• Title/Summary/Keyword: power conditioning

Search Result 1,094, Processing Time 0.025 seconds

Using the Loss parameter calculation method for the CPV system simulation (손실파라미터계산방법을 이용한 집광형태양광발전시스템 시뮬레이션)

  • Lee, Kang-Yeon;Jeong, Byeong-Ho;Kim, Ji-won
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.17-26
    • /
    • 2017
  • CPV system is composed with CPV cells, modules, PCS(power conditioning system), solar tracker, system installation and balance of systems(BOS). Mention about modelling method which is applied for CPV system simulation and evaluation system analysis. This paper focuses on CPV system modeling and optimal design of the electric energy production analysis through the development of proposed optimal CPV system simulation. Calculated simulation results of the generalized CPV system in regard to loss parameter calculation method can make out optimal configuration of CPV system with high reliability and stability. The loss parameter calculation method establish a mathematical modeling for the purposed of simulation and utilization various data for economical analysis of the CPV system design.

Vibration Intensity Method to Detect Vibration Source of Rotary Compressor (로터리 컴프레서 진동원 검출을 위한 인텐시티 기법)

  • Kim, Heui-Cheol;Lee, Dong-Yeon;Yi, Hwa-Cho;Shim, Jae-Sool
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.8
    • /
    • pp.3398-3405
    • /
    • 2011
  • Vibration intensity (VI) method is used to reduce sound source generated from air-conditioning rotary compressor. Generally VI method is a good tool to find a sound source through vibration power flow. In this paper, the vibrations are measured by using the 3 uni-axial accelerometer from both the shells of the normal compressor and the fault compressor. The VI method successfully found out the sound source position on the surface of the compressor. In addition, the main noise (3kHz ~ 6.3kHz) was deminished by applying the newly designed compressor inner part which is related to the orginal noise source.

A Return Bender Automatic Brazing Welding System for Heat Exchangers (열교환기용 리턴 밴더 자동 브레이징 용접 시스템)

  • Lee, Yong-Joong;Kang, Jin-Kap;Lee, Hyung-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.5 no.2
    • /
    • pp.49-55
    • /
    • 2006
  • In the consideration of the problem occurred by certain return bender brazing welding works that depend only on handworks, the automatization of the whole production line is impossible due to the high dependency of skillful workers. In addition, it is difficult to establish a standardization due to the various heat exchanger model and irregular amount of orders, and the fault reduction is also impossible due to the severe difference in brazing conditions. It is necessary to develop a method, which quantitively analyzes the problem existed in this manual brazing welding of return benders and technically solves that problem, and to lead the improvement of the productivity and cost reduction in order to increase the business competitive power. Then, this will contribute the technical development of automatic welding for Korea's heat exchanger businesses. Thus, this study develops an automatic technology, which automatically controls the flame strength using digital control methods, for various models and produces a sample model. It is possible to increase the productivity and produce uniformed and qualified products by solving the problem existed in manual processes using the developed automatic return bender brazing system. In addition, the brazing condition can be automatically controlled according to the model and line speed, and such an economical operation can reduce the production cost. The developed system is expected to future applications not only heat exchangers in the field of refrigeration and air conditioning, but also other various industrial fields that apply heat exchangers, such as car and boiler industries.

  • PDF

Thermal Analysis on the LNG Storage Tank of LNG Bunkering System Applied with Double Shield Insulation Method (LNG 벙커링용 이중 단열적용 LNG 저장탱크 열해석)

  • Jung, Il-Young;Kim, Nam-Guk;Yun, Sang-Kook
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.1-6
    • /
    • 2018
  • An LNG bunkering system stores LNG in a horizontal IMO's C-Type tank insulated with perlite powder, and $10^{-2}$ Torr vacuum in the annular space between the double walls. Current storage tanks have high heat leakage, evaporating over 2.0% daily. A more efficiently insulated storage tank reducing the evaporation rate is required to develope. This research carried out thermal analysis on a new effective insulation method, i.e. double shield insulation system, that separates high super vacuum in the annular space between two tanks with a perlite vacuum in the back side of outer tank. This highly efficient insulation system obtained an evaporation rate of 0.16% per day under a $10^{-4}$ Torr vacuum. Even if the space loses its vacuum, the new insulation system showed a lower evaporation rate of 5.23% than the present perlite system of 4.9%.

