum daily electricity demand, four different regression models, which are linear, exponential, power and S-curve, are adopted. The regression outcome turns out that the electricity demand for air-conditioning is inclined to rely on the exponential model. Another major discovery of this study is that the electricity demand for air-conditioning responds more sensitively to the weather condition year after year along with the higher non-air-conditioning electricity demand. In addition, it has also been found that the discomfort index explains the electricity demand for air-conditioning better than the highest temperature.

  • PDF

Comparative Study on Energy Consumption in Steam-Humidification- and Water-Spray-Humidification-Type Outdoor Air-Conditioning Systems for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 증기가습 및 수분무가습 외기공조시스템의 에너지소비량 비교연구)

  • Kim, Hyung-Tae;Song, Gen-Soo;Kim, Ki-Cheol;Yoo, Kyung-Hoon;Son, Seung-Woo;Shin, Dae-Kun;Park, Dug-Jun;Kwon, Oh-Myung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1249-1255
    • /
    • 2011
  • In modern large-scale semiconductor manufacturing clean rooms, the energy consumed by the outdoor air-conditioning system during heating, humidification, cooling, and dehumidification of the incoming outdoor air represents about 45% of the total air-conditioning load required to maintain a clean-room environment. In particular, the energy required for humidification of the outdoor air in winter is very high. Therefore, evaluation and comparison of the energy consumption in key humidification systems, viz., steam-humidification and water-spray-humidification systems, used in outdoor air-conditioning systems would be useful to reduce the outdoor air-conditioning load in clean rooms. In the present study, an experiment with an outdoor air flow of 1000 $m^3$/h was conducted to compare the air-conditioning process and energy consumption in outdoor air-conditioning systems with electrodeboiler steam humidifiers and air-washer water spray humidification systems. The experimental results showed that the water-spray-humidification-type outdoor air-conditioning system consumed less electrical power than did the steam-humidification-type system and was more energy efficient during winter.

Development of Fuel Conditioning System for 30 kW-class LFG Gasturbine Power Generation (30kW급 LFG 가스터빈 발전용 연료화 정제시스템 개발)

  • Hur, Kwang-Beom;Park, Jung-Keuk;Rhim, Sang-Gyu;Lee, Jung-Bin
    • New & Renewable Energy
    • /
    • v.6 no.1
    • /
    • pp.29-37
    • /
    • 2010
  • Biogas is a carbon neutral energy and consists of mostly methane and carbon dioxide, with smaller amounts of water vapor, and trace amounts of $H_2S$, Siloxane and other impurities. Hydrogen sulfide and Siloxane usually must be removed before the gas can be used for generation of electricity or heat. The goals of this project are to develope the Fuel conditioning system of Land Fill Gas for 30kW-Micro Gas Turbine co-generation system. The fuel conditioning system mainly consists of $H_2S$ removal system, Land Fill Gas compressor, Siloxane removal system and many filtering systems. The fuel requirement of 30kW MGT is at least 32% of $CH_4$, $H_2S$ (<30 ppm), Siloxane (<5ppb) and supply pressure (> 0.6 MPa) from LFG compressor. Main mechnical charateristics of Micro Gas Turbine system by using LFG have the specific performance; 1) high speed turbine speed (96,000 rpm) 2) very clean emmission NOx (<9 ppm) 3) high efficiency of energy conversion rate. This paper focuses on the development of design technology for LFG fuel conditioning system. The study also has the plan to replace the fuel of gas turbine and other distributed power systems. As the increase of Land Fill Gas (LFG), this system help to contribute to spread more New & Renewable Energy and the establishment of Renewable Portfolio Standards (RPS) for Korea.

Performance Analysis of Two-stage Compression Refrigeration System with Internal Heat Exchanger Applied Various Refrigerants (다양한 냉매를 적용한 내부열교환기 부착 2단 압축 냉동시스템의 성능 분석)

  • Yoon, Jung-In;Heo, Seong-Kwan;Je, Jae-Myun;Jeon, Min-Ju;Son, Chang-Hyo;Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.82-88
    • /
    • 2015
  • In this paper, cycle performance analysis of two-stage compression and one-stage expansion refrigeration system applied various refrigerants is presented to offer the basic design data for the operating parameters of the system. The operating parameters considered in this study include degree of superheating and subcooling, compressor efficiency, evaporation temperature, condensing temperature, mass flow rate ration into inter-cooler, effectiveness of internal heat exchanger. The main results were summarized as follows : The COP of two-stage compression and 1-stage expansion refrigeration system increases with the increasing subcooling, mass flow rate ration of inter-cooler, evaporation temperature, but decreases with the increasing condensing temperature and superheating degree. Therefore, subcooling degree, mass flow rate ratio of inter-cooler of two-stage compression and 1-stage expansion using substitute refrigerant have an effect on COP of this system. The COP of alternative refrigerants was higher than the COP of R22 in this study, although the COP of some mixed refrigerants were lower than COP of R22.

