• Title/Summary/Keyword: power absorption

Search Result 852, Processing Time 0.024 seconds

Study on Wave Energy Generation of Multi-Floating Bodies for Energy Absorption by CFD

  • Li, Kui-Ming;Choi, Yoon-Hwan;Lee, Yeon-Won
    • Journal of Power System Engineering
    • /
    • v.17 no.5
    • /
    • pp.38-43
    • /
    • 2013
  • In order to design a wave energy generating system, a 6-DOF analysis technique is applied to CFD analysis on of a floating body and the behavior is interpreted according to the nature of the incoming waves. A spring constant is adopted to control the motion of multi floating bodies and to calculate the total average power absorption. Three cases of different wavelengths namely 20D, 30D and 40D have been modeled to analyze the total average power absorption. The average power absorption not only varies with the position of the floating body but also varies with wavelength. From the results obtained, it is concluded that the maximum total average power absorption is 9W approximately in wavelength 30D and the minimum total average power absorption is 4.3W approximately in wavelength 40D.

The Comparison of Absorption Characteristics between High Absorbent Polymers and Cellulose (고흡수성(高吸水性) Polymer와 Cellulose의 흡수특성(吸水特性) 비교(比較))

  • Yang, In;Ahn, Won-Yung
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.36-48
    • /
    • 1990
  • This experiment was carried out to improve the quality of high absorbent polymer which has excellent absorptivity and water retention compared to pulp and absorption sheet, through absorption characteristics-absorptive power, water retention, absorption rate, gel strength, pH, particle size, and moisture content. - of six polymers, namely, anionic polyacrylamide, cationic polyacrylamide, polyacrylic, acid polyvinyle alcohol 500, and 1500, and a-cellulose. and to examine the possibility of substitution of amide groups for carboxyl group and/or hydroxyl group which were commercial high absorbent polymer by comparing the absorption characteristics of the polymers. Polyacrylamide has high absorptive power and water retention, but has low gel strength and poor absorption rate. The rest of polymers were similiar to ${\alpha}$-cellulose in every respect. Thus, polyacrylamides could be replaced with polyacrylic acid and polyvinyl alcohol which are presently a high absorbent polymers. In comparing the absorption characteristics and the absorptive power of the polymers-anionic polyacrylamide, cationic polyacrylamide, polyacrylic acid, polyvinyle alcohol. a-cellulose-the absorptive power was in inverse proportion to the gel strength and absorption rates, affected by the particle size and pH change.

  • PDF

Modeling of Mixed Phosphors in White Light Emitting Diode (백색 발광다이오드에서의 혼합 형광체 모델링)

  • Kim, Dowoo;Gong, Dayeong;Gong, Myeongkook
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.7
    • /
    • pp.567-574
    • /
    • 2013
  • An optical model is proposed in the white LED using phosphor and LED chip. In this paper a new model that describes the absorption rate and quantum efficiency with increasing the mixing ratio of phosphor in silicone, and the allotment of the phosphor absorption optical power in the several phosphor mixing in the silicone. Single phosphor in silicone from the optical measurement data before and after molding, the solution to get the blue optical power and the phosphor emission optical power is proposed. By these solution the absorption rate and the quantum efficiency was obtained. The model with single phosphor mixing in the silicone the validity was confirmed.

Health prognostics of stator Windings in Water-Cooled Generator using Fick's second law (Fick's second law 를 이용한 수냉식 발전기 고정자 권선의 건전성 예지)

  • Youn, Byeng D.;Jang, Beom-Chan;Kim, Hee-Soo;Bae, Yong-Chae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.533-538
    • /
    • 2014
  • Power generator is one of the most important component of electricity generation system to convert mechanical energy to electrical energy. I t designed robustly to maintain high system reliability during operation time. But unexpected failure of the power generator could happen and it cause huge amount of economic and social loss. To keep it from unexpected failure, health prognostics should be carried out In this research, We developed a health prognostic method of stator windings in power generator with statistical data analysis and degradation modeling against water absorption. We divided whole 42 windings into two groups, absorption suspected group and normal group. We built a degradation model of absorption suspected winding using Fick's second law to predict upcoming absorption data. Through the analysis of data of normal group, we could figure out the distribution of data of normal windings. After that, we can properly predict absorption data of normal windings. With data prediction of two groups, we derived upcoming Directional Mahalanobis Distance (DMD) of absorption suspected winding and time vs DMD curve. Finally we drew the probability distribution of Remaining Useful Life of absorption suspected windings.

  • PDF

RF Power Absorption Enhancement of Magnetic Composites with Conductive Grid

  • Nam, Baek-Il;Kim, Jin-U;Kim, Ki-Hyeon
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.129-132
    • /
    • 2012
  • To evaluate the electromagnetic power absorption in near field, the magnetic composites with the conductive grids were simulated using the typical permeability frequency profiles. The transmission power absorptions of the magnetic composites on microstrip line were extracted by the 3D FEM simulation program of HFSS. The magnitudes of power absorptions were greatly enhanced up to 98% and broadened the absorbing frequency band over 5 GHz by the insertion of a conductive grid in magnetic composite. The initial frequency of the power absorption can controlled by the change of the ferromagnetic resonance frequencies of the magnetic composite.