The Performance Characteristics of Heat Pump Using the Refrigerant Subcooling (냉매 과냉각을 이용한 열펌프 시스템의 성능 특성)

  • Roh, Geon-Sang;Son, Chan-Ghyo
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.4
    • /
    • pp.413-421
    • /
    • 2007
  • In this paper, the performance characteristics of heat pump system using a new refrigerant subcooling system designed for the study, are introduced. The new heat pump system have the ice storage tank at the outlet of condenser. The experimental apparatus is a well-instrumented water/water heat pump which consisted of working fluid loop, coolant loop, and ice storage tank. The experiment parameters of subcooling ranged as the evaporating temperature from $-5^{\circ}C$ to $8^{\circ}C$, the condensing temperature from $30^{\circ}C$ to $35^{\circ}C$. The test of the ice storage was carried out at evaporating temperature of $-10^{\circ}C$ and the ice storage mode is Ice-On-Coil type. The working fluid was R-22 and the storage materials were city-water. The test results obtained were as follows; The refrigerant mass flow rate and compressor shaft power were unchanged by the degrees of subcooling, that is, they were independent of degrees of subcooling. The cooling capacity of the new heat pump system increase as the evaporating temperature and subcooling degrees increase and is higher by $25{\sim}30%$, compared to the normal heat pump system. The COP of the new heat pump system increases as the degrees of subcooling and evaporating temperature increase and is higher by 28% than that of the normal heat pump system.

An Experimental Study on Performance of Energy Recovery Ventilation System (폐열회수 환기시스템의 성능에 관한 실험적 연구)

  • Kim, Young-Soo;Choi, Kwan-Soo;Kim, Il-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.445-450
    • /
    • 2012
  • At the limited space, the air conditioning may have difficult to control temperature or humidity for home use. Nowdays, the people reponse to temperature or humidity sensitively. This becomes the Indoor Air Quality (IAQ) is an important factor for comfortably. Heat recovery ventilator (HRV) is used for the solution of inconsistency between IAQ and power-saving. Also, the thermoelectric element is applied to HRV and compared with temperature efficiency and verifying the capacity of the system. To improve the temperature efficiency a single motor and thermoelectric element with the conductive guide vane is experimented. The results shows that it can save 23 W by using the single motor. The developed system of 250 CMH capacities with the thermoelectric element reveals the temperature efficiency improvement of 4.01% in cooling period and 2.98% in heating period compared to the conventional system.

Block Smart Rack Technology Development for Increased Efficiency (효율성 증가를 위한 블록 단위 스마트 랙 기술 개발)

  • Tae, Hyo-Sik;Park, Koo-Rack
    • Journal of the Korea Society of Computer and Information
    • /
    • v.20 no.4
    • /
    • pp.11-16
    • /
    • 2015
  • Data center, not only the development of globally of cloud-based IT solutions, As the big data, education, use of development electronic equipment of communication means is increased, Demand of domestic and international data center has increased steadily. Due to the increase of data center demand, heat generation of server rack due to the development of IT equipment is also increasing continuously. Calculating heat value of the data center, because more than 99% of the power usage of IT server is converted into heat, the calorific value as the size and capacity of the server is larger will increase. In this paper, to center the cooling system of air-cooled, and research and development of air conditioning systems for energy reduction of data center, through performance analysis and simulation, it has been analyzed that there is energy savings.

