• Title/Summary/Keyword: power absorption

Search Result 852, Processing Time 0.027 seconds

Fabrication of Cu2SnS3 (CTS) thin Film Solar Cells by Sulfurization of Sputtered Metallic Precursors (스퍼터법을 이용한 메탈 전구체기반의 Cu2SnS3 (CTS) 박막 태양전지 제조 및 특성 평가)

  • Lee, Ju Yeon;Kim, In Young;Minhao, Wu;Moon, Jong Ha;Kim, Jin Hyeok
    • Current Photovoltaic Research
    • /
    • v.3 no.4
    • /
    • pp.135-139
    • /
    • 2015
  • $Cu_2SnS_3$ (CTS) based thin film solar cells (TFSCs) are of great interest because of its earth abundant, low-toxic and eco-friendly material with high optical absorption coefficient of $10^4cm^{-1}$. In this study, the DC sputtered precursor thin films have been sulfurized using rapid thermal annealing (RTA) system in the graphite box under Ar gas atmosphere for 10 minute. The systematic variation of sulfur powder during annealing process has been carried out and their effects on the structural, morphological and optical properties of CTS thin films have been investigated. The preliminary power conversion efficiency of 1.47% with a short circuit current density of $33.9mA/cm^2$, an open circuit voltage of 159.7 mV, and a fill factor of 27% were obtained for CTS thin film annealed with 0.05g of S powder, although the processing parameter s have not yet been optimized.

Measurment of Gold Coating Thickness by PIXE (양성자 유발 X-선 발생법에 의한 금 박막의 두께 측정)

  • Kim, N.B.;Woo, H.J.;Kim, Y.S.;Kim, D.K.;Kim, J.K.;Choi, H.W.;Park, K.S.
    • Analytical Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.471-476
    • /
    • 1994
  • The capability of PIXE (Proton Induced X-ray Emission) method for the precision measurement of coating thickness has been tested by measuring several gold coated copper plates. Two different experimental methods are applied and compared. The results are compared with those by the weight measurement and proton RBS (Rutherford Backscattering Spectrometry). The advantage of the method is that it can be also used for the nondestructive thickness measurement of this layers on large-scaled samples or archeological samples which cannot be placed in a vacuum chamber.

  • PDF

The Comparison of Absolute Dose due to Differences of Measurement Condition and Calibration Protocols for Photon Beams (6MV 광자선에서 측정조건의 변화와 측정법의 차이에 의한 절대 선량값의 비교)

  • Kim, Hoi-Nam
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.10 no.1
    • /
    • pp.11-22
    • /
    • 1998
  • The absolute absorbed dose can be determined according to the measurement conditions ; measurement material, detector, energy and calibration protocols. The purpose of this study is to compare the absolute absorbed dose due to the differences of measurement condition and calibration protocols for photon beams. Dosimetric measurements were performed with a farmer type PTW and NEL ionization chambers in water, solid water, and polystyrene phantoms using 6MV photon beams from Siemens linear accelerator. Measurements were made along the central axis of $10{\times}10cm$ field size for constant target to surface distance of 100cm for water, solid water and polystyrene phantom. Theoretical absorbed dose intercomparisons between TG21 and IAEA protocol were performed for various measurement combinations on phantom, ion chamber, and electrometer. There were no significant differences of absorbed dose value between TG2l and IAEA protocol. The differences between two protocols are within $1\%\;while\;the\;average\;value\;of\;IAEA\;protocol\;was\;0.5\%$ smaller than TG2l protocol. For the purpose of comparison, all the relative absorbed dose were nomalized to NEL ion chamber with Keithley electrometer and water phantom, The average differences are within $1\%,\;but\;individual\;discrepancies\;are\;in\;the\;range\;of\;-2.5\%\;to\;1.2\%$ depending upon the choice of measurement combination. The largest discrepancy of $-25\%$ was observed when NEL ion chamber with Keithley electrometer is used in solid water phantom. The main cause for this discrepancy is due to the use of same parameters of stopping power, absorption coefficient, etc. as used in water phantom. It should be mentioned that the solid water phantom is not recommended for absolute dose calibration as the alternative of water, since absorbed dose show some dependency on phantom material other than water. In conclusion, the trend of variation was not much dependent on calibration protocol. However, It shows that absorbed dose could be affected by phantom material other than water.

