• 제목/요약/키워드: potable water

검색결과 120건 처리시간 0.021초

POTABLE WATER TREATMENT BY POLYACRYLAMIDE BASE FLOCCULANTS, COUPLED WITH AN INORGANIC COAGULANT

  • Bae, Young-Han;Kim, Hyung-Jun;Lee, Eun-Joo;Sung, Nak-Chang;Lee, Sung-Sik;Kim, Young-Han
    • Environmental Engineering Research
    • /
    • 제12권1호
    • /
    • pp.21-29
    • /
    • 2007
  • For this study, we polymerized polyacrylamide base flocculants (PAA) and tested their properties and settling efficiency as a treatment for potable water. The most common chemicals for potable water treatment in Korea are alum or PAC. However, due to various reasons (such as rainy season or algae), inorganic flocculants cannot be solely depended on to solve all the problems caused by the poor quality of inflow water. When PAA coupled with coagulants in a potable water purification process is used, the turbidity removal efficiency increases by a factor of three on a single chemical system using PAC (Raw water: 5.21 NTU; Treated PAA+PAC: 0.34 NTU; and, Treated PAC: 1.04 NTU). It is possible to offset the toxic effect of residual monomers in treated water using PAA, because the concentrations of residual acrylamide are less than 400 mg/L in the polymer itself and less than $0.04\;{\mu}g/L$ in the treated water base at a dosage of 0.1 mg/L. Therefore, PAAs may be a workable, and dependable, potable water treatment process for the high pollutant level of resource water.

Model based control of filter run time on potable water treatment plant

  • Jusic, Suvada;Milasinovic, Zoran
    • Coupled systems mechanics
    • /
    • 제4권2호
    • /
    • pp.157-172
    • /
    • 2015
  • Control of potable water treatment plant (PWTP) is nowadays based on experience. The aim of this article is to show that model based control of treatment process is more efficient than process operation based on experience. Stimela environment is used for modeling of processes of potable water treatment. Application of the model was conducted on PWTP "Crkvice" in Zenica (BiH). This plant has used conventional rapid sand filters. By effective application of the model it is determined the optimal filter run time for different input turbidity of raw water. This results in the possibility of reducing the consumption of backwashing water, lower costs for its pumping and reducing the amount of coagulants. In the existing practice, based on experience, these benefits are not used.

다중수원을 활용한 멀티워터 루프시스템의 표준화방안 구축에 관한 연구 (A Study on Standardization Method Establishment of Multi Water-Loop System using Multi Water Resources)

  • 이현동;이준형;곽필재
    • 한국관개배수논문집
    • /
    • 제21권1호
    • /
    • pp.109-117
    • /
    • 2014
  • Multi water-loop system is the efficient customer centered facilities of water supply by utilizing the multi water resources. Multi water-loop system is divided into various types. The system is classified potable and non-potable type. Mostly, the potable type utilizes surface water and ground water. However, the non-potable type utilize the multi water resources, such as rain water, sea water, reclaimed water, etc. Selective intake is possible when characteristics of region, physiographic condition and purpose of use are considered. For instance, downtown type, new-city type, agriculture type, island type are available. For development and application of these multi water-loop system, standardization is needed. For standardization, several methods are given; design principles, selection and composition method of multi water-loop system structure, BIM/GIS application method, safety inspection method. Consequently, a road map of design standardization method can be established. In this road map, there are three parts for the standardization of multi water-loop system. Three parts are the considerations, base material and ways of standardization. Design standardization become close when this road map followed by someone who plan the multi water-loop system. In this way, loop system's development is more efficient and economic. In hereafter research, each type's characteristic will be analysed and standardization methods can be established.

  • PDF

물에 대한 새로운 평가 (The New Evaluation Basis of Potable Water)

  • 문승주
    • 기술사
    • /
    • 제35권4호
    • /
    • pp.24-28
    • /
    • 2002
  • For a long time, we use the chemical analysis only for the evaluation of potable water. but recently water which Is good or not for the vital body should be proposed to take additional new evaluation technology Nuclear Magnetic Resonance(NMR). The optimum value of NMR data should be below 100Hz of Half width.

  • PDF

Iron and manganese removal in direct anoxic nanofiltration for indirect potable reuse

  • Jin, Yongxun;Choi, Yeseul;Song, Kyung Guen;Kim, Soyoun;Park, Chanhyuk
    • Membrane and Water Treatment
    • /
    • 제10권4호
    • /
    • pp.299-305
    • /
    • 2019
  • Managed aquifer recharge (MAR) systems are gaining interest as an alternative to conventional water resources. However, when the water recovered in MAR systems, dissolved iron and manganese species may easily oxidize and they cause well screen clogging or require abandonment of extraction wells. In this study, both oxic and anoxic conditions were analyzed to verify the feasibility of the membrane filtration performance under various solution chemistries. The fouling mechanisms of the metal ions under anoxic conditions were also investigated by employing synthetic wastewater. The fouled membranes were then further analyzed to verify the major causes of inorganic fouling through SEM and XPS. The newly suggested anoxic process refining existing membrane process is expected to provide more precious information about nanofiltration (NF) membrane fouling, especially for demonstrating the potential advantages to chemical-free drinking water production for indirect potable reuse.