Study on Characteristics of Heat Transfer and Flow in Plate Heat Exchanger (판형 열교환기의 열전달과 유동특성에 대한 연구)

  • Jin, Zhen-Hua;Lee, Kwang-Sung;Ji, Myoung-Kuk;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1476-1483
    • /
    • 2009
  • In present work, experiments conducted to investigate the heat transfer characteristics and relationship between operating parameters and production of fresh water as output of the system. Plate Heat Exchanger (PHE) applied in vacuum evaporator for product fresh water that system intended to efficiently use low grade heat. PHE have become popular in chemical, power, food and refrigeration industries due to the efficient heat transfer performance, extremely compact design and flexibility of extend or modify to suit changed duty. The heat transfer part contains corrugated plates with 60 degree of chevron angle which verified by many researchers and commonly apply. Fresh water can be produced from saline water under near vacuum pressure by operating ejector. Consequently, evaporating temperature stay around $51-57^{\circ}C$ so it is possible to use any low grade heat source or renewable source. The maximum fresh water produced by freshwater generator with plat heat exchanger applied in the study was designed as 1.0 Ton/day.

  • PDF

The Fast Interlock Controller for High Power Pulse Modulator at PAL-XFEL (고전압 펄스 모듈레이터의 고속 인터록 제어)

  • Kim, S.H.;Park, S.S.;Kwon, S.J.;Lee, H.S.;Kang, H.S.;Ko, I.S.;Kim, D.S.;Seo, M.H.;Lee, S.Y.;Moon, Y.J.
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.818-819
    • /
    • 2015
  • PAL-XFEL 장치에 사용 할 고전압 펄스 모듈레이터 출력파워는 수 ${\mu}s$ 범위의 짧은 고전압(400 kV), 대전류(500 A) 펄스를 요구한다. 이러한 펄스파워를 얻기 위해서 PFN(Pulse Forming Network)에 에너지를 축적하고, 플라즈마 스위치인 싸이라트론을 통하여 에너지를 신속하게 클라이스트론 쪽으로 전달한다. 클라이스트론은 모듈레이터에서 공급하는 펄스 전원을 이용하여 RF를 증폭하는 대출력 고주파 증폭장치이다. 고전압 펄스 모듈레이터 제어기는 고속펄스 신호처리 모듈(Fast Pulse Signal Conditioning Module), PLC(Programmable Logic Controller)로 구성되어 있다. 고전압 펄스 모듈레이터에 사용하는 대용량 싸이라트론은 고전력을 스위칭 할 때 발생하는 스위칭 노이즈는 매우 크다. 이러한 노이즈는 모듈레이터의 출력 시그널인 빔 전압, 빔 전류, EOLC(End of Line Clipper) 전류, DC high voltage에 섞여 있으면서 신호 왜곡 및 제어장치의 고장을 유발시킨다. 이처럼 노이즈가 많이 포함되어 있는 아닐로그 신호를 깨끗한 신호(a clean signal)로 바꾸어주는 노이즈 필터링 장치인 고속펄스 신호처리 모듈을 제작하여 실험한 결과를 알아보고 모듈레이터 인터록 시스템인 PLC에서 Dynamic Interlock의 응답시간을 빠르게 하기위한 회로 수정에 대한 결과에 관하여 기술하고자 한다.

  • PDF

Development of control and monitoring board for building energy saving valve (빌딩 에너지 절감 밸브용 제어 및 감시 보드 개발)

  • Oh, Jin-Seok;Kang, Young-Min;Jang, Jae-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.895-902
    • /
    • 2018
  • Energy consumption in buildings is close to 40% of the total national energy consumption in developed countries such as US and Japan, and Korea accounts for 24% of total energy consumption. In buildings, HVAC can't freely control the cooling flow rate according to the required calorie, so energy is not used efficiently. Therefore, by using the energy saving valve, the flow rate can be controlled by the required amount of heat and the energy can be saved. In this paper, we define basic conditions and develop control and monitoring boards for building energy saving valves based on PIC processor with low power and high cost-effectiveness. The designed board displays and transmits in real time information about two temperature values, flow values and calculated calories for temperature difference measurement. The developed board will be useful for real - time monitoring of the state of the valve in the future and development of the valve for the offshore.