  • PDF

Comparison of Pregnant Women's Mechanical Energy between the Period of Pregnancy and Postpartum (임신 기간 및 출산 후의 임산부 보행의 역학적 에너지 변화)

  • Hah, Chong-Ku;Yi, Jae-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.387-393
    • /
    • 2010
  • The purpose of this study was to compare pregnant women's gait parameters and mechanical energies caused by changes in hormone levels and anatomical features such as body mass, body-mass distribution, joint laxity, and musculo-tendinous strength from pregnancy to postpartum. Ten subjects (height: $161{\pm}6.5cm$, mass: $62.7{\pm}10.4\;kg$, $66.4{\pm}9.3\;kg$, $68.4{\pm}7.7\;kg$, $57.2{\pm}7.7\;kg$) participated in the four times experiments (the first, middle, last term and after birth) and walked ten trials at a self-selected pace without shoes. The gait motions were captured with Qualisys system and gait parameters were calculated with Visual-3D. Pregnant women's gait velocities were decreased during the pregnancy periods, but increased after birth. Stride width and cycle time were increased during pregnancy, but decreased after birth. Thigh energy (77.4%) was greater than shank energy (19.06%) or feet (3.54%) about total energy of the lower limbs. Their feet (Left R2=0.881, Right R2=0.852) and shank (Left R2=0.318, Right R2=0.226) energies were significantly increased (positive correlation), but double limb stance time (DLST, R2=0.679) and body total energy (R2=0.138) were decreased (negative correlation) for their velocities. These differences suggest that thigh segment may be a dominant segment among lower limbs, and have something to do with gait velocities. Further studies should investigate joint power and joint work to find energy dissipation or absorption from pregnancy period to postpartum.

Comparison of characteristics of IZO-Ag-IZO and IZO-Au-IZO multilayer electrodes for organic photovoltaics

  • Jeong, Jin-A;Choi, Kwang-Hyuk;Park, Yong-Seok;Park, Ho-Kyun;Kim, Han-Ki
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.131-131
    • /
    • 2010
  • We compared the electrical, optical, structural, and interface properties of indium zinc oxide (IZO)-Ag-IZO and IZO-Au-IZO multilayer electrodes deposited by linear facing target sputtering system at room temperature for organic photovoltaics. The IZO-Ag-IZO and IZO-Au-IZO multilayer electrodes show a significant reduction in their sheet resistance (4.15 and 5.49 Ohm/square) and resistivity ($3.9{\times}10^{-5}$ and $5.5{\times}10^{-5}$Ohm-cm) with increasing thickness of the Ag and Au layers, respectively. In spite of its similar electrical properties, the optical transmittance of the IZO-Ag-IZO electrode is much higher than that of the IZO-Au-IZO electrode, due to the more effective antireflection effect of Ag than Au in the visible region. In addition, the Auger electron spectroscopy depth profile results for the IZO/Ag/IZO and IZO/Au/IZO multilayer electrodes showed no interfacial reaction between the IZO layer and Ag or Au layer, due to the low preparation temperature. To investigate in detail the Ag and Au structures on the bottom IZO electrode with increasing thickness, a synchrotron x-ray scattering examination was employed. Moreover, the OSC fabricated on the IZO-Ag-IZO electrode shows a higher power conversion efficiency (3.05%) than the OSC prepared on the IZO-Au-IZO electrode (2.66%), due to its high optical transmittance in the wavelength range of 400-600 nm, which is the absorption wavelength of the P3HT:PCBM active layer.

  • PDF

A Study of Long Term Recording Reserved Type Material by Using Glass Micro-structure (유리의 미세구조를 이용한 장기보존형 기록재료에 관한 연구)

  • Lee, Kang-Taek;Yoon, Duk-Ki;Chin, Hyun-Ju;Choi, Kwang-Hoon;Lee, Kyu-Ho;Kim, Hyun-Gyu;Ryu, Bong-Ki
    • Korean Journal of Materials Research
    • /
    • v.16 no.12
    • /
    • pp.777-781
    • /
    • 2006
  • Recently, there are a lot of study to alternate polycarbonate which is being used as storage material in CD, DVD. In this study, we alternated polycarbonate with glass. We observed the change of shape in a surface of the glass which was focused by Nd:YAG Laser. The change of shape and property was studied by thermal mechanical analysis (TMA), UV-Vis spectrometer, AFM and SEM. According to Laser power and quantity of additives, the Bump's size and shape are showed differently. In high energy, the Bump will be transformed into Pit. And also according to CTE, $T_d$ and absorption ratio of glass, difference between Bump and Pit is confirmed. From these investigation, we could control that the minimum size of bump which is more useful shape than pit's is about 1.3 $\mu$m, H 70 nm, and it is near same the spot size.

