SINGLE-PHASE ACTIVE RECTIFIER WITH HIGH POWER FACTOR CAPABILITY FOR INVERTER AIR-CONDITIONER

  • Jung, Yong-Chae;Kwon, Kyung-Ahn
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.677-682
    • /
    • 1998
  • A Single-phase Active Rectifier (SAR) [4-6] with high power factor capability is adopted to satisfy the international harmonic current standards such as IEC 1000-3-2. To minimize the input current distortion and to apply the control IC, such as FA5331, UC3854, ML4821 and so forth, the new adequate sensing circuits of the input voltage and current are proposed. There are tow methods applicable the SAR to inverter air-conditioner from the viewpoint of both efficiency and cost. The selecting methods of the passive components are presented for the two approaches. Using the determined components, the loss analyses are carried out. The prototype SAR circuits of these two approaches with 3kW power consumption are built and the operation and performance of the circuits with power factor correction capability are verified through the experimental results.

  • PDF

A New Three Winding Coupled Inductor-Assisted High Frequency Boost Chopper Type DC-DC Power Converter with a High Voltage Conversion Ratio

  • Ahmed Tarek;Nagai Shinichiro;Hiraki Eiji;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • 제5권2호
    • /
    • pp.99-103
    • /
    • 2005
  • In this paper, a novel circuit topology of a three-winding coupling inductor-assisting a high-frequency PWM boost chopper type DC-DC power converter with a high boost voltage conversion ratio and low switch voltage stress is proposed for the new energy interfaced DC power conditioner in solar photovoltaic and fuel cell generation systems. The operating principle in a steady state is described by using its equivalent circuits under the practical condition of energy processing of a lossless capacitive snubber. The newly-proposed power MOSFET boost chopper type DC-DC power converter with the three-winding coupled inductor type transformer and a single lossless capacitor snubber is built and tested for an output power of 500W. Utilizing the lower voltage and internal resistance power MOSFET switch in the proposed PWM boost chopper type DC-DC power converter can reduce the conduction losses of the active power switch compared to the conventional model. Therefore, the total actual power conversion efficiency under a condition of the nominal rated output power is estimated to be 81.1 %, which is 3.7% higher than the conventional PWM boost chopper DC power conversion circuit topology.

교류철도급전계통에 전력품질보상장치 적용에 관한 연구 (A Study on the Application of UPQC in AC Railway System)

  • 최준호
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.220-229
    • /
    • 2004
  • 전기 철도계통은 기존 전력계통과 달리 단상, 대용량 부하로 필연적으로 전압강하, 전압불평형 및 고조파 왜곡 등의 전력품질의 문제가 발생한다. 최근 철도계통의 전력품질문제는 철도차량 및 시스템의 제어 및 안전 때문에 중요한 화두가 되고 있다. 이는 또한 기존 전력계통의 전력품질에도 영향을 미친다 본 논문에서는 전기철도 급전시스템에 발생하는 전력품질문제의 보상에 관한 연구를 수행하고자 한다. 이를 위해 국내 교류전기철도 표준 급전방식인 AT(Auto Transformer)급전시스템, 철도급전변압기인 스콧트 변압기(Scott Transformer), AT변압기, 철도선로 및 철도 차량부하를 모델링 하였다. 과도응답은 전자기과도해석 프로그램인 PSCAD/EMTDC를 사용하여 해석 하였다. 또한 전력품질을 보상하기위한 방안으로 급전선-전차선에 설치되는 전력품질보상기(Unified Power Quality Conditioner : UPQC)를 제안하였고 이의 성능 및 유효성을 시뮬레이션을 통하여 확인하였다.

다구찌 방법에 의한 PAC 실내기 유로의 최적설계 (Optimum Design of an Indoor Package Air-Conditioner's Flow Path by Taguchi Method)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.32-37
    • /
    • 2014
  • In this study, the optimum design process of an indoor package air-conditioner (PAC) was implemented by Taguchi method. The goal of this study is to obtain the best set condition of each control factor composing of an indoor PAC. The number of revolution of a double inlet sirocco fan installed in an indoor PAC was measured by the orthogonal array of $L_{18}(2^3{\times}3^4)$ and analysed by using the-smaller- the-better characteristic among the static characteristic analyses. As a result, the optimum condition of an indoor PAC was found as a set of when the cost of production, assembling and working conditions were considered. Moreover, the number of revolution of a double-inlet sirocco fan used for an optimum condition was reduced about 8.5% more than that of a standard condition for the target flowrate of $18.5m^3/min$.