Numerical Study for the Optimal Design of Plate Heat Exchanger Using at Seawater Air Conditioning (해수냉난방용 판형 열교환기의 최적설계를 위한 수치적 연구)

  • Kim, Hyeon-Ju;Jung, Young-Kwon;Lee, Ho-Saeng;Yoon, Jung-In;Son, Chang-Hyo
    • Journal of Power System Engineering
    • /
    • v.18 no.4
    • /
    • pp.29-35
    • /
    • 2014
  • Plate heat exchanger are being applied in the field of OTEC (ocean thermal energy conversion) and SWAC (seawater air conditioning) system. This study is to analyze numerically the heat transfer and pressure drop characteristics by using solid works flow simulation in order to offer optimum design data of plate heat exchanger. Plater heat exchanger proposed in this study is four types. The geometric design parameters of plate heat exchanger are a channel space, a flow orientation, a plate array, the flowrate of working fluid and so on. The main results for numerical analysis of plate heat exchangers are summarized as follows. Heat transfer performance for the channel space of 2.4 mm shows the highest value compared to other spaces. And, the Type 4 plate heat exchanger in Table 2 is the highest performance. From the pressure drop characteristics of plate heat exchanger, the channel space of 3.2 mm shows the lowest value. And Type 1 plate heat exchanger in Table 2 is the lowest pressure drop.

Development of Power Conditioning System for Photovoltaic Power Generation Systems (태양광발전용 3kW급 PCS개발)

  • Min, Byoung-Gwon;Ryu, Seung-Pyo;Jeon, Se-Bong;Lee, Bong-Woo;Kim, Nam-Hae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.123-126
    • /
    • 2005
  • Recently, because of the depletion of fossil fuels and the environmental pollution by using fossil fuels and harmfulness of atomic power plants. the interests concerning new and renewable energy resources are rising increasingly. And of all new and renewable energy sources the PV generation systems are recognized as the most useful and desirable renewable energy source in allowance for installation conditions. In this development, the 3kWp photovoltaic power generation system is realized to verify the performance of the 3kWp PCS developed by Hyundai Heavy Industries Co. (HHI). The photovoltaic array used in this system is composed of 60 modules of 50Wp capacity. The developed system is tested as procedures and items of test regulation recognized by governmen and the experimental results show the excellent electrical characteristics. Now, the 3kWp PCS developed is installed in the PV model house built in HHI plant and is being tested for practical use commercialization.

  • PDF

Characteristics of Energy Consumption in an Office Building located in Seoul (사무소건물의 용도 및 측정기간에 따른 에너지 소비 특성)

  • Park Byung-Yoon;Chung Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.1
    • /
    • pp.82-87
    • /
    • 2005
  • The purpose of this study is to suggest the characteristics and actual state of energy consumption by the analysis of energy consumption data in an office building. This study examines and analyzes daily and monthly energy consumption of an office building located in Seoul, Korea regarding type of load and business classification within a building. The results are as follows. 1) Energy consumption of office building for each type of load show similar consumption patterns, regardless of seasons such as cooling period and heating period. 2) Out of all annual energy consumption, consumption for lighting took about $43\;\%,$ general electric Power about $23\;\%,$ emergency power $25\;\%,$ computer center $5\;\%$ and cooling power $4\;\%,$ showing that the consumption for lighting was highest, and the percentage of energy consumption for cooling power for operation of cooling facilities took the lowest percentage. 3) Annual gas consumption used for heating and hot water supply were $38,\;36\;\%$ for officetel and office respectively, and $26\;\%$ for arcade. 4) Electricity consumptions used for cooling power for each use of building, office and officetel recorded in July and August of cooling seasons. Even though it shows different patterns for each month, energy consumption showed unique pattern throughout the cooling seasons.

Performance of Thermoelectric Power Generator with Various Thermal Conditions (열전소자의 열적조건 변화에 따른 발전 특성)

  • Han, Hun-Sik;Kim, Myung-Kee;Um, Suk-Kee;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.165-170
    • /
    • 2010
  • Experiments have been performed to investigate the key parameters determining the performance of thermoelectric power generation. The experimental results obtained show that the power output significantly increases with the temperature difference between cold and hot sides of thermoelectric generator. However, the effect of the hot side temperature under the identical temperature difference on the overall performance of a thermoelectric generator is meager. The conversion efficiency defined as the ratio of the power generated to the heat absorbed at the hot side increases with the temperature difference. The behavior of the thermoelectric generator is shown to be consistent with the theoretical analysis. The optimum current giving the maximum conversion efficiency and the maximum conversion efficiency are linearly increased with the temperature difference.