• 제목/요약/키워드: power cable insulation

검색결과 244건 처리시간 0.026초

154kV 케이블 콘넥터의 설계와 특성 평가 연구 (Performance and Design of Cable Termination for 154kV Class)

  • 조한구;김광용;이철호;이용순
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

22.9kV 배전선로 절연전선의 부식 검출 시스템 개발에 대한 연구 (A Study on the Development of Corrosion Detecting System for 22.9 kV Distribution Power Line Insulation Cable)

  • 김용준;오용철;이건영
    • 전기학회논문지
    • /
    • 제60권7호
    • /
    • pp.1410-1416
    • /
    • 2011
  • A corrosion detecting system for 22.9 kV distribution power line insulation cable, which can travel autonomously along the live line, is proposed. Eddy current test method is employed to detect the corrosion, and the system developed here is capable of detecting internal corrosion of a ACSR-OC. Somewhat details of the electrical and mechanical mechanism of the system and traveling algorithm are introduced. Experimental results applied to the sample cables having artificial corrosion and the operating distribution lines are provided. From the result, we confirmed that the system is useful for detecting internal corrosion of a ACSR, and is expected to be a new non-destructive testing equipment in the area of diagnosis for the distribution power line.

화력 발전소 고전압 케이블 접속재의 On-Line 직류 누설 전류 시스템 개발과 진단 Factor에 관한 연구 (A Study on Development and Diagnosis Factors of On-Line DC Leakage Current System for Junctions of High-Voltage Cables in Operation at Thermoelectric Power Station)

  • 박성희;엄기홍
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권6호
    • /
    • pp.187-193
    • /
    • 2018
  • 국내에서의 전력에 대한 수요는 점진적으로 증가하고 있는 추세이다. 수요에 대응하기 위한 발전소는 기능이 다양해지고 효율이 점차 커져야 한다. 발전소 내의 전력 기기에서 사고가 발생하면 막대한 경제적 손실 및 장애를 초래하게 된다. 사고 발생의 원인 중의 하나로서 절연 성능이 저하 된 케이블이 있다. 케이블 사고를 미연에 방지하기 위하여 절연의 상태를 감시하고 확인하여야 한다. 케이블 사고는 연결 부위인 접속에서 발생하는 사고가 대부분을 차지한다. 본 연구와 관련하여 우리는 접속부 상태를 판별하기 위한 장비를 개발하였고, 한국서부발전(주)의 현장에 설치하여 운용 중이다. 본 논문에서는 현장에서 설치 운용 중인 장비에 대한 설명과 더불어 설치 운용된 결과를 통해 케이블의 수명을 예측할 수 있는 고전압 케이블 접속재의 안정적 사용을 위한 온라인 감시진단기법 중에서 사고가 가장 빈번하게 발생하는 접속부에 대해 안정적인 사용을 위한 진단의 정확성과 신뢰성을 향상시키기 위한 연구를 하였다. 이 논문에서 하드웨어 구성을 위주로 우리가 개발한 장비를 소개한다.

22kV 전력케이블의 열화 판정에 관한 연구 (A Study on the Remain Life with Aging in 22kV CV cable)

  • 이관우;목영수;김보경;박복기;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.19-21
    • /
    • 2003
  • In this paper, we studied on life-decision of underground cable of live-lines state. As all equipments have been wear, underground cables decided design-life on the whole 30 years because underground cable have been occurred aging as time goes. CV cable has been become about 30 years after installation in the South Korea, is come to a important point of time with estimation about life. Study target cable is 22 kV CV cables in this point of view and installation cable is about 10 years before and behind. Measurement method used dc leakage method of live-lines state that applied voltage of 50V in neutral point and data is analyzing result that is measured during 5 years. In this result, insulation resistance could confirm that change according to season and cause is effect of humidity, seasons and load current. Also, according as data is gone aging, insulation resistance by Weibull distribution could confirm functionally its decrease. As a result, the aging speed of cable that water tree is gone could confirm fastness very. Numerical analysis result, cable that water tree is not gone could confirm that life of cable that has passed 10 years remains about $10{\sim}20$ years.

  • PDF

초전도 전력케이블의 열 등가 회로에 관한 연구 (A Study on the Equivalent Thermal Circuit for HTS Power Cable)

  • 이수길;이흥재
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권1호
    • /
    • pp.61-65
    • /
    • 2010
  • To develop the thermal analysis method for the thermal behavior of HTS power cable system, cooled with sub-cooled liquid nitrogen, new thermo dynamic model for HTS cable system is introduced. The introduced thermal model is mainly modified from the thermal circuit following to IEC60287 for underground power cable systems such as XLPE or paper wrapped insulation cables. The thermal circuits for HTS cables are similar to the forced cooled underground cable system but the major thermal parameters and the configuration is apparently different to the normal cable systems so there has been no proposals in this field of analysing method. In this paper, 154kV HTS cable system has been introduced as an aspects of thermal models and a thermal circuit is proposed for the fundamentals on the dynamic rating systems for the HTS cable system. By using the thermal circuit developed in this paper, the optimal controls on the sub-cooling system's capacity become possible and it is expected to make the efficiency of HTS cable higher than conventional static controls.

