• Title/Summary/Keyword: power analyzer

Search Result 484, Processing Time 0.028 seconds

Establishment of the Electromagnetic Shielding Effectiveness Measurement System (전자파차폐효과 측정시스템의 구현)

  • 정연춘;강태원;정낙삼
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.4 no.3
    • /
    • pp.45-53
    • /
    • 1993
  • The shielding effectiveness of materials is determined by measuring the ratio of the incident electromagnetic power to that which passes through the material under test. The measurement system is constructed using several test fixtures, tracking generator, spectrum analyzer, step attenuator, RF switches, and amplifiers, etc.. The automation of measurements is completed using a personal computer. Especially, incident power, reflected power, and transmitted power are measured with only one spectrum analyzer using a dual directional coupler and RF switches. Therefore the system is to be used in design of shielding materials, as well as shielding effectiveness measurements. This system has dynamic range of more than 120 dB in the frequency range of 10 MHz to 1 GHz, and it can be used to measure shielding effectiveness of composite materials.

  • PDF

Development of Portable Colorimeter and Size Analyzer by Using Smartphone (스마트폰을 이용한 휴대용 색차계와 입도계 개발)

  • Yoo, Sanggyu;Park, Hyunmin;Kim, Hyungu;Kim, Sayeom;Song, Simon
    • Journal of the Korean Society of Visualization
    • /
    • v.17 no.3
    • /
    • pp.19-23
    • /
    • 2019
  • The purpose of this research is to develop a facile measurement system for colorimetric analysis for zinc powder and size analyzer for zeolite particles in order to reduce the process time for their characteristic analysis. We present facile smartphone-based analysis methods to measure and estimate the size of zinc power by using colorimeteric method and the size of zeolite particles by using ImageJ program which is an open-source program. The results show a possibility of our methods to replace the previous professional analysis processes with them.

On-line partial discharge measurement techniques of hydro-generator windings (수력 발전기 권선에서의 운전중 부분방전 측정기법)

  • 황동하;김진봉;김용주;박명수;김택수
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

Effect of Whey Brew Cultured by Lactobacillus helveticus ATCC 55163 and Propionibacterium acidipropionici 5020 on Rheological Properties of Flour Dough (Lactobacillus helveticus ATCC 55163과 Propionibacterium acidipropionici 5020로 배양한 유청발효물이 반죽의 레올로지에 미치는 영향)

  • Yun, Mi-Suk;Chae, Soo-Kyu;Lee, Jeong-Hoon
    • Culinary science and hospitality research
    • /
    • v.15 no.1
    • /
    • pp.149-156
    • /
    • 2009
  • This study was carried out to evaluate the effect of whey brew cultured by the mixed Lactobacillus helveticus ATCC 55163 and Propionibacterium acidipropionici 5020 on the rheological properties of flour dough. 10 and 15% of whey brews were added to the dough based on flour. Farinograph, alveograph, Rapid Visco Analyzer, and fermenting power of dough were analyzed. In the farinograph analysis, as the amount of whey brews increased on dough samples, water absorption, dough development time, stability, and breakdown increased. In the alveograph analysis, as the amount of whey brews increased on dough samples, P and W value increased while L and G value decreased. In the Rapid Visco Analyzer analysis, as the amount of whey brews increased on dough samples, initial pasting temperature and peak viscosity increased while final viscosity and setback decreased. Decrease of setback showed the delay of starch retrogradation. As the amount of whey brews increased on dough samples, fermenting power of dough got reduced.

  • PDF

Development of a Portable Vibration Analyzer for Precision Diagnosis of Plant's Rotating Equipment (발전소 회전기기 정밀진단을 위한 휴대용 진동분석기 개발)

  • Noh, Hyungho;Y, Hoseon
    • Plant Journal
    • /
    • v.17 no.4
    • /
    • pp.53-60
    • /
    • 2021
  • The purpose of this study was to develop a portable vibration analyzer that is effective for acquiring and analyzing vibration data of rotating equipment of a power plant and a domestic vibration monitoring system manufacturer Nada Co., Ltd. The hardware of the developed portable vibration analyzer minimizes measurement errors by calibrating the measured values obtained through measurement uncertainty for calibration of the measuring devices in the system, and is composed of a signal processing device with high resolution through high speed data processing. The software structure implements a variety of vibration plots to execute a detailed analysis program, and applies algorithms to measure and remove noise caused by disturbances while operating a rotating machine. The developed product contributed greatly to increase the user's mobility and performance, as well as to reduce the purchase cost due to localization.