Studies on Rheological Properties of Dough and Stability of Frozen Dough (밀가루의 이화학적(理化學的)인 성질(性質) 및 냉동(冷凍)반죽의 안정성(安定性))

  • Suh, Sook Chool;Song, Hyung lk;Chung, Ki Taek
    • Current Research on Agriculture and Life Sciences
    • /
    • v.5
    • /
    • pp.75-80
    • /
    • 1987
  • We investigated physico-chemical properties of hard wheat flours for frozen yeast-raised breadmaking and freezing stability of frozen dough prepared by the straight no-time method. The general Composition of wheat flours were : moisture ; 14.0%, ash ; 0.48%. protein ; 13.15%, and dry gluten ; 13.43%. In farinograph data, development time and water absorption were 5.5 mimutes and 62 %, respectively. Amylograph maximum viscosity was 500 BU. Resistance to extention increased with the time and their extensibility decreased in the extensigraph data. From these results obtained from these physico-chemical properties, it was confirmed that the used wheat flours were most suitable for bread-baking. Considering effect of gassing power on cold storage period and fermentation time, it was effective that dough temperature should be adjusted to $20^{\circ}C$ in order to decrease freezing injury and maintain freezing stability.

  • PDF

Consideration of the Direction for Improving RI-Biomics Information System for Using Big Data in Radiation Field (방사선 빅데이터 활용을 위한 RI-Biomics 기술정보시스템 개선 방향성에 관한 고찰)

  • Lee, Seung Hyun;Kim, Joo Yeon;Lim, Young-Khi;Park, Tai-Jin
    • Journal of Radiation Industry
    • /
    • v.11 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • RI-Biomics is a fusion technology in radiation fields for evaluating in-vivo dynamics such as absorption, distribution, metabolism and excretion (RI-ADME) of new drugs and materials using radioisotopes and quantitative evaluation of their efficacy. RI-Biomics information is being provided by RIBio-Info developed as information system for distributing its information and three requirements for improving RIBio-Info system have been derived through reviewing recent big data trends in this study. Three requirements are defined as resource, technology and manpower, and some reviews for applying big data in RIBio-In system are suggested. Fist, applicable external big data have to be obtained, second, some infrastructures for realizing applying big data to be expanded, and finally, data scientists able to analyze large scale of information to be trained. Therefore, an original technology driven to analyze for atypical and large scale of data can be created and this stated technology can contribute to obtain a basis to create a new value in RI-Biomics field.

The Effect of Incoherent Pumping in Electromagnetically Induced Absorption (전자기 유도 흡수에서의 비결맞음 펌핑 효과)

  • Moon, Han-Sub;Kim, Sook-Yung;Kim, Kyung-Dae;Lee, Chung-Hee;Lee, Rim;Kim, Haeng-Hwa;Kim, Joong-Bok
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.5
    • /
    • pp.449-454
    • /
    • 2002
  • We have studied the effects of incoherent pumping on EIA at the transition between the $F_g=2$ ground state and the $F_e=3$ excited state in $^{85}Rb\;D_1$-line. Generally, the studies about EIA have been done in the cycling transition, where the population has no loss to other states. In the case of EIA by using the $^{85}Rb\;D_1$ transition line, the population is transferred to the other hyperfine state due to optical pumping. We incoherently pumped the atoms from $F_g=3\;to\;F_g=2$ with the pumping beam, which is resonant at the transition from $F_g=3\;to\;F_g=2$. We were able to observe the effects of incoherent pumping depending on the power and the polarization of the pumping beam.

A Study on the Lifetime Estimation and Leakage Test of Rubber O-ring in Contacted with Fuel at Accelerated Thermal Aging Conditions (가속노화조건 하 연료접촉 고무오링의 수명예측 및 누유시험 연구)

  • Chung, Kunwoo;Hong, Jinsook;Kim, Young-wun;Han, Jeongsik;Jeong, Byunghun;Kwon, Youngil
    • Tribology and Lubricants
    • /
    • v.35 no.4
    • /
    • pp.222-228
    • /
    • 2019
  • As rubber products such as O-rings, which are also known as packings or toric joints, come in regular, long term contact with liquid fuel, they can eventually swell, become mechanically weakened, and occasionally crack; this diminishes both their usefulness and intrinsic lifetime and could cause leaks during the steady-state flow condition of the fuel. In this study, we evaluate the lifetime of such products through compression set tests of FKM, a family of fluorocarbon elastomer materials defined by the ASTM international standard D141; these materials have great compression, sunlight, and ozone resistance as well as a low gas absorption rate. In this process, O-rings are immersed in the liquid fuel of airtight containers that can be expressed as a compression set, and the liquid fuel leakage in a flow rig tester at variable temperatures over 12 months is investigated. Using the Power Law model, our study determined a theoretical O-ring lifetime of 2,647 years, i.e. a semi-permanent lifespan, by confirming the absence of liquid fuel leakage around the O-ring assembled fittings. These results indicate that the FKM O-rings are significantly compatible for fuel tests to evaluate long-term sealing conditions.