사우디아라비아 380kV XLPE Cable의 신뢰성 확보를 위한 온라인 부분방전 모니터링 시스템 구축 (Construction of On-line Partial Discharge Monitoring System for 380kV XLPE Cable in Saudi Arabia)

  • 서인진;이전선;김한중;김종철;김정윤;이현선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.95-96
    • /
    • 2008
  • We constructed an on-line PD monitoring system for the 380kV U/G Cable project at the Riyad 9012 substation in Saudi-arabia. The system will be monitoring the termination of the two 380kV XLPE Cables to prevent unexpected failure of the cable insulation. The system had been tested in the laboratory and on-site for detection of various PD signals and reliability of operation. The system distinguish the existence and nonexistence of the partial discharge and then judge the source of partial discharge using automatic PD pattern recognition software.

  • PDF

Mini-model 초전도 케이블의 유전손실 특성 (The Dielectric loss Properties of Mini-model Superconducting Cable)

  • 김영석;곽동순;한철수;김해종;김동욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제16권10호
    • /
    • pp.946-951
    • /
    • 2003
  • A high-Tc superconducting cable(HTS cable) is expected as an underground power line supplying the electrical power the densely populated city in future. The electrical insulation is very important for develop HTS cable system because it is operated a high voltage and in cryogenic temperature. We manufactured a mini-model cable and measured a tan$\delta$ of cable using schering bridge. The tan$\delta$ of PPLP was lower than that of Tyvek and Kraft at a given temperature, the tan$\delta$ of PPLP was 1.16${\times}$10-3. According to the increase of electric stress the tan$\delta$ increased because partial discharge occurred inside butt gap of mini-model cable. However, the tan$\delta$ decreased by increase of liquid nitrogen pressure. This reason is thought by decrease of part discharge between butt gap by increase of liquid nitrogen pressure.

고압케이블의 절연열화 특성 (Characteristics of Insulation Aging in High Voltage Cables)

  • 김경열
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.88-88
    • /
    • 2010
  • High Voltage cross-linked polyethylene (XLPE) cables are widely used in a thermal power plant. These cables had been in service for 26 years. The insulation condition of six 6 kV XLPE cables was estimated by insulation diagnostic analyzer (IDA) with voltage amplifier. IDA was measured dissipation factor and capacitance of the whole cable as a function of frequency and voltage. This system measures in the frequency range from 0.1 to 10 Hz at each voltage level. Six XLPE cables are judged good condition, but three cables are analyzed at an aged condition.

  • PDF

A Study on Lightning Surges in Underground Distribution Systems

  • Jung Chae-Kyun;Kim Sang-Kuk;Lee Jong-Beom
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권2호
    • /
    • pp.171-176
    • /
    • 2005
  • The effects of surge arresters for the protection of transmission systems against direct lightning strokes have already been reviewed by many researchers. However, their studies have not encompassed underground cable systems. Therefore, in this paper we investigate the 22.9kV combined distribution systems that have arresters and ground wires. In addition, we analyze the overvoltages on underground distribution cable sections when direct lightning strokes contact the overhead ground wire using EMTP. Finally, we discuss the effect of lightning strokes according to the change of cable length and installation of arresters. This study provides insulation coordination methods for reasonable system design in 22.9kV underground distribution cable systems.

CV케이블의 부분방전 신호를 통한 열화과정의 정량적 진단 (Normalization Diagnosis of Aging Process on Partial Discharge Signals of CV Cable)

  • 소순열;임장섭;김진사;이준웅;김태성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.451-455
    • /
    • 1997
  • The partial discharge has been blown as the chief breakdown of power equipments. The analysis and the recognition is much difficult because the partial discharge signal is very small and has complex aging pattern. Recently, insulation aging diagnosis based on pattern of phase(Ф), partial discharge magnitude(q), number(n) has been very important. Owing to depreciate the reappearance of aging progress at the electrical tree pattern and to be difficult to analyze visually, the study on partial discharge pattern is suggested to normalizing analysis method of partial discharge signals. This parer is purposed on prediction of life-time measurement of cv-cable, on decision of risk degree with normalization and real-time measurement of partial discharge signals for aging diagnosis of cv-cable. As normalizing the aging signals of electrical tree in cv-cable, it is able to confirm risk degree of insulation material with the distribution of Ф-q-n and recognize the process of aging pattern using neural network.

  • PDF