Development of the Soil Thermal Property and Temperature Measurement System for the Real-time Ampacity Estimation of Underground Power Cables (실시간 지중 전력케이블 용량 평가를 위한 토양 열 특성 및 온도 측정 시스템 개발)

  • Jeong, Seong-Hwan;Kim, Dae-Kyeong;Choi, Sang-Bong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.22-24
    • /
    • 2002
  • This paper introduces the real-time soil thermal property analyzer and temperature measuring system which is combined with radio telecommunication technique. To measure the thermal parameters in real-time, the radio telecommunication technique are used the personal communication service (PCS) which is in the world-wide serviced commercially firstly by CDMA. The thermal property analyzer has an ability of measuring thermal resistivity, thermal diffusivity and thermal stability. To estimate the soil thermal properties, the curve fitting algorithm by means of the least square method are used. TCP/IP protocol and MTM are used to install the real-time soil thermal property and temperature measurement system at multiple locations along routes of the underground power cables and to reduce the cost of telecommunication.

  • PDF

A study on the implementation of optical absorption spectrum analyzer for detecting gases in OF power cable (OF 케이블 Gas 검출을 위한 광흡수 스펙트럼 분석장치 구현에 관한 연구)

  • Oh, S.K.;Kang, D.S.;Kim, Y.H.;Kang, U.;Ryoo, H.S.;Park, H.S.;Roh, J.D.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2450-2452
    • /
    • 1999
  • Presently, it is now developing the optical remote gas sensor system which can measure combustible gases such as $CH_4$ and $C_2H_2$ generating by partial discharges inside the cable and connection parts to detect thermal deterioration of Oil-Filled (OF) power cable at the appropriate time. It is the most important parameter to select central wavelength of laser diode (LD) by analyzing the absorption bend of measuring gases in the infrared region. In this research, we proposed the optical spectrum analyzer to absorption band of $CH_4$ and $C_2H_2$ for the preliminary research of optical fiber gas detecting system.

  • PDF

Optics of Refractometers for Refractive Power Measurement of the Human Eye

  • Ko, Dong-Seob;Lee, Byeong-Ha
    • Journal of the Optical Society of Korea
    • /
    • v.10 no.4
    • /
    • pp.145-156
    • /
    • 2006
  • In the field of ophthalmology, many diagnostic instruments based on optical technology have been developed, such as refractometer, keratometer, corneal mapper, tonometer, fundus camera, slit lamp, laser scan ophthalmoscope and optical coherence tomography. Among them, the refractometer that is used for measuring the refractive power of the human eye has the long research history and various types have been developed. However the efforts to realize more accurate and precise measurement are still in progress. The wavefront analyzer commercialized in recent years is an excellent outcome of such efforts. In this paper, a brief account of the developmental history of various refractometers including the wavefront analyzer is summarized, and the underlying measurement principle is introduced in the view of optics. Finally, the technical issues that should be solved for getting better performance are discussed.

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

High-Frequency Equivalent Circuit Model for Differential Mode Noise Analysis of DC-DC Buck Converter (DC-DC 벅 컨버터의 차동모드 노이즈 분석을 위한 고주파 등가회로 모델)

  • Shin, Juhyun;Kim, Woojung;Cha, Hanju
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.6 no.4
    • /
    • pp.473-480
    • /
    • 2020
  • In this paper, we proposed a high frequency equivalent circuit considering parasitic impedance components for differential noise analysis on the input stage during DC-DC buck converter switching operation. Based on the proposed equivalent circuit model, we presented a method to measure parasitic impedance parameters included in DC bus plate, IGBT, and PCB track using the gain phase method of a network analyzer. In order to verify the validity of this model, a DC-DC prototype consisting of a buck converter, a signal analyzer, and a LISN device, and then resonance frequency was measured in the frequency range between 150 kHz and 30 MHz. The validity of the parasitic impedance measurement method and the proposed equivalent model is verified by deriving that the measured resonance frequency and the resonance frequency of the proposed high frequency equivalent model are the same.