농촌지역 간이상수도 수질에 대한 수리지화학적 특성: 충남 금산군 일대

  • 이진수;고경석;김용재
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2004년도 임시총회 및 추계학술발표회
    • /
    • pp.369-372
    • /
    • 2004
  • This study presents the hydrogeochmical investigation to know the effect of geology and sources for water quality in small potable water supply system at rural area. The results of water quality in Geumsan area showed the 3.2% of water samples exceeded the limit of drinking water standard by bacteria. The hydrochemical investigation results indicated the high EC, Ca and HCO$_3$ in surface water and metasedimentary rocks and this is caused by the dissolution of calc-slicate minerals of metasedimentary rocks.

  • PDF

Solar power and desalination plant for copper industry: improvised techniques

  • Sankar, D.;Deepa, N.;Rajagopal, S.;Karthik, K.M.
    • Advances in Energy Research
    • /
    • 제3권1호
    • /
    • pp.59-70
    • /
    • 2015
  • In India, continuous production of electricity and sweet/potable water from Solar power and desalination plant plays a major role in the industries. Particularly in Copper industry, Solar power adopts Solar field collector combined with thermal storage system and steam Boiler, Turbine & Generator (BTG) for electricity production and desalination plant adopts Reverse osmosis (RO) for sweet/potable water production which cannot be used for long hours of power generation and consistency of energy supply for industrial processes and power generation cannot be ensured. This paper presents an overview of enhanced technology for Solar power and Desalination plant for Copper industry making it continuous production of electricity and sweet/potable water. The conventional technology can be replaced with this proposed technique in the existing and upcoming industries.

휴대용 유출기름회수기의 개발(II) - 공기흡입회수기의 제작과 성능시험 (Development of a Potable Skimmer(II) - Fabrication and Performance Test of an Air Suction Skimmer)

  • 박외철
    • 한국환경과학회지
    • /
    • 제3권2호
    • /
    • pp.177-184
    • /
    • 1994
  • An air suction skimmer was selected as a potable skimmer to be developed among the many reviewed skimmers because of its advantages such as simple structure, excellent transportability, and easy deployment. A prototype of the skimmer was fabricated. It was shown that the skimmer operated by a commercial vacuum cleaner has good performance. The maximum suction rate of water and the maximum suction head were 18$m^3$/hr and 2.7m, respectively.

  • PDF

A STUDY ON THE ELIMINATION OF FLUORIDE IN A HOT SPRING WATER

  • Lee, Hyeon-Ki;Kim, Hwan-Gi
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.77-83
    • /
    • 2006
  • The hot spring water of the north Jeonla province such as Wanggung, Jookrim, Seokjung, and Hwasim, has fluoride concentration of 3.9 mg/L, 12.7 mg/L, 1.9 mg/L, and 6.3 mg/L, respectively. These figures fairly exceed the Korean and WHO standard for potable water, which is 1.5 mg/L. Therefore, in this study, research on elimination of fluoride in a hot spring water of Jookrim region, which has the highest level of fluoride concentration level in the north Jeonla province, was carried out. In analysis of Jookrim hot spring water according to the water quality standard for potable water, pH was very high at 9.25 and the concentration of fluoride was 10 times higher than the standard at 18.2 mg/L. Other measurements were within the standard or not detected. After injecting 10g of activated carbon for elimination of fluoride, the fluoride concentration was measured at 13.5 mg/L, and when 70mL or more of alum 10 g/L solution was injected, the concentration was measured at 2.8 mg/L, and injecting 3g of lime was measured at 9 mg/L. Alum showed the best elimination performance among all individual injections. Injection of 25 mL of activated carbon and 100 mL of alum solution together reduced the fluoride concentration down to 1.3 mg/L, which is under the potable standard. Injection of lime 1g and 75 mL of alum 10 g/L solution together reduced fluoride concentration to 4.1 mg/L. From the modifying HRT, by using ion exchange resin column, the pH was stabilized when HRT was Imin and showed range of $6.7{\sim}7.8$. The fluoride concentration reduced gradually as the HRT increased, and satisfied the potable standard when HRT passed 6 min, and after 30 min HRT, the concentration of fluoride was 0.05 mg/L: almost eliminated.

Community-acquired Legionnaires' Disease in a Newly Constructed Apartment Building

  • Ryu, Sukhyun;Yang, Kyungho;Chun, Byung Chul
    • Journal of Preventive Medicine and Public Health
    • /
    • 제50권4호
    • /
    • pp.274-277
    • /
    • 2017
  • Objectives: Legionnaires' disease (LD) is a severe type of pneumonia caused by inhalation of aerosols contaminated with Legionella. On September 22, 2016, a single case of LD was reported from a newly built apartment building in Gyeonggi province. This article describes an epidemiologic investigation of LD and identification of the possible source of infection. Methods: To identify the source of LD, we interviewed the patient's husband using a questionnaire based on the Legionella management guidelines from the Korea Centers for Disease Control and Prevention. Water samples from the site were collected and analyzed. An epidemiological investigation of the residents and visitors in the apartment building was conducted for 14 days before the index patient's symptoms first appeared to 14 days after the implementation of environmental control measures. Results: Legionella pneumophila serogroup 1 was isolated from the heated-water samples from the patient's residence and the basement of the apartment complex. Thirty-two suspected cases were reported from the apartment building during the surveillance period, yet all were confirmed negative based on urinary antigen tests. Conclusions: The likely source of infection was the building's potable water, particularly heated water. Further study of effective monitoring systems in heated potable water should be considered.