A Simple Power Management Scheme with Enhanced Stability for a Solar PV/Wind/Fuel Cell Fed Standalone Hybrid Power Supply using Embedded and Neural Network Controller

  • Thangavel, S.;Saravanan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1454-1470
    • /
    • 2014
  • This paper propose a new power conditioner topology with intelligent power management controller that integrates multiple renewable energy sources such as solar energy, wind energy and fuel cell energy with battery backup to make best use of their operating characteristics and obtain better reliability than that could be obtained by single renewable energy based power supply. The proposed embedded controller is programmed for maintaining a constant voltage at PCC, maximum power point tracking for solar PV panel and WTG and power flow control by regulating the reference currents of the controller on instantaneous basis based on the power delivered by the sources and load demand. Instantaneous variation in reference currents of the controller enhances the controller response as it accommodates the effect of continuously varying solar insolation and wind speed in the power management. The power conditioner uses a battery bank with embedded controller based online SOC estimation and battery charging system to suitably sink or source the input power based on the load demand. The simulation results of the proposed power management system for a standalone solar/WTG/fuel cell fed hybrid power supply with real time solar radiation and wind velocity data collected from solar centre, KEC for a sporadically varying load demand is presented in this paper and the results are encouraging in reliability and stability perspective.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

인버터 에어컨을 위한 고역률 단상능동정류기 (High Power Factor Single-Phase Active Rectifier for Inverter Air-Conditioner)

  • 정용채;권경안
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.144-151
    • /
    • 1999
  • 본 논문에서는 IEC 61000-3-2와 같은 고조파 전류 국제규제에 만족하기 위해서 인버터 에어컨을 위한 고역률 단상능동정류가(SAR) [4-6]를 적용하였다. 입력전류의 왜곡을 최소화하고 FA5331, UC3854, ML4821 등과 같은 제어IC를 적용하기 위해서 입력전압 및 전류에 대한 새롭고 적절한 검출회로를 제안하였다. 효율 및 가격의 관점에서 SAR를 인버터 에어컨에 적용하기 위한 두가지 방법이 있다. 이런 두가지 방식에 대해서 수동소자의 선정방법을 제시하였다. 결정된 소자들을 사용하여 SAR 효율의 증가 여부를 확인하기 위해서 손실분석을 행하였다. 3kW급의 이러한 두가지 방식에 대한 프로트형 SAR회로를 제작하고 실험결과를 통해서 역률제어능력을 갖는 회로의 동작과 성능을 확인하였다.

  • PDF

Control of a Single Phase Unified Power Quality Conditioner-Distributed Generation Based Input Output feedback Linearization

  • Mokhtarpour, A.;Shayanfar, H.A.;Bathaee, M.;Banaei, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1352-1364
    • /
    • 2013
  • This paper describes a novel structure for single phase Unified Power Quality Conditioner-Distributed Generation (UPQC-DG) with direct grid connected DC-AC converter for low DC output DG systems which can be used not only for compensation of power quality problems but also for supplying of load power partly. This converter has been composed of one full-bridge inverter, one three winding high frequency transformer with galvanic isolation and two cycloconverters. Proper control based on Input Output feedback Linearization is used to tracking the reference signals. The simulation and experimental results are presented to confirm the validity of the proposed approach.

수력발전소 자동제어설비 시험용 신호변환장치 개발에 관한 연구 (A Study on Development of Signal Conditioner for Test of Automatic Control Equipments in Hydro Power Plant)

  • 변두균;장문성;김주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.169-171
    • /
    • 1995
  • Automatic control equipment in hydro power plant, such as turbine governor or automatic voltage regulator have to act promptly against for variation of power system, so it is necessary to check and test continuously. During last five years, the performance test of automatic control equipment was performed about 20 units of hydro turbine generator. In this process, because it has complex connection and before calibration, signal conditioner was developed as an auxiliary equipment for performance test. It includes function of signal amplifier, transducer, and meters. As a result of use this equipment for electric governor test at soyang-gang hydro power plant, it was possible to find output data equal to old one.

  • PDF

원자력 발전소에 사용되는 항온항습기의 안전관련 기기검증을 통한 최적 모델 개발 (Development of An Optimum Model Using Safety-Related Equipment Qualification for the Air Conditioner in the Nuclear Power Plant)

  • 서욱환;이영섭
    • 한국안전학회지
    • /
    • 제21권1호
    • /
    • pp.1-5
    • /
    • 2006
  • The damage of important equipments for the nuclear power plant by the earthquake brings the loss of human lives and economic losses. Therefore safety-related equipment of nuclear power plant must be proved that function must be designed and structural integrity so that it can be maintained also from accident condition of various kinds. In this study, the computer room air conditioner to be delivered at the nuclear power plant applied to this qualification, try to develop an optimum model. This model ended up with good results which were under suitably allowable conditions about structurally safe earthquake.