An Experimental Study on Water Absorbtion Characteristics of Generator Stator Bar Insulation by Cooling Water Temperature in 500MW Capacity Power Plant (500MW급 화력 발전기 냉각수 온도에 따른 고정자 권선 절연재의 흡습 특성에 관한 실험적 연구)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1392-1397
    • /
    • 2008
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. De-mineralized water is used to cool stator bars during the normal operation of generator in large power plants because the water cooled method has highest cooling efficient. Water absorption of bar insulation is progressed by several causes such as generation of water leak path by corrosion, delamination of insulation by vibration, and inadequate water treatment, etc.. Reliable water absorption diagnostics of generator stator bar is important to ensure the availability of power plant and to reduce maintenance cost by generator accident. It is described that the water absorption characteristics for generator stator bar insulation used in 500MW capacity standard fossil power plant by cooling water temperature. It is verified that the management of stator cooling water temperature is one of the important factors to decrease water absorption rate of generator stator bars.

Theoretical Modeling of the Internal Power Flow and Absorption Loss of the Air Mode Based on the Proposed Poynting Vector Analysis in Top-emitting Organic Light-emitting Diodes

  • Kim, Jiyong;Kim, Jungho;Kim, Kyoung-Youm
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1663-1674
    • /
    • 2018
  • We propose the Poynting vector analysis of the air mode in a top-emitting organic light-emitting diode (OLED) by combining the transfer matrix method and dipole source term. The spatial profiles of the time-averaged optical power flow of the air mode are calculated inside and outside the multilayer structure of the OLED with respect to the thickness of the semi-transparent top cathode and capping layer (CPL). We elucidate how the micro-cavity effect controlled by the thickness variation of the semi-transparent top cathode or CPL affects the internal optical power and absorption loss inside the OLED multilayer and the external optical power coupled into the air. When the calculated absorption loss and external power obtained by the proposed Poynting vector and currently-used point dipole models are compared, two calculation results are identical, which demonstrates the validity of the two models.

Efficiency Analysis of a Wave Power Generation System by Using Multibody Dynamics (다물체동역학을 이용한 다자유도 파력발전시스템의 흡수 효율 분석)

  • Kim, Min Soo;Sohn, Jeong Hyun;Kim, Jung Hee;Sung, Yong Jun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.6
    • /
    • pp.557-563
    • /
    • 2016
  • The energy absorption efficiency of a wave power generation system is calculated as the ratio of the wave power to the power of the system. Because absorption efficiency depends on the dynamic behavior of the wave power generation system, a dynamic analysis of the wave power generation system is required to estimate the energy absorption efficiency of the system. In this study, a dynamic analysis of the wave power generation system under wave loads is performed to estimate the energy absorption efficiency. RecurDyn is employed to carry out the dynamic analysis of the system, and the Morison equation is used for the wave load model. According to the results, the lower the wave height and the shorter the period, the higher is the absorption efficiency of the system.

Effect of SiO2 Antireflection Coating on the Si Solar Cell (Si 태양전지에서 SiO2 광반사 방지막의 처리 효과)

  • Chang Gee-Keun;Lim Yong-Keu;Hwang Yong-Woon;Cho Jae-Uk
    • Korean Journal of Materials Research
    • /
    • v.14 no.2
    • /
    • pp.152-156
    • /
    • 2004
  • We have studied the effective optical absorption power of Si solar cell with $SiO_2$-antireflection layer based on a mathematical modelling of AM(air mass)1 spectrum and Si refractive index in the wavelength range(0.4 $\mu\textrm{m}\leq$λ$\leq$$0.97\mu\textrm{m}$). The effective optical absorption power obtained from the theoretical calculation was 450 and 520 W/$\m^2$ for the Si solar cells with $SiO_2$-antireflection layer of 500$\AA$ and 1000$\AA$, respectively. The optimum thickness of $SiO_2$-antireflection layer showing the minimum reflection loss was about 1000$\AA$ in the computer simulation. Two kinds of Si solar cells named EBS(500$\AA$) and EBS(l000$\AA$) were fabricated to evaluate the effect of $SiO_2$-antireflection layer thickness on the optical absorption. The epitaxial base Si cell with $SiO_2$-antireflection layer of 1000$\AA$ [EBS(l000$\AA$)] showed the output power improvement of about 15% upon the EBS(500$\AA$) cell due to larger absorption of effective optical power under illumination of AM1, 1 sun.

Water Absorption Sensor of Generator Stator Bar Insulation using Cross Capacitance (크로스 커패시턴스를 이용한 발전기 고정자 권선 절연물 흡습 측정 센서)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Doo-Young;Lee, Wook-Ryun;Lee, Rae-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.10
    • /
    • pp.1972-1977
    • /
    • 2011
  • The mechanical integrity of generator stator windings is one of the critical point because the electric power is generated and conducted to power system through these windings. To cool down the heat emitted from generator winding during its operation, a majority of generators use de-mineralized water characterized by high cooling efficiency. Contrary to such the excellent cooling efficiency, however, the damaged bar insulations attributed to the absorption of cooling water in the generator stator winding lead to highly time- and cost consuming efforts as well as to service deterioration due to unexpected forced outage of generator. It is described that the new design of water absorption sensor using cross capacitance for generator in power plant in order to increase the reliability of water absorption diagnostics for generator stator bar insulation.